Sydney M Todorovich, Kristine Van Aarsen, Shane R Freeman, Adam Slomer, Frank Myslik
{"title":"3M™ Defib-Pads as a Reusable Alternative to Commercial Ultrasound Gel in Resource-Limited Settings.","authors":"Sydney M Todorovich, Kristine Van Aarsen, Shane R Freeman, Adam Slomer, Frank Myslik","doi":"10.1177/10806032241259938","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>With point-of-care ultrasound (POCUS) use in austere environments comes the challenge of having an ever-available coupling medium for image generation. Commercial gel has numerous drawbacks that can limit its utility in these settings, and no studies have evaluated the potential for a reusable coupling medium. This study aimed to determine whether 3M™ Defib-Pads could be utilized as a reusable alternative to commercial gel for image generation in resource-limited settings.</p><p><strong>Methods: </strong>A descriptive, cross-sectional survey of Canadian physicians with POCUS interest was conducted to evaluate the interpretability of various POCUS images in a blinded fashion. Three anatomic regions (cardiac, abdominal, and nerve) were utilized, and image generation from the commercial gel and 7 Defib-Pad conditions were evaluated. These included pads that were 1) newly opened, 2) dirtied then rinsed, 3) air dried, 4) rinsed after being air dried, 5) frozen then thawed, 6) used in double thickness, and 7) used with a probe cover.</p><p><strong>Results: </strong>Compared to commercial gel, 3M™ Defib-Pads performed similarly, with adequate image interpretability of up to 100% in some conditions. The exception was pads that had prolonged air exposure, which produced images that were never interpretable. However, subsequent rinsing of these pads with water resulted in restored image generation.</p><p><strong>Conclusion: </strong>3M™ Defib-Pads were found to produce interpretable POCUS images under multiple environmental stressors and with different modalities of use, suggesting that 3M™ Defib-Pads can perform as a reusable gel alternative in resource-limited settings.</p>","PeriodicalId":49360,"journal":{"name":"Wilderness & Environmental Medicine","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Wilderness & Environmental Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/10806032241259938","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/18 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: With point-of-care ultrasound (POCUS) use in austere environments comes the challenge of having an ever-available coupling medium for image generation. Commercial gel has numerous drawbacks that can limit its utility in these settings, and no studies have evaluated the potential for a reusable coupling medium. This study aimed to determine whether 3M™ Defib-Pads could be utilized as a reusable alternative to commercial gel for image generation in resource-limited settings.
Methods: A descriptive, cross-sectional survey of Canadian physicians with POCUS interest was conducted to evaluate the interpretability of various POCUS images in a blinded fashion. Three anatomic regions (cardiac, abdominal, and nerve) were utilized, and image generation from the commercial gel and 7 Defib-Pad conditions were evaluated. These included pads that were 1) newly opened, 2) dirtied then rinsed, 3) air dried, 4) rinsed after being air dried, 5) frozen then thawed, 6) used in double thickness, and 7) used with a probe cover.
Results: Compared to commercial gel, 3M™ Defib-Pads performed similarly, with adequate image interpretability of up to 100% in some conditions. The exception was pads that had prolonged air exposure, which produced images that were never interpretable. However, subsequent rinsing of these pads with water resulted in restored image generation.
Conclusion: 3M™ Defib-Pads were found to produce interpretable POCUS images under multiple environmental stressors and with different modalities of use, suggesting that 3M™ Defib-Pads can perform as a reusable gel alternative in resource-limited settings.
期刊介绍:
Wilderness & Environmental Medicine, the official journal of the Wilderness Medical Society, is the leading journal for physicians practicing medicine in austere environments. This quarterly journal features articles on all aspects of wilderness medicine, including high altitude and climbing, cold- and heat-related phenomena, natural environmental disasters, immersion and near-drowning, diving, and barotrauma, hazardous plants/animals/insects/marine animals, animal attacks, search and rescue, ethical and legal issues, aeromedial transport, survival physiology, medicine in remote environments, travel medicine, operational medicine, and wilderness trauma management. It presents original research and clinical reports from scientists and practitioners around the globe. WEM invites submissions from authors who want to take advantage of our established publication''s unique scope, wide readership, and international recognition in the field of wilderness medicine. Its readership is a diverse group of medical and outdoor professionals who choose WEM as their primary wilderness medical resource.