Output Energy Regulation During RF Pulse in Proton Linac for Medicine

L. Ovchinnikova, A. Durkin, A. Kurilik, V. Paramonov
{"title":"Output Energy Regulation During RF Pulse in Proton Linac for Medicine","authors":"L. Ovchinnikova, A. Durkin, A. Kurilik, V. Paramonov","doi":"10.25205/2541-9447-2024-19-1-34-42","DOIUrl":null,"url":null,"abstract":"In proton therapy, depth scanning of the irradiated object is performed by changing the Output Energy (OE) of the accelerated beam. In pulsed linear accelerators, adjustment of the OE is usually by changing the amplitude and/or phase of the fi eld in the accelerating elements from one RF pulse to another. The application of non-inertial traveling wave accelerating sections makes it possible to change quickly the phase of the accelerating fi eld during the RF pulse. The phase of the fi eld in the constant gradient section is determined both by the phase of the input RF signal and by the process of wave propagation in the dispersive structure. The calculation results of the traveling wave propagation in the accelerating structure when the phase of the input RF signal changes and the results of simulation the dynamics of particles confirm the change in the linac’s OE during the RF pulse. The proposed method for regulation the OE makes it possible to increase in orders the speed of scanning the irradiated object by depth.","PeriodicalId":509351,"journal":{"name":"SIBERIAN JOURNAL OF PHYSICS","volume":"18 23","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SIBERIAN JOURNAL OF PHYSICS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25205/2541-9447-2024-19-1-34-42","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In proton therapy, depth scanning of the irradiated object is performed by changing the Output Energy (OE) of the accelerated beam. In pulsed linear accelerators, adjustment of the OE is usually by changing the amplitude and/or phase of the fi eld in the accelerating elements from one RF pulse to another. The application of non-inertial traveling wave accelerating sections makes it possible to change quickly the phase of the accelerating fi eld during the RF pulse. The phase of the fi eld in the constant gradient section is determined both by the phase of the input RF signal and by the process of wave propagation in the dispersive structure. The calculation results of the traveling wave propagation in the accelerating structure when the phase of the input RF signal changes and the results of simulation the dynamics of particles confirm the change in the linac’s OE during the RF pulse. The proposed method for regulation the OE makes it possible to increase in orders the speed of scanning the irradiated object by depth.
质子医用直子加速器射频脉冲期间的输出能量调节
在质子治疗中,通过改变加速束的输出能量(OE)来对照射物体进行深度扫描。在脉冲直线加速器中,通常通过改变加速元件中射频脉冲的振幅和/或相位来调整输出能量。非惯性行波加速部分的应用使得在射频脉冲期间快速改变加速元件的相位成为可能。恒定梯度部分的磁场相位由输入射频信号的相位和波在色散结构中的传播过程决定。输入射频信号相位变化时加速结构中行波传播的计算结果和粒子动力学模拟结果证实了射频脉冲期间直列加速器 OE 的变化。所提出的调节 OE 的方法使按深度扫描辐照对象的速度成级提高成为可能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书