Listening Effort Measured With Pupillometry in Cochlear Implant Users Depends on Sound Level, But Not on the Signal to Noise Ratio When Using the Matrix Test.
IF 2.6 2区 医学Q1 AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY
Hendrik Christiaan Stronks, Annemijn Laura Tops, Kwong Wing Quach, Jeroen Johannes Briaire, Johan Hubertus Maria Frijns
{"title":"Listening Effort Measured With Pupillometry in Cochlear Implant Users Depends on Sound Level, But Not on the Signal to Noise Ratio When Using the Matrix Test.","authors":"Hendrik Christiaan Stronks, Annemijn Laura Tops, Kwong Wing Quach, Jeroen Johannes Briaire, Johan Hubertus Maria Frijns","doi":"10.1097/AUD.0000000000001529","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>We investigated whether listening effort is dependent on task difficulty for cochlear implant (CI) users when using the Matrix speech-in-noise test. To this end, we measured peak pupil dilation (PPD) at a wide range of signal to noise ratios (SNR) by systematically changing the noise level at a constant speech level, and vice versa.</p><p><strong>Design: </strong>A group of mostly elderly CI users performed the Dutch/Flemish Matrix test in quiet and in multitalker babble at different SNRs. SNRs were set relative to the speech-recognition threshold (SRT), namely at SRT, and 5 and 10 dB above SRT (0 dB, +5 dB, and +10 dB re SRT). The latter 2 conditions were obtained by either varying speech level (at a fixed noise level of 60 dBA) or by varying noise level (with a fixed speech level). We compared these PPDs with those of a group of typical hearing (TH) listeners. In addition, listening effort was assessed with subjective ratings on a Likert scale.</p><p><strong>Results: </strong>PPD for the CI group did not significantly depend on SNR, whereas SNR significantly affected PPDs for TH listeners. Subjective effort ratings depended significantly on SNR for both groups. For CI users, PPDs were significantly larger, and effort was rated higher when speech was varied, and noise was fixed for CI users. By contrast, for TH listeners effort ratings were significantly higher and performance scores lower when noise was varied, and speech was fixed.</p><p><strong>Conclusions: </strong>The lack of a significant effect of varying SNR on PPD suggests that the Matrix test may not be a feasible speech test for measuring listening effort with pupillometric measures for CI users. A rating test appeared more promising in this population, corroborating earlier reports that subjective measures may reflect different dimensions of listening effort than pupil dilation. Establishing the SNR by varying speech or noise level can have subtle, but significant effects on measures of listening effort, and these effects can differ between TH listeners and CI users.</p>","PeriodicalId":55172,"journal":{"name":"Ear and Hearing","volume":null,"pages":null},"PeriodicalIF":2.6000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11486951/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ear and Hearing","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/AUD.0000000000001529","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/18 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: We investigated whether listening effort is dependent on task difficulty for cochlear implant (CI) users when using the Matrix speech-in-noise test. To this end, we measured peak pupil dilation (PPD) at a wide range of signal to noise ratios (SNR) by systematically changing the noise level at a constant speech level, and vice versa.
Design: A group of mostly elderly CI users performed the Dutch/Flemish Matrix test in quiet and in multitalker babble at different SNRs. SNRs were set relative to the speech-recognition threshold (SRT), namely at SRT, and 5 and 10 dB above SRT (0 dB, +5 dB, and +10 dB re SRT). The latter 2 conditions were obtained by either varying speech level (at a fixed noise level of 60 dBA) or by varying noise level (with a fixed speech level). We compared these PPDs with those of a group of typical hearing (TH) listeners. In addition, listening effort was assessed with subjective ratings on a Likert scale.
Results: PPD for the CI group did not significantly depend on SNR, whereas SNR significantly affected PPDs for TH listeners. Subjective effort ratings depended significantly on SNR for both groups. For CI users, PPDs were significantly larger, and effort was rated higher when speech was varied, and noise was fixed for CI users. By contrast, for TH listeners effort ratings were significantly higher and performance scores lower when noise was varied, and speech was fixed.
Conclusions: The lack of a significant effect of varying SNR on PPD suggests that the Matrix test may not be a feasible speech test for measuring listening effort with pupillometric measures for CI users. A rating test appeared more promising in this population, corroborating earlier reports that subjective measures may reflect different dimensions of listening effort than pupil dilation. Establishing the SNR by varying speech or noise level can have subtle, but significant effects on measures of listening effort, and these effects can differ between TH listeners and CI users.
期刊介绍:
From the basic science of hearing and balance disorders to auditory electrophysiology to amplification and the psychological factors of hearing loss, Ear and Hearing covers all aspects of auditory and vestibular disorders. This multidisciplinary journal consolidates the various factors that contribute to identification, remediation, and audiologic and vestibular rehabilitation. It is the one journal that serves the diverse interest of all members of this professional community -- otologists, audiologists, educators, and to those involved in the design, manufacture, and distribution of amplification systems. The original articles published in the journal focus on assessment, diagnosis, and management of auditory and vestibular disorders.