Electrocochleography-Based Tonotopic Map: II. Frequency-to-Place Mismatch Impacts Speech-Perception Outcomes in Cochlear Implant Recipients.

IF 2.6 2区 医学 Q1 AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY
Ear and Hearing Pub Date : 2024-11-01 Epub Date: 2024-06-17 DOI:10.1097/AUD.0000000000001528
Amit Walia, Matthew A Shew, Jordan Varghese, Shannon M Lefler, Amrita Bhat, Amanda J Ortmann, Jacques A Herzog, Craig A Buchman
{"title":"Electrocochleography-Based Tonotopic Map: II. Frequency-to-Place Mismatch Impacts Speech-Perception Outcomes in Cochlear Implant Recipients.","authors":"Amit Walia, Matthew A Shew, Jordan Varghese, Shannon M Lefler, Amrita Bhat, Amanda J Ortmann, Jacques A Herzog, Craig A Buchman","doi":"10.1097/AUD.0000000000001528","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Modern cochlear implants (CIs) use varying-length electrode arrays inserted at varying insertion angles within variably sized cochleae. Thus, there exists an opportunity to enhance CI performance, particularly in postlinguistic adults, by optimizing the frequency-to-place allocation for electrical stimulation, thereby minimizing the need for central adaptation and plasticity. There has been interest in applying Greenwood or Stakhovskaya et al. function (describing the tonotopic map) to postoperative imaging of electrodes to improve frequency allocation and place coding. Acoustically-evoked electrocochleography (ECochG) allows for electrophysiologic best-frequency (BF) determination of CI electrodes and the potential for creating a personalized frequency allocation function. The objective of this study was to investigate the correlation between early speech-perception performance and frequency-to-place mismatch.</p><p><strong>Design: </strong>This retrospective study included 50 patients who received a slim perimodiolar electrode array. Following electrode insertion, five acoustic pure-tone stimuli ranging from 0.25 to 2 kHz were presented, and electrophysiological measurements were collected across all 22 electrode contacts. Cochlear microphonic tuning curves were subsequently generated for each stimulus frequency to ascertain the BF electrode or the location corresponding to the maximum response amplitude. Subsequently, we calculated the difference between the stimulus frequency and the patient's CI map's actual frequency allocation at each BF electrode, reflecting the frequency-to-place mismatch. BF electrocochleography-total response (BF-ECochG-TR), a measure of cochlear health, was also evaluated for each subject to control for the known impact of this measure on performance.</p><p><strong>Results: </strong>Our findings showed a moderate correlation ( r = 0.51; 95% confidence interval: 0.23 to 0.76) between the cumulative frequency-to-place mismatch, as determined using the ECochG-derived BF map (utilizing 500, 1000, and 2000 Hz), and 3-month performance on consonant-nucleus-consonant words (N = 38). Larger positive mismatches, shifted basal from the BF map, led to enhanced speech perception. Incorporating BF-ECochG-TR, total mismatch, and their interaction in a multivariate model explained 62% of the variance in consonant-nucleus-consonant word scores at 3 months. BF-ECochG-TR as a standalone predictor tended to overestimate performance for subjects with larger negative total mismatches and underestimated the performance for those with larger positive total mismatches. Neither cochlear diameter, number of cochlear turns, nor apical insertion angle accounted for the variability in total mismatch.</p><p><strong>Conclusions: </strong>Comparison of ECochG-BF derived tonotopic electrode maps to the frequency allocation tables reveals substantial mismatch, explaining 26.0% of the variability in CI performance in quiet. Closer examination of the mismatch shows that basally shifted maps at high frequencies demonstrate superior performance at 3 months compared with those with apically shifted maps (toward Greenwood and Stakhovskaya et al.). The implications of these results suggest that electrophysiological-based frequency reallocation might lead to enhanced speech-perception performance, especially when compared with conventional manufacturer maps or anatomic-based mapping strategies. Future research, exploring the prospective use of ECochG-based mapping techniques for frequency allocation is underway.</p>","PeriodicalId":55172,"journal":{"name":"Ear and Hearing","volume":null,"pages":null},"PeriodicalIF":2.6000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11493529/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ear and Hearing","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/AUD.0000000000001528","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/17 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: Modern cochlear implants (CIs) use varying-length electrode arrays inserted at varying insertion angles within variably sized cochleae. Thus, there exists an opportunity to enhance CI performance, particularly in postlinguistic adults, by optimizing the frequency-to-place allocation for electrical stimulation, thereby minimizing the need for central adaptation and plasticity. There has been interest in applying Greenwood or Stakhovskaya et al. function (describing the tonotopic map) to postoperative imaging of electrodes to improve frequency allocation and place coding. Acoustically-evoked electrocochleography (ECochG) allows for electrophysiologic best-frequency (BF) determination of CI electrodes and the potential for creating a personalized frequency allocation function. The objective of this study was to investigate the correlation between early speech-perception performance and frequency-to-place mismatch.

Design: This retrospective study included 50 patients who received a slim perimodiolar electrode array. Following electrode insertion, five acoustic pure-tone stimuli ranging from 0.25 to 2 kHz were presented, and electrophysiological measurements were collected across all 22 electrode contacts. Cochlear microphonic tuning curves were subsequently generated for each stimulus frequency to ascertain the BF electrode or the location corresponding to the maximum response amplitude. Subsequently, we calculated the difference between the stimulus frequency and the patient's CI map's actual frequency allocation at each BF electrode, reflecting the frequency-to-place mismatch. BF electrocochleography-total response (BF-ECochG-TR), a measure of cochlear health, was also evaluated for each subject to control for the known impact of this measure on performance.

Results: Our findings showed a moderate correlation ( r = 0.51; 95% confidence interval: 0.23 to 0.76) between the cumulative frequency-to-place mismatch, as determined using the ECochG-derived BF map (utilizing 500, 1000, and 2000 Hz), and 3-month performance on consonant-nucleus-consonant words (N = 38). Larger positive mismatches, shifted basal from the BF map, led to enhanced speech perception. Incorporating BF-ECochG-TR, total mismatch, and their interaction in a multivariate model explained 62% of the variance in consonant-nucleus-consonant word scores at 3 months. BF-ECochG-TR as a standalone predictor tended to overestimate performance for subjects with larger negative total mismatches and underestimated the performance for those with larger positive total mismatches. Neither cochlear diameter, number of cochlear turns, nor apical insertion angle accounted for the variability in total mismatch.

Conclusions: Comparison of ECochG-BF derived tonotopic electrode maps to the frequency allocation tables reveals substantial mismatch, explaining 26.0% of the variability in CI performance in quiet. Closer examination of the mismatch shows that basally shifted maps at high frequencies demonstrate superior performance at 3 months compared with those with apically shifted maps (toward Greenwood and Stakhovskaya et al.). The implications of these results suggest that electrophysiological-based frequency reallocation might lead to enhanced speech-perception performance, especially when compared with conventional manufacturer maps or anatomic-based mapping strategies. Future research, exploring the prospective use of ECochG-based mapping techniques for frequency allocation is underway.

基于电测听的声调图:II.频率-位置不匹配对人工耳蜗植入者言语感知结果的影响。
目的:现代人工耳蜗(CI)使用不同长度的电极阵列,以不同的插入角度插入不同大小的耳蜗。因此,有机会通过优化电刺激的频率-位置分配来提高人工耳蜗的性能,尤其是对语言后成人而言,从而最大限度地减少对中枢适应和可塑性的需求。将格林伍德或斯塔霍夫斯卡娅等人的功能(描述声调图谱)应用于术后电极成像,以改善频率分配和位置编码,一直备受关注。声诱发耳蜗电图(ECochG)可对 CI 电极进行电生理学最佳频率(BF)测定,并有可能创建个性化的频率分配功能。本研究旨在探讨早期语言感知能力与频率位置不匹配之间的相关性:这项回顾性研究包括 50 名接受纤细耳周电极阵列的患者。电极插入后,呈现 0.25 至 2 kHz 的五种纯音刺激,并收集所有 22 个电极触点的电生理测量结果。随后,我们生成了每个刺激频率的耳蜗微音调谐曲线,以确定BF电极或与最大响应振幅相对应的位置。随后,我们计算了刺激频率与患者 CI 地图在每个 BF 电极的实际频率分配之间的差值,以反映频率-位置不匹配。我们还对每个受试者的 BF 电测听总响应(BF-EcochG-TR)进行了评估,这是衡量耳蜗健康状况的一个指标,目的是控制该指标对听力表现的已知影响:我们的研究结果表明,使用 ECochG 导出的 BF 图(利用 500、1000 和 2000 Hz)确定的累积频率-位置错配与辅音-核-共鸣单词(N = 38)的 3 个月成绩之间存在中度相关性(r = 0.51;95% 置信区间:0.23 至 0.76)。较大的正向错配(从 BF 图转移到基底)可增强语音感知能力。将BF-ECochG-TR、总失配及其交互作用纳入多元模型,可解释3个月时辅音-核-共音词得分62%的差异。BF-ECochG-TR 作为一个独立的预测指标,往往会高估总失配负值较大的受试者的成绩,而低估总失配正值较大的受试者的成绩。耳蜗直径、耳蜗转数和耳尖插入角都不能解释总失配的变化:将 ECochG-BF 导出的音调电极图与频率分配表进行比较,发现了大量的不匹配,解释了安静时 CI 性能变异的 26.0%。对这种不匹配现象的进一步研究表明,与心尖偏移的图谱相比,高频率的基底偏移图谱在 3 个月后表现出更优越的性能(朝向 Greenwood 和 Stakhovskaya 等人)。这些结果的影响表明,基于电生理的频率重新分配可能会提高语言感知能力,尤其是与传统的制造商映射或基于解剖学的映射策略相比。目前正在进行未来研究,探索如何将基于心电图的映射技术用于频率分配。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Ear and Hearing
Ear and Hearing 医学-耳鼻喉科学
CiteScore
5.90
自引率
10.80%
发文量
207
审稿时长
6-12 weeks
期刊介绍: From the basic science of hearing and balance disorders to auditory electrophysiology to amplification and the psychological factors of hearing loss, Ear and Hearing covers all aspects of auditory and vestibular disorders. This multidisciplinary journal consolidates the various factors that contribute to identification, remediation, and audiologic and vestibular rehabilitation. It is the one journal that serves the diverse interest of all members of this professional community -- otologists, audiologists, educators, and to those involved in the design, manufacture, and distribution of amplification systems. The original articles published in the journal focus on assessment, diagnosis, and management of auditory and vestibular disorders.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信