Characterization of ribostamycin and its impurities using a nano-quantity analyte detector: Systematic comparison of performance among three different aerosol detectors
{"title":"Characterization of ribostamycin and its impurities using a nano-quantity analyte detector: Systematic comparison of performance among three different aerosol detectors","authors":"Fei Meng , Xiaohua Zhou , Yurong Hou , Haodong Zhao , Jinlin Zhang , Qing Huang , Mei Zhang , Erwin Adams , Yaozuo Yuan , Hai-Wei Shi","doi":"10.1016/j.talanta.2024.126359","DOIUrl":null,"url":null,"abstract":"<div><p>Characterization of aminoglycoside antibiotics like ribostamycin is important due to the complex composition and common toxic impurities. Aerosol detectors are often employed for determination of these non-absorbent analytes. In this work, a robust and cost-effective method was developed for simultaneous detection of ribostamycin and its related substances using high-performance liquid chromatography (HPLC) with a relative new aerosol detector named nano-quantity analyte detector (NQAD). With the introduction of less toxic but more compatible ion-pairs pentafluoropropionic acid (PFPA) and trifluoroacetic acid (TFA) in the eluent, an optimized separation effect was achieved. Compared with the other two aerosol detectors namely ELSD (evaporative light scattering detector) and CAD (charged aerosol detector), method verification and quantitative detection results revealed that NQAD had higher sensitivity than ELSD with a 0.8 μg/mL limit of detection, as well as wider linear range (from 2 μg/mL to 1000 μg/mL) than both CAD (from 2 μg/mL to 200 μg/mL) and ELSD (from 8 μg/mL to 200 μg/mL) detector. The performance of NQAD helped to realize detection of ribostamycin and its impurities with significant concentration differences in a single run. With a cation suppressor to eliminate the ion-suppression caused by the ion-pairs in the eluent, the structure of nine impurities in ribostamycin sample was characterized by liquid chromatography-mass spectrum (LC-MS). Both external standard and area normalization calculation were investigated, and NQAD obtained more accurate results due to its full-range linear response-to-concentration relationship, providing an alternative for routine quality control of multi analyte systems.</p></div>","PeriodicalId":435,"journal":{"name":"Talanta","volume":"277 ","pages":"Article 126359"},"PeriodicalIF":6.7000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0039914024007380","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/5 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Characterization of aminoglycoside antibiotics like ribostamycin is important due to the complex composition and common toxic impurities. Aerosol detectors are often employed for determination of these non-absorbent analytes. In this work, a robust and cost-effective method was developed for simultaneous detection of ribostamycin and its related substances using high-performance liquid chromatography (HPLC) with a relative new aerosol detector named nano-quantity analyte detector (NQAD). With the introduction of less toxic but more compatible ion-pairs pentafluoropropionic acid (PFPA) and trifluoroacetic acid (TFA) in the eluent, an optimized separation effect was achieved. Compared with the other two aerosol detectors namely ELSD (evaporative light scattering detector) and CAD (charged aerosol detector), method verification and quantitative detection results revealed that NQAD had higher sensitivity than ELSD with a 0.8 μg/mL limit of detection, as well as wider linear range (from 2 μg/mL to 1000 μg/mL) than both CAD (from 2 μg/mL to 200 μg/mL) and ELSD (from 8 μg/mL to 200 μg/mL) detector. The performance of NQAD helped to realize detection of ribostamycin and its impurities with significant concentration differences in a single run. With a cation suppressor to eliminate the ion-suppression caused by the ion-pairs in the eluent, the structure of nine impurities in ribostamycin sample was characterized by liquid chromatography-mass spectrum (LC-MS). Both external standard and area normalization calculation were investigated, and NQAD obtained more accurate results due to its full-range linear response-to-concentration relationship, providing an alternative for routine quality control of multi analyte systems.
期刊介绍:
Talanta provides a forum for the publication of original research papers, short communications, and critical reviews in all branches of pure and applied analytical chemistry. Papers are evaluated based on established guidelines, including the fundamental nature of the study, scientific novelty, substantial improvement or advantage over existing technology or methods, and demonstrated analytical applicability. Original research papers on fundamental studies, and on novel sensor and instrumentation developments, are encouraged. Novel or improved applications in areas such as clinical and biological chemistry, environmental analysis, geochemistry, materials science and engineering, and analytical platforms for omics development are welcome.
Analytical performance of methods should be determined, including interference and matrix effects, and methods should be validated by comparison with a standard method, or analysis of a certified reference material. Simple spiking recoveries may not be sufficient. The developed method should especially comprise information on selectivity, sensitivity, detection limits, accuracy, and reliability. However, applying official validation or robustness studies to a routine method or technique does not necessarily constitute novelty. Proper statistical treatment of the data should be provided. Relevant literature should be cited, including related publications by the authors, and authors should discuss how their proposed methodology compares with previously reported methods.