A simple assay for cyclic adenosine 3':5'-monophosphate in human saliva.

U Glenert, A Geisler
{"title":"A simple assay for cyclic adenosine 3':5'-monophosphate in human saliva.","authors":"U Glenert,&nbsp;A Geisler","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Methods specially designed for the assay of cyclic adenosine 3':5'-monophosphate (cAMP) in human saliva have not previously been published. Methods for measurements in plasma or tissue preparations are inapplicable to saliva due to interference. This interference can be reduced by calibrating standard solutions with reagent blanks prepared from saliva pre-treated to remove cAMP (by charcoal adsorption). Further, human saliva contains only small amounts of cAMP (approximately 0.2 pmol/50 microliters saliva). The method presented provides the necessary sensitivity (lower detection limit: 0.02 pmol/50 microliters) obtained by adjustments of tracer and binding protein concentrations. The method is simple and has a comparatively great capacity for the number of test tubes to be assayed.</p>","PeriodicalId":15406,"journal":{"name":"Journal of cyclic nucleotide and protein phosphorylation research","volume":"10 5","pages":"451-61"},"PeriodicalIF":0.0000,"publicationDate":"1985-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cyclic nucleotide and protein phosphorylation research","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Methods specially designed for the assay of cyclic adenosine 3':5'-monophosphate (cAMP) in human saliva have not previously been published. Methods for measurements in plasma or tissue preparations are inapplicable to saliva due to interference. This interference can be reduced by calibrating standard solutions with reagent blanks prepared from saliva pre-treated to remove cAMP (by charcoal adsorption). Further, human saliva contains only small amounts of cAMP (approximately 0.2 pmol/50 microliters saliva). The method presented provides the necessary sensitivity (lower detection limit: 0.02 pmol/50 microliters) obtained by adjustments of tracer and binding protein concentrations. The method is simple and has a comparatively great capacity for the number of test tubes to be assayed.

人唾液中环腺苷3′:5′-单磷酸的简单测定。
专门设计用于测定人唾液中环腺苷3′:5′-单磷酸(cAMP)的方法以前尚未发表。由于干扰,血浆或组织制剂中的测量方法不适用于唾液。这种干扰可以通过用预处理的唾液制备的试剂空白来校准标准溶液来减少(通过木炭吸附)。此外,人类唾液只含有少量cAMP(大约0.2 pmol/50微升唾液)。该方法通过调整示踪剂和结合蛋白的浓度,提供了必要的灵敏度(最低检测限:0.02 pmol/50微升)。该方法简单,并且对于要分析的试管数量具有相对较大的容量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信