Intrahepatic Gas Caused by Acute Gastroenteritis: Hepatic Portal Venous Gas or Biliary Tract Gas?

IF 0.7 Q3 MEDICINE, GENERAL & INTERNAL
International Medical Case Reports Journal Pub Date : 2024-06-07 eCollection Date: 2024-01-01 DOI:10.2147/IMCRJ.S468694
Chunhua Wang, Haifeng Jin, Hua Xue, Yanwei Zhang
{"title":"Intrahepatic Gas Caused by Acute Gastroenteritis: Hepatic Portal Venous Gas or Biliary Tract Gas?","authors":"Chunhua Wang, Haifeng Jin, Hua Xue, Yanwei Zhang","doi":"10.2147/IMCRJ.S468694","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Hepatic portal venous gas is not a specific disease and is often only an imaging manifestation in patients with acute abdomen. However, its appearance often indicates serious disease and poor prognosis. It is not difficult to distinguish typical portal venous gas from biliary tract gas on computed tomography because of their relatively different distribution within the liver. But the difference is not absolute.</p><p><strong>Case description: </strong>An 82-year-old female was admitted to the emergency department due to epigastric pain, nausea and vomiting for 1 day. Intrahepatic gas was found on computed tomography (CT), which was initially diagnosed as portal venous gas, and contrast-enhanced abdominal CT was performed 3 hours after the first plain CT scan and revealed a significant reduction of intrahepatic gas, then diagnosed as biliary tract gas. Two days later, enhanced abdominal CT showed that biliary tract gas had disappeared. Continuous gastrointestinal decompression, anti-infection, rehydration and other treatments were given. After treatment, abdominal pain, nausea, vomiting and other symptoms of the patient were gradually relieved. The patient refused gastroenteroscopy and was discharged after 13 days of hospitalization.</p><p><strong>Conclusion: </strong>Portal venous gas and biliary tract gas may have similar CT findings and be misdiagnosed, and enhanced CT examination is necessary to confirm the diagnosis.</p>","PeriodicalId":14337,"journal":{"name":"International Medical Case Reports Journal","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2024-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11166165/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Medical Case Reports Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/IMCRJ.S468694","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Hepatic portal venous gas is not a specific disease and is often only an imaging manifestation in patients with acute abdomen. However, its appearance often indicates serious disease and poor prognosis. It is not difficult to distinguish typical portal venous gas from biliary tract gas on computed tomography because of their relatively different distribution within the liver. But the difference is not absolute.

Case description: An 82-year-old female was admitted to the emergency department due to epigastric pain, nausea and vomiting for 1 day. Intrahepatic gas was found on computed tomography (CT), which was initially diagnosed as portal venous gas, and contrast-enhanced abdominal CT was performed 3 hours after the first plain CT scan and revealed a significant reduction of intrahepatic gas, then diagnosed as biliary tract gas. Two days later, enhanced abdominal CT showed that biliary tract gas had disappeared. Continuous gastrointestinal decompression, anti-infection, rehydration and other treatments were given. After treatment, abdominal pain, nausea, vomiting and other symptoms of the patient were gradually relieved. The patient refused gastroenteroscopy and was discharged after 13 days of hospitalization.

Conclusion: Portal venous gas and biliary tract gas may have similar CT findings and be misdiagnosed, and enhanced CT examination is necessary to confirm the diagnosis.

急性肠胃炎引起的肝内积气:肝门静脉积气还是胆道积气?
目的:肝门静脉积气不是一种特异性疾病,通常只是急腹症患者的一种影像学表现。然而,它的出现往往预示着严重的疾病和不良的预后。由于典型的门静脉积气和胆道积气在肝脏内的分布相对不同,因此在计算机断层扫描上不难区分。但这种区别并不是绝对的:一位 82 岁的女性因上腹疼痛、恶心和呕吐 1 天而被送入急诊科。计算机断层扫描(CT)发现肝内气体,初步诊断为门静脉积气,在第一次CT平扫3小时后进行了对比增强腹部CT,发现肝内气体明显减少,随后诊断为胆道积气。两天后,增强腹部 CT 显示胆道气体已消失。给予持续胃肠减压、抗感染、补液等治疗。治疗后,患者的腹痛、恶心、呕吐等症状逐渐缓解。患者拒绝胃肠镜检查,住院 13 天后出院:结论:门静脉积气和胆道积气可能有相似的 CT 检查结果而被误诊,需要加强 CT 检查以确诊。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
International Medical Case Reports Journal
International Medical Case Reports Journal MEDICINE, GENERAL & INTERNAL-
CiteScore
1.40
自引率
0.00%
发文量
135
审稿时长
16 weeks
期刊介绍: International Medical Case Reports Journal is an international, peer-reviewed, open access, online journal publishing original case reports from all medical specialties. Submissions should not normally exceed 3,000 words or 4 published pages including figures, diagrams and references. As of 1st April 2019, the International Medical Case Reports Journal will no longer consider meta-analyses for publication.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信