{"title":"Full operating parameter recording as an essential component of the reproducibility of laser-tissue interaction and treatments.","authors":"Steven Parker, Kinga Grzech-Leśniak, Mark Cronshaw, Jacek Matys, Aldo Brugnera Jr, Samir Nammour","doi":"10.17219/acem/189795","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The number and diversity of published peer-reviewed studies in the discipline of laser dentistry have grown considerably during the past 10 years.</p><p><strong>Objectives: </strong>Within primary research, the development of protocols to guide and formulate clinical practice demands precision and ease of reproducibility. Errors in data acquisition and management may become amplified as the applied randomized clinical trials (RCTs) forge new levels of clinical diversity and predictability in the use of laser photonic energy in both ablative (surgical) and sub-ablative (photobiomodulation (PBM) or photodynamic therapy (PDT)) applications.</p><p><strong>Material and methods: </strong>A comprehensive range of empirical and computational operating parameters must be included in published studies to facilitate the uniformity of powerand time-related values of laser irradiation.</p><p><strong>Results: </strong>Choosing the correct \"tissue irradiation parameters\" is difficult and depends on the pathology and symptoms, the surface area to be treated, laser wavelength, the thermal relaxation time of each targeted tissue, and controlling penetration depth of the light into tissues. Therefore, to allow the reproducibility of the results, it is recommended that authors mention with the greatest care and clarity the irradiation parameters used in their study.</p><p><strong>Conclusion: </strong>This paper outlines the concerns felt regarding the general shortfalls and proposes a minimum range of laser operating parameters that should be represented in future peer-reviewed publications.</p>","PeriodicalId":7306,"journal":{"name":"Advances in Clinical and Experimental Medicine","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Clinical and Experimental Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.17219/acem/189795","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The number and diversity of published peer-reviewed studies in the discipline of laser dentistry have grown considerably during the past 10 years.
Objectives: Within primary research, the development of protocols to guide and formulate clinical practice demands precision and ease of reproducibility. Errors in data acquisition and management may become amplified as the applied randomized clinical trials (RCTs) forge new levels of clinical diversity and predictability in the use of laser photonic energy in both ablative (surgical) and sub-ablative (photobiomodulation (PBM) or photodynamic therapy (PDT)) applications.
Material and methods: A comprehensive range of empirical and computational operating parameters must be included in published studies to facilitate the uniformity of powerand time-related values of laser irradiation.
Results: Choosing the correct "tissue irradiation parameters" is difficult and depends on the pathology and symptoms, the surface area to be treated, laser wavelength, the thermal relaxation time of each targeted tissue, and controlling penetration depth of the light into tissues. Therefore, to allow the reproducibility of the results, it is recommended that authors mention with the greatest care and clarity the irradiation parameters used in their study.
Conclusion: This paper outlines the concerns felt regarding the general shortfalls and proposes a minimum range of laser operating parameters that should be represented in future peer-reviewed publications.
期刊介绍:
Advances in Clinical and Experimental Medicine has been published by the Wroclaw Medical University since 1992. Establishing the medical journal was the idea of Prof. Bogumił Halawa, Chair of the Department of Cardiology, and was fully supported by the Rector of Wroclaw Medical University, Prof. Zbigniew Knapik. Prof. Halawa was also the first editor-in-chief, between 1992-1997. The journal, then entitled "Postępy Medycyny Klinicznej i Doświadczalnej", appeared quarterly.
Prof. Leszek Paradowski was editor-in-chief from 1997-1999. In 1998 he initiated alterations in the profile and cover design of the journal which were accepted by the Editorial Board. The title was changed to Advances in Clinical and Experimental Medicine. Articles in English were welcomed. A number of outstanding representatives of medical science from Poland and abroad were invited to participate in the newly established International Editorial Staff.
Prof. Antonina Harłozińska-Szmyrka was editor-in-chief in years 2000-2005, in years 2006-2007 once again prof. Leszek Paradowski and prof. Maria Podolak-Dawidziak was editor-in-chief in years 2008-2016. Since 2017 the editor-in chief is prof. Maciej Bagłaj.
Since July 2005, original papers have been published only in English. Case reports are no longer accepted. The manuscripts are reviewed by two independent reviewers and a statistical reviewer, and English texts are proofread by a native speaker.
The journal has been indexed in several databases: Scopus, Ulrich’sTM International Periodicals Directory, Index Copernicus and since 2007 in Thomson Reuters databases: Science Citation Index Expanded i Journal Citation Reports/Science Edition.
In 2010 the journal obtained Impact Factor which is now 1.179 pts. Articles published in the journal are worth 15 points among Polish journals according to the Polish Committee for Scientific Research and 169.43 points according to the Index Copernicus.
Since November 7, 2012, Advances in Clinical and Experimental Medicine has been indexed and included in National Library of Medicine’s MEDLINE database. English abstracts printed in the journal are included and searchable using PubMed http://www.ncbi.nlm.nih.gov/pubmed.