The undetected murder? Evaluation and validation of a practicable and rapid inductively coupled plasma-mass spectrometry method for the detection of arsenic, lead, and thallium intoxications in postmortem blood.
Martin H J Wiesen, Dennis Schneider, Wolfgang Hein, Thomas Streichert, Martin Jübner, Hilke Andresen-Streichert
{"title":"The undetected murder? Evaluation and validation of a practicable and rapid inductively coupled plasma-mass spectrometry method for the detection of arsenic, lead, and thallium intoxications in postmortem blood.","authors":"Martin H J Wiesen, Dennis Schneider, Wolfgang Hein, Thomas Streichert, Martin Jübner, Hilke Andresen-Streichert","doi":"10.1002/dta.3749","DOIUrl":null,"url":null,"abstract":"<p><p>Homicide, suicide, or accident - elemental intoxication may be a cause in each of these types of deaths. Inductively coupled plasma mass spectrometry (ICP-MS) has emerged as the gold standard analytical method for toxic metal analysis in both clinical and forensic settings. An ICP-MS method was developed using a modified acidic workup for the quantitative determination of arsenic, lead, and thallium. Method validation focused on the assessment of linearity, between- and within-day precisions, limits of detection (LoD) and lower limits of quantification (LLoQ), and carryover. The method was applied to analysis of postmortem peripheral blood samples from 279 forensic cases for which orders for chemical-toxicological examination had been received from the public prosecutor's office. Using six-point and one-point calibrations (latter for rapid screening purposes), precisions and accuracies ranged from -4.8 to 5.8% and -6.4 to 7.5%. Analytical sensitivities for As, Pb, and Tl were 0.08, 0.18, and 0.01 μg/l (LoD) and 0.23, 0.66, and 0.03 μg/l (LLoQ), respectively. Observed postmortem peripheral blood concentrations were As, 1.31 ± 3.42 μg/L; Pb, 17.4 ± 13.1 μg/L; and Tl, 0.11 ± 0.07 μg/L (mean ± standard deviation [SD]). Elemental concentrations, determined in additional quality control samples, were in good agreement to those obtained with an external ICP-MS method based on alkaline sample processing. The current method is practicable and compatible with an ICP-MS system used for trace element analysis in an accredited medical laboratory. It allows for implementation of low-threshold investigations when metal intoxications are suspected in forensic routine.</p>","PeriodicalId":160,"journal":{"name":"Drug Testing and Analysis","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2024-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Drug Testing and Analysis","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/dta.3749","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
Homicide, suicide, or accident - elemental intoxication may be a cause in each of these types of deaths. Inductively coupled plasma mass spectrometry (ICP-MS) has emerged as the gold standard analytical method for toxic metal analysis in both clinical and forensic settings. An ICP-MS method was developed using a modified acidic workup for the quantitative determination of arsenic, lead, and thallium. Method validation focused on the assessment of linearity, between- and within-day precisions, limits of detection (LoD) and lower limits of quantification (LLoQ), and carryover. The method was applied to analysis of postmortem peripheral blood samples from 279 forensic cases for which orders for chemical-toxicological examination had been received from the public prosecutor's office. Using six-point and one-point calibrations (latter for rapid screening purposes), precisions and accuracies ranged from -4.8 to 5.8% and -6.4 to 7.5%. Analytical sensitivities for As, Pb, and Tl were 0.08, 0.18, and 0.01 μg/l (LoD) and 0.23, 0.66, and 0.03 μg/l (LLoQ), respectively. Observed postmortem peripheral blood concentrations were As, 1.31 ± 3.42 μg/L; Pb, 17.4 ± 13.1 μg/L; and Tl, 0.11 ± 0.07 μg/L (mean ± standard deviation [SD]). Elemental concentrations, determined in additional quality control samples, were in good agreement to those obtained with an external ICP-MS method based on alkaline sample processing. The current method is practicable and compatible with an ICP-MS system used for trace element analysis in an accredited medical laboratory. It allows for implementation of low-threshold investigations when metal intoxications are suspected in forensic routine.
期刊介绍:
As the incidence of drugs escalates in 21st century living, their detection and analysis have become increasingly important. Sport, the workplace, crime investigation, homeland security, the pharmaceutical industry and the environment are just some of the high profile arenas in which analytical testing has provided an important investigative tool for uncovering the presence of extraneous substances.
In addition to the usual publishing fare of primary research articles, case reports and letters, Drug Testing and Analysis offers a unique combination of; ‘How to’ material such as ‘Tutorials’ and ‘Reviews’, Speculative pieces (‘Commentaries’ and ‘Perspectives'', providing a broader scientific and social context to the aspects of analytical testing), ‘Annual banned substance reviews’ (delivering a critical evaluation of the methods used in the characterization of established and newly outlawed compounds).
Rather than focus on the application of a single technique, Drug Testing and Analysis employs a unique multidisciplinary approach to the field of controversial compound determination. Papers discussing chromatography, mass spectrometry, immunological approaches, 1D/2D gel electrophoresis, to name just a few select methods, are welcomed where their application is related to any of the six key topics listed below.