A customised artificial neural network for power distribution system fault detection

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS
Arnav Bhagwat, Soham Dutta, Vinay Kumar Jadoun, Arigela Satya Veerendra, Sourav Kumar Sahu
{"title":"A customised artificial neural network for power distribution system fault detection","authors":"Arnav Bhagwat,&nbsp;Soham Dutta,&nbsp;Vinay Kumar Jadoun,&nbsp;Arigela Satya Veerendra,&nbsp;Sourav Kumar Sahu","doi":"10.1049/gtd2.13186","DOIUrl":null,"url":null,"abstract":"<p>Machine learned fault detection approaches are being increasingly used for fault detection in distribution grid. However, the performance of the models can be improved by customizing the models. In this regard, a customised artificial neural network (CANN) for fault detection in a distribution grid is proposed in this paper. The proposed work develops a CANN that combines the “up-pyramid” and “down-pyramid” model of ANN into a “custom-pyramid” model. As a result, the same model can be used both for determining the types of fault as well as its location. The data needed to train the model has been taken from a reconfigured IEEE-33 bus distribution system developed in Typhoon HIL real-time simulator. Spectral-kurtosis is utilized for extraction of features of the faulted transient signals which are used as input data to develop the CANN. The result showcases that the reduction of input features reduces computational complexity without compromising its accuracy. The proposed model classifies fault location with an accuracy of 95.43%. The proposed method also identifies fault type with an accuracy of 96.08%. Several test cases have been developed to test the method. The method proved to be able to perform in most of the cases.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/gtd2.13186","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/gtd2.13186","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

Abstract

Machine learned fault detection approaches are being increasingly used for fault detection in distribution grid. However, the performance of the models can be improved by customizing the models. In this regard, a customised artificial neural network (CANN) for fault detection in a distribution grid is proposed in this paper. The proposed work develops a CANN that combines the “up-pyramid” and “down-pyramid” model of ANN into a “custom-pyramid” model. As a result, the same model can be used both for determining the types of fault as well as its location. The data needed to train the model has been taken from a reconfigured IEEE-33 bus distribution system developed in Typhoon HIL real-time simulator. Spectral-kurtosis is utilized for extraction of features of the faulted transient signals which are used as input data to develop the CANN. The result showcases that the reduction of input features reduces computational complexity without compromising its accuracy. The proposed model classifies fault location with an accuracy of 95.43%. The proposed method also identifies fault type with an accuracy of 96.08%. Several test cases have been developed to test the method. The method proved to be able to perform in most of the cases.

Abstract Image

用于配电系统故障检测的定制人工神经网络
机器学习故障检测方法正越来越多地用于配电网故障检测。然而,通过定制模型可以提高模型的性能。为此,本文提出了一种用于配电网故障检测的定制人工神经网络 (CANN)。所提出的工作开发了一种 CANN,它将人工神经网络的 "上金字塔 "和 "下金字塔 "模型结合成一个 "定制金字塔 "模型。因此,同一模型既可用于确定故障类型,也可用于确定故障位置。训练模型所需的数据取自在 Typhoon HIL 实时模拟器中开发的重新配置的 IEEE-33 总线配电系统。利用频谱峰度提取故障瞬态信号的特征,并将其作为开发 CANN 的输入数据。结果表明,输入特征的减少降低了计算复杂度,但并不影响其准确性。所提出的模型对故障位置的分类准确率高达 95.43%。所提出的方法还能识别故障类型,准确率高达 96.08%。为测试该方法,开发了多个测试案例。事实证明,该方法在大多数情况下都能发挥作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信