A clinical-radiomics nomogram based on automated segmentation of chest CT to discriminate PRISm and COPD patients

IF 1.8 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
TaoHu Zhou , Yu Guan , XiaoQing Lin , XiuXiu Zhou , Liang Mao , YanQing Ma , Bing Fan , Jie Li , WenTing Tu , ShiYuan Liu , Li Fan
{"title":"A clinical-radiomics nomogram based on automated segmentation of chest CT to discriminate PRISm and COPD patients","authors":"TaoHu Zhou ,&nbsp;Yu Guan ,&nbsp;XiaoQing Lin ,&nbsp;XiuXiu Zhou ,&nbsp;Liang Mao ,&nbsp;YanQing Ma ,&nbsp;Bing Fan ,&nbsp;Jie Li ,&nbsp;WenTing Tu ,&nbsp;ShiYuan Liu ,&nbsp;Li Fan","doi":"10.1016/j.ejro.2024.100580","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><p>It is vital to develop noninvasive approaches with high accuracy to discriminate the preserved ratio impaired spirometry (PRISm) group from the chronic obstructive pulmonary disease (COPD) groups. Radiomics has emerged as an image analysis technique. This study aims to develop and confirm the new radiomics-based noninvasive approach to discriminate these two groups.</p></div><div><h3>Methods</h3><p>Totally 1066 subjects from 4 centers were included in this retrospective research, and classified into training, internal validation or external validation sets. The chest computed tomography (CT) images were segmented by the fully automated deep learning segmentation algorithm (Unet231) for radiomics feature extraction. We established the radiomics signature (Rad-score) using the least absolute shrinkage and selection operator algorithm, then conducted ten-fold cross-validation using the training set. Last, we constructed a radiomics signature by incorporating independent risk factors using the multivariate logistic regression model. Model performance was evaluated by receiver operating characteristic (ROC) curve, calibration curve, and decision curve analyses (DCA).</p></div><div><h3>Results</h3><p>The Rad-score, including 15 radiomic features in whole-lung region, which was suitable for diffuse lung diseases, was demonstrated to be effective for discriminating between PRISm and COPD. Its diagnostic accuracy was improved through integrating Rad-score with a clinical model, and the area under the ROC (AUC) were 0.82(95 %CI 0.79–0.86), 0.77(95 %CI 0.72–0.83) and 0.841(95 %CI 0.78–0.91) for training, internal validation and external validation sets, respectively. As revealed by analysis, radiomics nomogram showed good fit and superior clinical utility.</p></div><div><h3>Conclusions</h3><p>The present work constructed the new radiomics-based nomogram and verified its reliability for discriminating between PRISm and COPD.</p></div>","PeriodicalId":38076,"journal":{"name":"European Journal of Radiology Open","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2024-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2352047724000352/pdfft?md5=4350c77666fa3e691e8c4b13e144787a&pid=1-s2.0-S2352047724000352-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Radiology Open","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352047724000352","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

It is vital to develop noninvasive approaches with high accuracy to discriminate the preserved ratio impaired spirometry (PRISm) group from the chronic obstructive pulmonary disease (COPD) groups. Radiomics has emerged as an image analysis technique. This study aims to develop and confirm the new radiomics-based noninvasive approach to discriminate these two groups.

Methods

Totally 1066 subjects from 4 centers were included in this retrospective research, and classified into training, internal validation or external validation sets. The chest computed tomography (CT) images were segmented by the fully automated deep learning segmentation algorithm (Unet231) for radiomics feature extraction. We established the radiomics signature (Rad-score) using the least absolute shrinkage and selection operator algorithm, then conducted ten-fold cross-validation using the training set. Last, we constructed a radiomics signature by incorporating independent risk factors using the multivariate logistic regression model. Model performance was evaluated by receiver operating characteristic (ROC) curve, calibration curve, and decision curve analyses (DCA).

Results

The Rad-score, including 15 radiomic features in whole-lung region, which was suitable for diffuse lung diseases, was demonstrated to be effective for discriminating between PRISm and COPD. Its diagnostic accuracy was improved through integrating Rad-score with a clinical model, and the area under the ROC (AUC) were 0.82(95 %CI 0.79–0.86), 0.77(95 %CI 0.72–0.83) and 0.841(95 %CI 0.78–0.91) for training, internal validation and external validation sets, respectively. As revealed by analysis, radiomics nomogram showed good fit and superior clinical utility.

Conclusions

The present work constructed the new radiomics-based nomogram and verified its reliability for discriminating between PRISm and COPD.

基于胸部 CT 自动分割的临床放射组学提名图,用于区分 PRISm 和 COPD 患者
目的:开发高准确度的无创方法,从慢性阻塞性肺病(COPD)组中区分肺活量比值受损组(PRISm)至关重要。放射组学已成为一种图像分析技术。本研究旨在开发和证实基于放射组学的新的无创方法,以区分这两组患者。方法本回顾性研究共纳入了来自 4 个中心的 1066 名受试者,并将其分为训练集、内部验证集或外部验证集。采用全自动深度学习分割算法(Unet231)对胸部计算机断层扫描(CT)图像进行分割,以提取放射组学特征。我们使用最小绝对收缩和选择算子算法建立了放射组学特征(Rad-score),然后使用训练集进行了十倍交叉验证。最后,我们利用多元逻辑回归模型,结合独立的风险因素,构建了放射组学特征。通过接收器操作特征曲线(ROC)、校准曲线和决策曲线分析(DCA)对模型的性能进行了评估。结果Rad-score包括全肺区域的15个放射组学特征,适用于弥漫性肺部疾病,被证明能有效区分PRISm和COPD。在训练集、内部验证集和外部验证集上,ROC 下面积(AUC)分别为 0.82(95 %CI 0.79-0.86)、0.77(95 %CI 0.72-0.83)和 0.841(95 %CI 0.78-0.91)。结论 本研究构建了新的基于放射组学的提名图,并验证了其区分 PRISm 和 COPD 的可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
European Journal of Radiology Open
European Journal of Radiology Open Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
4.10
自引率
5.00%
发文量
55
审稿时长
51 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信