Chankue Park, Arash Azhideh, Atefe Pooyan, Ehsan Alipour, Sara Haseli, Ishan Satwah, Majid Chalian
{"title":"Diagnostic performance and inter-reader reliability of bone reporting and data system (Bone-RADS) on computed tomography.","authors":"Chankue Park, Arash Azhideh, Atefe Pooyan, Ehsan Alipour, Sara Haseli, Ishan Satwah, Majid Chalian","doi":"10.1007/s00256-024-04721-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the diagnostic performance and inter-reader reliability of the Bone Reporting and Data System (Bone-RADS) for solitary bone lesions on CT.</p><p><strong>Materials and methods: </strong>This retrospective analysis included 179 patients (mean age, 56 ± 18 years; 94 men) who underwent bone biopsies between March 2005 and September 2021. Patients with solitary bone lesions on CT and sufficient histopathology results were included. Two radiologists categorized the bone lesions using the Bone-RADS (1, benign; 4, malignant). The diagnostic performance of the Bone-RADS was calculated using histopathology results as a standard reference. Inter-reader reliability was calculated.</p><p><strong>Results: </strong>Bone lesions were categorized into two groups: 103 lucent (pathology: 34 benign, 12 intermediate, 54 malignant, and 3 osteomyelitis) and 76 sclerotic/mixed (pathology: 46 benign, 2 intermediate, 26 malignant, and 2 osteomyelitis) lesions. The Bone-RADS for lucent lesions had sensitivities of 95% and 82%, specificities of 11% and 11%, and accuracies of 57% and 50% for readers 1 and 2, respectively. The Bone-RADS for sclerotic/mixed lesions had sensitivities of 75% and 68%, specificities of 27% and 27%, and accuracies of 45% and 42% for readers 1 and 2, respectively. Inter-reader reliability was moderate to very good (κ = 0.744, overall; 0.565, lucent lesions; and 0.851, sclerotic/mixed lesions).</p><p><strong>Conclusion: </strong>Bone-RADS has a high sensitivity for evaluating malignancy in lucent bone lesions and good inter-reader reliability. However, it has poor specificity and accuracy for both lucent and sclerotic/mixed lesions. A possible explanation is that proposed algorithms heavily depend on clinical features such as pain and history of malignancy.</p>","PeriodicalId":21783,"journal":{"name":"Skeletal Radiology","volume":" ","pages":"209-217"},"PeriodicalIF":1.9000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Skeletal Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00256-024-04721-4","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/9 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: To evaluate the diagnostic performance and inter-reader reliability of the Bone Reporting and Data System (Bone-RADS) for solitary bone lesions on CT.
Materials and methods: This retrospective analysis included 179 patients (mean age, 56 ± 18 years; 94 men) who underwent bone biopsies between March 2005 and September 2021. Patients with solitary bone lesions on CT and sufficient histopathology results were included. Two radiologists categorized the bone lesions using the Bone-RADS (1, benign; 4, malignant). The diagnostic performance of the Bone-RADS was calculated using histopathology results as a standard reference. Inter-reader reliability was calculated.
Results: Bone lesions were categorized into two groups: 103 lucent (pathology: 34 benign, 12 intermediate, 54 malignant, and 3 osteomyelitis) and 76 sclerotic/mixed (pathology: 46 benign, 2 intermediate, 26 malignant, and 2 osteomyelitis) lesions. The Bone-RADS for lucent lesions had sensitivities of 95% and 82%, specificities of 11% and 11%, and accuracies of 57% and 50% for readers 1 and 2, respectively. The Bone-RADS for sclerotic/mixed lesions had sensitivities of 75% and 68%, specificities of 27% and 27%, and accuracies of 45% and 42% for readers 1 and 2, respectively. Inter-reader reliability was moderate to very good (κ = 0.744, overall; 0.565, lucent lesions; and 0.851, sclerotic/mixed lesions).
Conclusion: Bone-RADS has a high sensitivity for evaluating malignancy in lucent bone lesions and good inter-reader reliability. However, it has poor specificity and accuracy for both lucent and sclerotic/mixed lesions. A possible explanation is that proposed algorithms heavily depend on clinical features such as pain and history of malignancy.
期刊介绍:
Skeletal Radiology provides a forum for the dissemination of current knowledge and information dealing with disorders of the musculoskeletal system including the spine. While emphasizing the radiological aspects of the many varied skeletal abnormalities, the journal also adopts an interdisciplinary approach, reflecting the membership of the International Skeletal Society. Thus, the anatomical, pathological, physiological, clinical, metabolic and epidemiological aspects of the many entities affecting the skeleton receive appropriate consideration.
This is the Journal of the International Skeletal Society and the Official Journal of the Society of Skeletal Radiology and the Australasian Musculoskelelal Imaging Group.