Applications of electrochemical impedance spectroscopy in disease diagnosis—A review

IF 6.5 Q1 BIOTECHNOLOGY & APPLIED MICROBIOLOGY
José A. Ribeiro , Pedro A.S. Jorge
{"title":"Applications of electrochemical impedance spectroscopy in disease diagnosis—A review","authors":"José A. Ribeiro ,&nbsp;Pedro A.S. Jorge","doi":"10.1016/j.snr.2024.100205","DOIUrl":null,"url":null,"abstract":"<div><p>Electrochemical impedance spectroscopy (EIS) is a reliable technique for gathering information about electrochemical process occurring at the electrode surface and investigating properties of materials. Furthermore, EIS technique can be a very versatile and valuable tool in analytical assays for detection and quantification of several chemically and biologically relevant (bio)molecules. The first part of this Review (<em>Introduction</em>) provides brief insights into (i) theoretical aspects of EIS, (ii) the instrumentation required to perform the EIS studies and (iii) the most relevant representations of impedance experimental data (such as Nyquist and Bode plots). In the end of this section, (iv) theoretical aspects regarding the fitting of the Randles circuit to experimental data are addressed, not only to obtain information about electrochemical processes but also to illustrate its utility for analytical purposes. The second part of the Review (<em>Impedimetric Detection of Disease Biomarkers</em>) focuses on the applications of EIS in the biomedical field, particularly as analytical technique in electrochemical sensors and biosensors for screening disease biomarkers. In the last section (<em>Conclusions and Perspectives</em>), we discuss main achievements of EIS technique in analytical assays and provide some perspectives, challenges and future applications in the biomedical field.</p></div>","PeriodicalId":426,"journal":{"name":"Sensors and Actuators Reports","volume":"8 ","pages":"Article 100205"},"PeriodicalIF":6.5000,"publicationDate":"2024-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666053924000213/pdfft?md5=f068273f787566f7142495848e036e2e&pid=1-s2.0-S2666053924000213-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors and Actuators Reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666053924000213","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Electrochemical impedance spectroscopy (EIS) is a reliable technique for gathering information about electrochemical process occurring at the electrode surface and investigating properties of materials. Furthermore, EIS technique can be a very versatile and valuable tool in analytical assays for detection and quantification of several chemically and biologically relevant (bio)molecules. The first part of this Review (Introduction) provides brief insights into (i) theoretical aspects of EIS, (ii) the instrumentation required to perform the EIS studies and (iii) the most relevant representations of impedance experimental data (such as Nyquist and Bode plots). In the end of this section, (iv) theoretical aspects regarding the fitting of the Randles circuit to experimental data are addressed, not only to obtain information about electrochemical processes but also to illustrate its utility for analytical purposes. The second part of the Review (Impedimetric Detection of Disease Biomarkers) focuses on the applications of EIS in the biomedical field, particularly as analytical technique in electrochemical sensors and biosensors for screening disease biomarkers. In the last section (Conclusions and Perspectives), we discuss main achievements of EIS technique in analytical assays and provide some perspectives, challenges and future applications in the biomedical field.

Abstract Image

疾病诊断中的电化学阻抗光谱应用 - 综述
电化学阻抗光谱(EIS)是收集电极表面电化学过程信息和研究材料特性的可靠技术。此外,电化学阻抗光谱技术还是一种非常通用和有价值的分析测试工具,可用于检测和量化多种化学和生物相关(生物)分子。本综述的第一部分(导言)简要介绍了:(i) EIS 的理论方面;(ii) 进行 EIS 研究所需的仪器;(iii) 阻抗实验数据的最相关表示方法(如奈奎斯特图和波特图)。在本节的最后,(iv) 讨论了有关兰德尔电路与实验数据拟合的理论问题,这不仅是为了获取有关电化学过程的信息,也是为了说明兰德尔电路在分析方面的实用性。综述的第二部分(疾病生物标志物的 Impedimetric Detection)侧重于 EIS 在生物医学领域的应用,特别是作为电化学传感器和生物传感器的分析技术,用于筛选疾病生物标志物。在最后一节(结论与展望)中,我们讨论了 EIS 技术在分析测试中的主要成就,并提出了生物医学领域的一些展望、挑战和未来应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
9.60
自引率
0.00%
发文量
60
审稿时长
49 days
期刊介绍: Sensors and Actuators Reports is a peer-reviewed open access journal launched out from the Sensors and Actuators journal family. Sensors and Actuators Reports is dedicated to publishing new and original works in the field of all type of sensors and actuators, including bio-, chemical-, physical-, and nano- sensors and actuators, which demonstrates significant progress beyond the current state of the art. The journal regularly publishes original research papers, reviews, and short communications. For research papers and short communications, the journal aims to publish the new and original work supported by experimental results and as such purely theoretical works are not accepted.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信