{"title":"Intramedullary Plating of Complex Proximal Humerus Fractures: A Case Series.","authors":"Stephen Mc Donald, Andrel Yoong, Piotr Skrzypiec, Alan Johnstone","doi":"10.22038/ABJS.2024.74258.3437","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To assess fracture union rates using novel intramedullary plate technique. Post-operative humeral neck-shaft angles, patient range of motion and complication profile were secondary outcomes of interest.</p><p><strong>Methods: </strong>Single surgeon, retrospective case series of surgical technique at major trauma centre in Scotland. A 2.0mm mini-fragment plate was secured to the humeral head to act as an intramedullary strut during fixation in complex proximal humerus fractures. Fracture union and neck-shaft angle were assessed radiologically, whilst range of motion and complication profiles were assessed clinically.</p><p><strong>Results: </strong>Twelve patients were followed up for an average of 10 months post-operatively. All achieved bony union with a mean neck-shaft angle of 128°. Mean range of motion values were 100° forward elevation, 83° abduction, 60° internal rotation and 37° external rotation. Four patients required further surgical intervention- two for hardware prominence, one for adhesive capsulitis and one for subsequent rotator cuff failure. There were no cases of avascular necrosis or infection.</p><p><strong>Conclusion: </strong>This novel technique addresses the established biomechanical propensity of proximal humerus fractures to fail in varus collapse and screw cut-out. This method provides an alternative to arthroplasty in the most severe proximal humerus fractures and is readily adopted via standard orthopaedic kit.</p>","PeriodicalId":46704,"journal":{"name":"Archives of Bone and Joint Surgery-ABJS","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11195036/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Bone and Joint Surgery-ABJS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22038/ABJS.2024.74258.3437","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To assess fracture union rates using novel intramedullary plate technique. Post-operative humeral neck-shaft angles, patient range of motion and complication profile were secondary outcomes of interest.

Methods: Single surgeon, retrospective case series of surgical technique at major trauma centre in Scotland. A 2.0mm mini-fragment plate was secured to the humeral head to act as an intramedullary strut during fixation in complex proximal humerus fractures. Fracture union and neck-shaft angle were assessed radiologically, whilst range of motion and complication profiles were assessed clinically.

Results: Twelve patients were followed up for an average of 10 months post-operatively. All achieved bony union with a mean neck-shaft angle of 128°. Mean range of motion values were 100° forward elevation, 83° abduction, 60° internal rotation and 37° external rotation. Four patients required further surgical intervention- two for hardware prominence, one for adhesive capsulitis and one for subsequent rotator cuff failure. There were no cases of avascular necrosis or infection.

Conclusion: This novel technique addresses the established biomechanical propensity of proximal humerus fractures to fail in varus collapse and screw cut-out. This method provides an alternative to arthroplasty in the most severe proximal humerus fractures and is readily adopted via standard orthopaedic kit.

复杂肱骨近端骨折的髓内置换术:病例系列
目的评估使用新型髓内钢板技术的骨折愈合率。术后肱骨颈轴角度、患者活动范围和并发症情况是次要关注结果:方法:苏格兰主要创伤中心的单个外科医生手术技术回顾性病例系列。在肱骨近端复杂骨折的固定过程中,将一块2.0毫米的微型钢板固定在肱骨头,作为髓内支柱。对骨折愈合和颈轴角进行放射学评估,对活动范围和并发症情况进行临床评估:对12名患者进行了平均10个月的术后随访。所有患者都实现了骨性结合,平均颈轴角为 128°。平均活动范围为前抬 100°、外展 83°、内旋 60°、外旋 37°。四名患者需要进一步手术治疗--两名患者因硬件突出而需要手术,一名患者因粘连性关节囊炎而需要手术,一名患者因后续肩袖功能衰竭而需要手术。没有出现血管坏死或感染病例:这项新技术解决了肱骨近端骨折在曲折塌陷和螺钉切出时失败的生物力学倾向。这种方法为最严重的肱骨近端骨折患者提供了关节置换术的替代方案,并可通过标准骨科工具包随时采用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.30
自引率
0.00%
发文量
128
期刊介绍: The Archives of Bone and Joint Surgery (ABJS) aims to encourage a better understanding of all aspects of Orthopedic Sciences. The journal accepts scientific papers including original research, review article, short communication, case report, and letter to the editor in all fields of bone, joint, musculoskeletal surgery and related researches. The Archives of Bone and Joint Surgery (ABJS) will publish papers in all aspects of today`s modern orthopedic sciences including: Arthroscopy, Arthroplasty, Sport Medicine, Reconstruction, Hand and Upper Extremity, Pediatric Orthopedics, Spine, Trauma, Foot and Ankle, Tumor, Joint Rheumatic Disease, Skeletal Imaging, Orthopedic Physical Therapy, Rehabilitation, Orthopedic Basic Sciences (Biomechanics, Biotechnology, Biomaterial..).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信