Bacterial adhesion and surface properties of computer-aided design-computer-aided manufacturing restorative materials.

IF 1.9 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Journal of oral science Pub Date : 2024-07-16 Epub Date: 2024-06-12 DOI:10.2334/josnusd.24-0056
Çağatay Barutçugil, Deniz Tayfun, Nurgül Çetin Tuncer, Ayşe Dündar
{"title":"Bacterial adhesion and surface properties of computer-aided design-computer-aided manufacturing restorative materials.","authors":"Çağatay Barutçugil, Deniz Tayfun, Nurgül Çetin Tuncer, Ayşe Dündar","doi":"10.2334/josnusd.24-0056","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to evaluate the surface properties and bacterial adhesion of computer-aided design-computer-aided manufacturing (CAD-CAM) restorative materials.</p><p><strong>Methods: </strong>Four CAD-CAM resin-based blocks (Vita Enamic, Shofu block HC, Cerasmart [CS] and Lava Ultimate [LU]) and a leucite-reinforced glass ceramic block (IPS Empress CAD) were used in the present study. Specimens prepared with dimensions of 10 × 10 × 1 mm were polished. Surface characteristics were assessed with hydrophobicity and surface free energy (SFE) analysis. Surface roughness was measured using a profilometer, and elemental and topographic evaluations were performed with SEM-EDX analysis. After being kept in artificial saliva for 1 h, Streptococcus mutans (S. mutans) and Streptococcus mitis (S. mitis) were incubated separately in 5% CO<sub>2</sub> atmosphere at 37°C for 24 h. The adhered bacteria were counted as ×10<sup>8</sup> CFU/mL.</p><p><strong>Results: </strong>Surface roughness, contact angle and SFE measurement values were found to be in the range of 0.144-0.264 Ra, 28.362°-70.074° and 39.65-63.62 mN/m, respectively. The highest adhered amount of S. mutans was found in CS and the lowest in LU, while there was no significant difference between the amounts of adhered S. mitis.</p><p><strong>Conclusion: </strong>Despite differences in the surface properties of the materials used for the study, the materials exhibited identical properties with respect to bacterial adhesion.</p>","PeriodicalId":16646,"journal":{"name":"Journal of oral science","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2024-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of oral science","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.2334/josnusd.24-0056","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/12 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study aimed to evaluate the surface properties and bacterial adhesion of computer-aided design-computer-aided manufacturing (CAD-CAM) restorative materials.

Methods: Four CAD-CAM resin-based blocks (Vita Enamic, Shofu block HC, Cerasmart [CS] and Lava Ultimate [LU]) and a leucite-reinforced glass ceramic block (IPS Empress CAD) were used in the present study. Specimens prepared with dimensions of 10 × 10 × 1 mm were polished. Surface characteristics were assessed with hydrophobicity and surface free energy (SFE) analysis. Surface roughness was measured using a profilometer, and elemental and topographic evaluations were performed with SEM-EDX analysis. After being kept in artificial saliva for 1 h, Streptococcus mutans (S. mutans) and Streptococcus mitis (S. mitis) were incubated separately in 5% CO2 atmosphere at 37°C for 24 h. The adhered bacteria were counted as ×108 CFU/mL.

Results: Surface roughness, contact angle and SFE measurement values were found to be in the range of 0.144-0.264 Ra, 28.362°-70.074° and 39.65-63.62 mN/m, respectively. The highest adhered amount of S. mutans was found in CS and the lowest in LU, while there was no significant difference between the amounts of adhered S. mitis.

Conclusion: Despite differences in the surface properties of the materials used for the study, the materials exhibited identical properties with respect to bacterial adhesion.

计算机辅助设计-计算机辅助制造修复材料的细菌附着力和表面特性。
目的:本研究旨在评估计算机辅助设计-计算机辅助制造(CAD-CAM)修复材料的表面特性和细菌附着力:本研究使用了四种 CAD-CAM 树脂基块(Vita Enamic、Shofu block HC、Cerasmart [CS] 和 Lava Ultimate [LU])和一种白榴石强化玻璃陶瓷基块(IPS Empress CAD)。制备的试样尺寸为 10 × 10 × 1 毫米,并进行了抛光。通过疏水性和表面自由能(SFE)分析评估了表面特征。使用轮廓仪测量表面粗糙度,并通过 SEM-EDX 分析进行元素和形貌评估。在人工唾液中保持 1 小时后,将变异链球菌(S. mutans)和米氏链球菌(S. mitis)分别在 5%的二氧化碳环境中于 37°C 培养 24 小时:结果:表面粗糙度、接触角和 SFE 测量值的范围分别为 0.144-0.264 Ra、28.362°-70.074° 和 39.65-63.62 mN/m。在 CS 中发现的变异单胞菌的附着量最高,而在 LU 中发现的变异单胞菌的附着量最低,而变异单胞菌的附着量之间没有显著差异:结论:尽管研究所用材料的表面特性不同,但这些材料在细菌粘附方面表现出相同的特性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of oral science
Journal of oral science DENTISTRY, ORAL SURGERY & MEDICINE-MATERIALS SCIENCE, BIOMATERIALS
CiteScore
3.80
自引率
0.00%
发文量
58
期刊介绍: Information not localized
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信