Ventilation practices in the neonatal intensive care units in Saudi Arabia, survey of the utilization of volume-targeted ventilation among practicing neonatologists.

Q2 Medicine
M Al Qurashi, A Al Qahtani, M Al Hindi, A Mustafa, A Ahmed, S S Aga, A Al Khotani, H Kandil, J Alallah, A Sallam
{"title":"Ventilation practices in the neonatal intensive care units in Saudi Arabia, survey of the utilization of volume-targeted ventilation among practicing neonatologists.","authors":"M Al Qurashi, A Al Qahtani, M Al Hindi, A Mustafa, A Ahmed, S S Aga, A Al Khotani, H Kandil, J Alallah, A Sallam","doi":"10.3233/NPM-240054","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To assess the current practice in using volume-targeted ventilation among neonatologists working at the Neonatal Intensive Care Units (NICU) of Saudi Arabia.</p><p><strong>Methods: </strong>The questionnaire was provided electronically to 153 practicing Neonatologists working in 39 NICUs. The survey's results were received and statistically analyzed.</p><p><strong>Results: </strong>One hundred nineteen (119) responses were received with, a 78% response rate. Volume Targeted Ventilation (VTV) was used routinely by 67.2%, whereas 21.8% still use only pressure control (PC)/pressure limited (PL) mode. During the acute phase of ventilation support, Assist Control was the most popular synchronized mode, whereas Synchronized Intermittent Mandatory Ventilation (SIMV) with pressure support (PS) or PSV were the two most common modes during the weaning phase, 31.8%, and 31% respectively. The majority of the neonatologists used a tidal volume of 4 ml/kg as the lowest and 6 ml/kg as the highest. The major reasons for not implementing VTV were the limited availability of ventilator devices that have an option of VTV, followed by lack of experience.</p><p><strong>Conclusion: </strong>VTV is the predominant ventilation practice approach among neonatologists working in the KSA. Limited availability and lack of experience in using are the main challenges. Efforts to equip NICUs with the most advanced ventilation technology, enhance practitioners' experience and sufficient training in its use are warranted.</p>","PeriodicalId":16537,"journal":{"name":"Journal of neonatal-perinatal medicine","volume":" ","pages":"653-660"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of neonatal-perinatal medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3233/NPM-240054","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To assess the current practice in using volume-targeted ventilation among neonatologists working at the Neonatal Intensive Care Units (NICU) of Saudi Arabia.

Methods: The questionnaire was provided electronically to 153 practicing Neonatologists working in 39 NICUs. The survey's results were received and statistically analyzed.

Results: One hundred nineteen (119) responses were received with, a 78% response rate. Volume Targeted Ventilation (VTV) was used routinely by 67.2%, whereas 21.8% still use only pressure control (PC)/pressure limited (PL) mode. During the acute phase of ventilation support, Assist Control was the most popular synchronized mode, whereas Synchronized Intermittent Mandatory Ventilation (SIMV) with pressure support (PS) or PSV were the two most common modes during the weaning phase, 31.8%, and 31% respectively. The majority of the neonatologists used a tidal volume of 4 ml/kg as the lowest and 6 ml/kg as the highest. The major reasons for not implementing VTV were the limited availability of ventilator devices that have an option of VTV, followed by lack of experience.

Conclusion: VTV is the predominant ventilation practice approach among neonatologists working in the KSA. Limited availability and lack of experience in using are the main challenges. Efforts to equip NICUs with the most advanced ventilation technology, enhance practitioners' experience and sufficient training in its use are warranted.

沙特阿拉伯新生儿重症监护室的通气实践,对执业新生儿科医生使用容量目标通气的调查。
目的评估在沙特阿拉伯新生儿重症监护病房(NICU)工作的新生儿科医生目前使用容量目标通气的情况:通过电子方式向在 39 个新生儿重症监护室工作的 153 名执业新生儿科医生发放了调查问卷。结果:共收到 119 份调查问卷:结果:共收到 119 份回复,回复率为 78%。67.2%的患者常规使用容量目标通气(VTV),21.8%的患者仍然只使用压力控制(PC)/压力限制(PL)模式。在通气支持的急性期,辅助控制是最常用的同步模式,而带压力支持(PS)的同步间歇强制通气(SIMV)或 PSV 是断奶期最常用的两种模式,分别占 31.8% 和 31%。大多数新生儿科医生使用的潮气量最低为 4 毫升/千克,最高为 6 毫升/千克。未实施 VTV 的主要原因是可选择 VTV 的呼吸机设备有限,其次是缺乏经验:结论:在 KSA 工作的新生儿科医生中,VTV 是最主要的通气方法。供应有限和缺乏使用经验是主要挑战。有必要努力为新生儿重症监护室配备最先进的通气技术,提高从业人员的经验,并对其使用进行充分培训。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of neonatal-perinatal medicine
Journal of neonatal-perinatal medicine Medicine-Pediatrics, Perinatology and Child Health
CiteScore
2.00
自引率
0.00%
发文量
124
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信