{"title":"Mechanical evaluation of a threaded interference interlocking mechanism for angle-stable intramedullary nailing.","authors":"John Hanlon, Stanley E Kim","doi":"10.2460/ajvr.24.03.0071","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To assess the fatigue and load-to-failure mechanical characteristics of an intramedullary nail with a threaded interference design (TID) in comparison to a commercially available veterinary angle-stable nail with a Morse taper bolt design (I-Loc) of an equivalent size.</p><p><strong>Methods: </strong>10 single interlocking screw/bolt constructs of TID and I-Loc implants were assembled using steel pipe segments and placed through 50,000 cycles of simulated, physiologic axial or torsional loading. Entry torque, postfatigue extraction torque, and 10th, 25,000th, and 50,000th cycle torsional toggle were assessed. Each construct was then loaded to failure in the same respective direction as fatigue testing. Four complete constructs of each design were then assessed using a synthetic bone analog with a 50-mm central defect via nondestructive torsional and axial loading followed by axial load to failure.</p><p><strong>Results: </strong>All constructs were angle stable at all time points and withstood fatigue loading. Median insertional torque, extraction torque-to-insertion torque ratio, and torsional yield load were 33%, 33%, and 72.5% lower, respectively, for the TID interlocking screws. No differences in torsional peak load, torsional stiffness, axial yield load, axial stiffness, or axial peak load were identified. No differences in complete construct angle stability, torsional stiffness, axial peak load, axial stiffness, or axial yield load were identified.</p><p><strong>Clinical relevance: </strong>The TID had an inferior torsional yield load when compared to I-Loc implants but generated angle stability and sustained simulated physiologic fatigue loading. The TID may be a suitable mechanism for generating angle stability in interlocking nails.</p>","PeriodicalId":7754,"journal":{"name":"American journal of veterinary research","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of veterinary research","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.2460/ajvr.24.03.0071","RegionNum":3,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/1 0:00:00","PubModel":"Print","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: To assess the fatigue and load-to-failure mechanical characteristics of an intramedullary nail with a threaded interference design (TID) in comparison to a commercially available veterinary angle-stable nail with a Morse taper bolt design (I-Loc) of an equivalent size.
Methods: 10 single interlocking screw/bolt constructs of TID and I-Loc implants were assembled using steel pipe segments and placed through 50,000 cycles of simulated, physiologic axial or torsional loading. Entry torque, postfatigue extraction torque, and 10th, 25,000th, and 50,000th cycle torsional toggle were assessed. Each construct was then loaded to failure in the same respective direction as fatigue testing. Four complete constructs of each design were then assessed using a synthetic bone analog with a 50-mm central defect via nondestructive torsional and axial loading followed by axial load to failure.
Results: All constructs were angle stable at all time points and withstood fatigue loading. Median insertional torque, extraction torque-to-insertion torque ratio, and torsional yield load were 33%, 33%, and 72.5% lower, respectively, for the TID interlocking screws. No differences in torsional peak load, torsional stiffness, axial yield load, axial stiffness, or axial peak load were identified. No differences in complete construct angle stability, torsional stiffness, axial peak load, axial stiffness, or axial yield load were identified.
Clinical relevance: The TID had an inferior torsional yield load when compared to I-Loc implants but generated angle stability and sustained simulated physiologic fatigue loading. The TID may be a suitable mechanism for generating angle stability in interlocking nails.
期刊介绍:
The American Journal of Veterinary Research supports the collaborative exchange of information between researchers and clinicians by publishing novel research findings that bridge the gulf between basic research and clinical practice or that help to translate laboratory research and preclinical studies to the development of clinical trials and clinical practice. The journal welcomes submission of high-quality original studies and review articles in a wide range of scientific fields, including anatomy, anesthesiology, animal welfare, behavior, epidemiology, genetics, heredity, infectious disease, molecular biology, oncology, pharmacology, pathogenic mechanisms, physiology, surgery, theriogenology, toxicology, and vaccinology. Species of interest include production animals, companion animals, equids, exotic animals, birds, reptiles, and wild and marine animals. Reports of laboratory animal studies and studies involving the use of animals as experimental models of human diseases are considered only when the study results are of demonstrable benefit to the species used in the research or to another species of veterinary interest. Other fields of interest or animals species are not necessarily excluded from consideration, but such reports must focus on novel research findings. Submitted papers must make an original and substantial contribution to the veterinary medicine knowledge base; preliminary studies are not appropriate.