{"title":"The diagnostic performance of mean neutrophil volume in neonatal sepsis: A systematic review and meta-analysis","authors":"Alpana Mishra ,&nbsp;Pratap Kumar Jena ,&nbsp;Santosh Kumar Panda","doi":"10.1016/j.pedneo.2024.03.007","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>There is a need for reliable diagnostic tests for early identification of sepsis to prevent neonatal mortality and antibiotic misuse. During sepsis, many immature neutrophils came into the bloodstream, altering the mean neutrophil volume (MNV) shown in the previous studies.</div></div><div><h3>Objectives</h3><div>To summarize the diagnostic performance of mean neutrophil volume (MNV) in neonatal sepsis from the published literature.</div></div><div><h3>Method</h3><div>Databases such as PubMed, Scopus, and Web of Science were searched from January 1990 to April 2023 for studies reporting MNV as a diagnostic test in neonatal sepsis. The pooled sensitivity, specificity, diagnostic odds ratio (DOR), and area under the curve (AUC) of the summary receiver operating characteristic (SROC) curve of MNV were estimated with reference blood culture-positive sepsis and clinical sepsis for meta-analysis.</div></div><div><h3>Result</h3><div>The diagnostic performance of MNV was analyzed in 1685 neonates, including 829 septic and 856 non-septic neonates, from six prospective studies. The pooled sensitivity and specificity of MNV were 0.87 and 0.75, respectively, for neonatal sepsis; the DOR was 20.01 (95% CI: 5.90–67.82); and the AUC of the SROC for MNV was 0.81 (95% CI: 0.69–0.88). Higgins I<sup>2</sup> was 92.1% (95% CI: 85.5%–95.7%). The diagnostic performance of MNV was better during sub-group analysis of studies reporting culture-positive sepsis (DOR 85.61).</div></div><div><h3>Conclusion</h3><div>The diagnostic performance of MNV is moderate for neonatal sepsis. As the evidence originated from a small number of studies with marked heterogeneity, further large-scale diagnostic accuracy studies are recommended to resolve heterogeneity in the future.</div></div>","PeriodicalId":56095,"journal":{"name":"Pediatrics and Neonatology","volume":"66 1","pages":"Pages 71-75"},"PeriodicalIF":2.3000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pediatrics and Neonatology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1875957224000822","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PEDIATRICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background

There is a need for reliable diagnostic tests for early identification of sepsis to prevent neonatal mortality and antibiotic misuse. During sepsis, many immature neutrophils came into the bloodstream, altering the mean neutrophil volume (MNV) shown in the previous studies.

Objectives

To summarize the diagnostic performance of mean neutrophil volume (MNV) in neonatal sepsis from the published literature.

Method

Databases such as PubMed, Scopus, and Web of Science were searched from January 1990 to April 2023 for studies reporting MNV as a diagnostic test in neonatal sepsis. The pooled sensitivity, specificity, diagnostic odds ratio (DOR), and area under the curve (AUC) of the summary receiver operating characteristic (SROC) curve of MNV were estimated with reference blood culture-positive sepsis and clinical sepsis for meta-analysis.

Result

The diagnostic performance of MNV was analyzed in 1685 neonates, including 829 septic and 856 non-septic neonates, from six prospective studies. The pooled sensitivity and specificity of MNV were 0.87 and 0.75, respectively, for neonatal sepsis; the DOR was 20.01 (95% CI: 5.90–67.82); and the AUC of the SROC for MNV was 0.81 (95% CI: 0.69–0.88). Higgins I2 was 92.1% (95% CI: 85.5%–95.7%). The diagnostic performance of MNV was better during sub-group analysis of studies reporting culture-positive sepsis (DOR 85.61).

Conclusion

The diagnostic performance of MNV is moderate for neonatal sepsis. As the evidence originated from a small number of studies with marked heterogeneity, further large-scale diagnostic accuracy studies are recommended to resolve heterogeneity in the future.
新生儿败血症中平均中性粒细胞体积的诊断性能:系统回顾与元分析
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.10
自引率
0.00%
发文量
170
审稿时长
48 days
期刊介绍: Pediatrics and Neonatology is the official peer-reviewed publication of the Taiwan Pediatric Association and The Society of Neonatology ROC, and is indexed in EMBASE and SCOPUS. Articles on clinical and laboratory research in pediatrics and related fields are eligible for consideration.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信