{"title":"Left common carotid urgent reperfusion after inadvertent TEVAR coverage","authors":"Carolyn Postol, Eanas Yassa","doi":"10.1016/j.avsurg.2024.100301","DOIUrl":null,"url":null,"abstract":"<div><p>Type B aortic dissections can carry significant morbidity and mortality when not promptly treated. Although anti-impulse control remains the mainstay treatment of type B aortic dissection, they may often require repair when the dissection becomes complicated or develops high risk features. Thoracic endovascular aortic repair (TEVAR) has been successful for those who require repair but still carry associated procedural risks. Inadvertent coverage of a branch vessel is a rare but serious complication. We describe a case report of a patient with accidental proximal TEVAR deployment resulting in left common carotid artery partial coverage and malperfusion necessitating prompt carotid revascularization with stent placement adjacent to TEVAR.</p></div>","PeriodicalId":72235,"journal":{"name":"Annals of vascular surgery. Brief reports and innovations","volume":"4 2","pages":"Article 100301"},"PeriodicalIF":0.0000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2772687824000539/pdfft?md5=278fd1367f216154d7b15d613a0cffc9&pid=1-s2.0-S2772687824000539-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of vascular surgery. Brief reports and innovations","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772687824000539","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Type B aortic dissections can carry significant morbidity and mortality when not promptly treated. Although anti-impulse control remains the mainstay treatment of type B aortic dissection, they may often require repair when the dissection becomes complicated or develops high risk features. Thoracic endovascular aortic repair (TEVAR) has been successful for those who require repair but still carry associated procedural risks. Inadvertent coverage of a branch vessel is a rare but serious complication. We describe a case report of a patient with accidental proximal TEVAR deployment resulting in left common carotid artery partial coverage and malperfusion necessitating prompt carotid revascularization with stent placement adjacent to TEVAR.
B 型主动脉夹层如不及时治疗,会导致严重的发病率和死亡率。虽然抗冲击控制仍是治疗 B 型主动脉夹层的主要方法,但当夹层变得复杂或出现高风险特征时,患者往往需要进行修复。胸腔内血管主动脉修补术(TEVAR)对需要修补但仍有相关手术风险的患者很有效。意外覆盖分支血管是一种罕见但严重的并发症。我们描述了一例意外近端部署 TEVAR 导致左侧颈总动脉部分覆盖和灌注不良的患者的病例报告,该患者需要在 TEVAR 附近及时进行颈动脉血运重建并置入支架。