{"title":"Short-term outcomes of robotic subxiphoid-optical thymectomy.","authors":"Masanori Shimomura, Satoru Okada, Tatsuo Furuya, Rina Oya, Yuka Hirakawa, Fumimasa Amaya, Masayoshi Inoue","doi":"10.1007/s00595-024-02887-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the usefulness of robotic subxiphoid-optical thymectomy (RST).</p><p><strong>Methods: </strong>Thirty-seven procedures (thymoma, n = 19; thymic carcinoma, n = 1; myasthenia gravis, n = 3; and others, n = 14) performed between October 2020 and December 2023 were included. The right and left 6th intercostal midclavicular lines and subxiphoid, with an assistant port placed in the right third intercostal anterior axillary line, were adapted. Postoperative pain was assessed using a numerical rating scale (NRS).</p><p><strong>Results: </strong>A good view of the surgical field is obtained. The median console time was 113 min and the time to roll-in was 30 min. The body mass index (BMI) was 21.6. One patient with thymic carcinoma required combined resection of the left phrenic nerve and left brachiocephalic vein without conversion to thoracotomy, and 1 patient had post-pericardiotomy syndrome with bilateral pleural effusion. There was a correlation between the prolonged time to roll-in and BMI (ρ = 0.439; p = 0.007). Pain was controlled with oral medication on postoperative day 1 and significantly decreased at discharge and at the first outpatient visit without epidural anesthesia (median NRS scores: 4, 1, and 1, respectively).</p><p><strong>Conclusion: </strong>RST is a safe procedure that provides surgeons with a sufficient view of the anterior mediastinum and causes minimal postoperative pain.</p>","PeriodicalId":22163,"journal":{"name":"Surgery Today","volume":" ","pages":"205-210"},"PeriodicalIF":1.7000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgery Today","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00595-024-02887-x","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/24 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To evaluate the usefulness of robotic subxiphoid-optical thymectomy (RST).
Methods: Thirty-seven procedures (thymoma, n = 19; thymic carcinoma, n = 1; myasthenia gravis, n = 3; and others, n = 14) performed between October 2020 and December 2023 were included. The right and left 6th intercostal midclavicular lines and subxiphoid, with an assistant port placed in the right third intercostal anterior axillary line, were adapted. Postoperative pain was assessed using a numerical rating scale (NRS).
Results: A good view of the surgical field is obtained. The median console time was 113 min and the time to roll-in was 30 min. The body mass index (BMI) was 21.6. One patient with thymic carcinoma required combined resection of the left phrenic nerve and left brachiocephalic vein without conversion to thoracotomy, and 1 patient had post-pericardiotomy syndrome with bilateral pleural effusion. There was a correlation between the prolonged time to roll-in and BMI (ρ = 0.439; p = 0.007). Pain was controlled with oral medication on postoperative day 1 and significantly decreased at discharge and at the first outpatient visit without epidural anesthesia (median NRS scores: 4, 1, and 1, respectively).
Conclusion: RST is a safe procedure that provides surgeons with a sufficient view of the anterior mediastinum and causes minimal postoperative pain.
期刊介绍:
Surgery Today is the official journal of the Japan Surgical Society. The main purpose of the journal is to provide a place for the publication of high-quality papers documenting recent advances and new developments in all fields of surgery, both clinical and experimental. The journal welcomes original papers, review articles, and short communications, as well as short technical reports("How to do it").
The "How to do it" section will includes short articles on methods or techniques recommended for practical surgery. Papers submitted to the journal are reviewed by an international editorial board. Field of interest: All fields of surgery.