Managing hemolysis in serum neuron-specific enolase measurements - an automated algorithm for routine practice.

IF 1.3 4区 医学 Q4 MEDICINE, RESEARCH & EXPERIMENTAL
Ragnhild V Nome, Elisabeth Paus, Johanna E Gehin, Nils Bolstad, Trine Bjøro
{"title":"Managing hemolysis in serum neuron-specific enolase measurements - an automated algorithm for routine practice.","authors":"Ragnhild V Nome, Elisabeth Paus, Johanna E Gehin, Nils Bolstad, Trine Bjøro","doi":"10.1080/00365513.2024.2359091","DOIUrl":null,"url":null,"abstract":"<p><p>Neuron-specific enolase (NSE) derived from neurons and peripheral neuroendocrine cells is a biomarker for neuroendocrine tumors and for prognostication in comatose cardiac arrest survivors. However, as platelets and erythrocytes contain NSE, hemolysis causes falsely elevated NSE. We used native serum and hemolysate derived from the same patients to make serial dilutions, and subsequently measured NSE (mNSE) and hemolytic index (HI) in each dilution. An algorithm suitable for the laboratory information system was developed based on the mNSE, HI and the estimated gradient of hemolytic interference from 30 patients. We estimated the associated uncertainty of the corrected NSE (cNSE) results based on the observed range of the gradient and derived an equation for cNSE for samples with limited hemolysis (i.e. 5 < HI ≤ 30): cNSE = mNSE - HI × (0.34 ± 0.23) µg/L. By semi-quantitatively grading the contribution from limited hemolysis, a texted result noting the hemolysis-associated degree of uncertainty can accompany the cNSE result. The major challenge of hemolysis when using serum NSE as a biomarker can be managed using an automated algorithm for correction of NSE results based on degree of hemolysis. However, laboratorians and clinicians should be aware of the limitations associated with <i>in vivo</i> hemolysis.</p>","PeriodicalId":21474,"journal":{"name":"Scandinavian Journal of Clinical & Laboratory Investigation","volume":" ","pages":"225-229"},"PeriodicalIF":1.3000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scandinavian Journal of Clinical & Laboratory Investigation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/00365513.2024.2359091","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/10 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

Neuron-specific enolase (NSE) derived from neurons and peripheral neuroendocrine cells is a biomarker for neuroendocrine tumors and for prognostication in comatose cardiac arrest survivors. However, as platelets and erythrocytes contain NSE, hemolysis causes falsely elevated NSE. We used native serum and hemolysate derived from the same patients to make serial dilutions, and subsequently measured NSE (mNSE) and hemolytic index (HI) in each dilution. An algorithm suitable for the laboratory information system was developed based on the mNSE, HI and the estimated gradient of hemolytic interference from 30 patients. We estimated the associated uncertainty of the corrected NSE (cNSE) results based on the observed range of the gradient and derived an equation for cNSE for samples with limited hemolysis (i.e. 5 < HI ≤ 30): cNSE = mNSE - HI × (0.34 ± 0.23) µg/L. By semi-quantitatively grading the contribution from limited hemolysis, a texted result noting the hemolysis-associated degree of uncertainty can accompany the cNSE result. The major challenge of hemolysis when using serum NSE as a biomarker can be managed using an automated algorithm for correction of NSE results based on degree of hemolysis. However, laboratorians and clinicians should be aware of the limitations associated with in vivo hemolysis.

管理血清神经元特异性烯醇化酶测量中的溶血现象--一种用于常规实践的自动算法。
神经元特异性烯醇化酶(NSE)来源于神经元和外周神经内分泌细胞,是神经内分泌肿瘤的生物标记物,也可用于昏迷的心脏骤停幸存者的预后判断。然而,由于血小板和红细胞中含有 NSE,溶血会导致 NSE 假性升高。我们使用来自同一患者的原生血清和溶血液进行连续稀释,然后测量每个稀释液中的 NSE(mNSE)和溶血指数(HI)。根据 30 名患者的 mNSE、HI 和估计的溶血干扰梯度,我们开发了一种适用于实验室信息系统的算法。我们根据观察到的梯度范围估算了校正 NSE(cNSE)结果的相关不确定性,并推导出了溶血有限样本(即 5 个体内溶血样本)的 cNSE 等式。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.50
自引率
4.80%
发文量
85
审稿时长
4-8 weeks
期刊介绍: The Scandinavian Journal of Clinical and Laboratory Investigation is an international scientific journal covering clinically oriented biochemical and physiological research. Since the launch of the journal in 1949, it has been a forum for international laboratory medicine, closely related to, and edited by, The Scandinavian Society for Clinical Chemistry. The journal contains peer-reviewed articles, editorials, invited reviews, and short technical notes, as well as several supplements each year. Supplements consist of monographs, and symposium and congress reports covering subjects within clinical chemistry and clinical physiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信