{"title":"Assessing ultrasound probe stabilization for quantifying speech production contrasts using the Adjustable Laboratory Probe Holder for UltraSound (ALPHUS)","authors":"Wei-Rong Chen ,&nbsp;Michael C. Stern ,&nbsp;D.H. Whalen ,&nbsp;Donald Derrick ,&nbsp;Christopher Carignan ,&nbsp;Catherine T. Best ,&nbsp;Mark Tiede","doi":"10.1016/j.wocn.2024.101339","DOIUrl":null,"url":null,"abstract":"<div><p>Ultrasound imaging of the tongue is biased by the probe movements relative to the speaker’s head. Two common remedies are restricting or algorithmically compensating for such movements, each with its own challenges. We describe these challenges in details and evaluate an open-source, adjustable probe stabilizer for ultrasound (ALPHUS), specifically designed to address these challenges by restricting uncorrectable probe movements while allowing for correctable ones (e.g., jaw opening) to facilitate naturalness. The stabilizer is highly modular and adaptable to different users (e.g., adults and children) and different research/clinical needs (e.g., imaging in both midsagittal and coronal orientations). The results of three experiments show that probe movement over uncorrectable degrees of freedom was negligible, while movement over correctable degrees of freedom that could be compensated through post-processing alignment was relatively large, indicating unconstrained articulation over parameters relevant for natural speech. Results also showed that probe movements as small as 5 mm or 2 degrees can neutralize phonemic contrasts in ultrasound tongue positions. This demonstrates that while stabilized but uncorrected ultrasound imaging can provide reliable tongue shape information (e.g., curvature or complexity), accurate tongue position (e.g., height or backness) with respect to vocal tract hard structure needs correction for probe displacement relative to the head.</p></div>","PeriodicalId":51397,"journal":{"name":"Journal of Phonetics","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2024-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Phonetics","FirstCategoryId":"98","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0095447024000457","RegionNum":1,"RegionCategory":"文学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"0","JCRName":"LANGUAGE & LINGUISTICS","Score":null,"Total":0}
引用次数: 0

Abstract

Ultrasound imaging of the tongue is biased by the probe movements relative to the speaker’s head. Two common remedies are restricting or algorithmically compensating for such movements, each with its own challenges. We describe these challenges in details and evaluate an open-source, adjustable probe stabilizer for ultrasound (ALPHUS), specifically designed to address these challenges by restricting uncorrectable probe movements while allowing for correctable ones (e.g., jaw opening) to facilitate naturalness. The stabilizer is highly modular and adaptable to different users (e.g., adults and children) and different research/clinical needs (e.g., imaging in both midsagittal and coronal orientations). The results of three experiments show that probe movement over uncorrectable degrees of freedom was negligible, while movement over correctable degrees of freedom that could be compensated through post-processing alignment was relatively large, indicating unconstrained articulation over parameters relevant for natural speech. Results also showed that probe movements as small as 5 mm or 2 degrees can neutralize phonemic contrasts in ultrasound tongue positions. This demonstrates that while stabilized but uncorrected ultrasound imaging can provide reliable tongue shape information (e.g., curvature or complexity), accurate tongue position (e.g., height or backness) with respect to vocal tract hard structure needs correction for probe displacement relative to the head.

使用可调式超声波实验室探头架 (ALPHUS) 评估超声波探头的稳定性,以量化语音生成对比度
舌头的超声波成像会因探头相对于说话者头部的移动而产生偏差。两种常见的补救方法是限制或通过算法补偿这种运动,但每种方法都有其自身的挑战。我们详细描述了这些挑战,并评估了一种开源、可调节的超声探头稳定器(ALPHUS),该稳定器专为解决这些挑战而设计,可限制不可修正的探头运动,同时允许可修正的运动(如下颌张开),以促进自然度。该稳定器高度模块化,可适应不同用户(如成人和儿童)和不同的研究/临床需求(如中矢状和冠状两个方向的成像)。三项实验的结果表明,探头在不可校正自由度上的移动可以忽略不计,而在可校正自由度上的移动(可通过后处理对齐进行补偿)则相对较大,这表明在与自然语音相关的参数上的衔接不受限制。结果还显示,小到 5 毫米或 2 度的探头移动都能中和超声波舌位的音位对比。这表明,虽然稳定但未经校正的超声波成像可提供可靠的舌形信息(如弧度或复杂度),但相对于声道硬结构的准确舌位(如高度或后度)需要校正探头相对于头部的位移。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.50
自引率
26.30%
发文量
49
期刊介绍: The Journal of Phonetics publishes papers of an experimental or theoretical nature that deal with phonetic aspects of language and linguistic communication processes. Papers dealing with technological and/or pathological topics, or papers of an interdisciplinary nature are also suitable, provided that linguistic-phonetic principles underlie the work reported. Regular articles, review articles, and letters to the editor are published. Themed issues are also published, devoted entirely to a specific subject of interest within the field of phonetics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信