Relative contribution of the nail and plate to a nail-plate construct for comminuted distal femoral fractures

IF 2.1 3区 医学 Q2 ORTHOPEDICS
Charles C. Lin, Nicholas Parody, Utkarsh Anil, Kenneth A. Egol
{"title":"Relative contribution of the nail and plate to a nail-plate construct for comminuted distal femoral fractures","authors":"Charles C. Lin,&nbsp;Nicholas Parody,&nbsp;Utkarsh Anil,&nbsp;Kenneth A. Egol","doi":"10.1002/jor.25908","DOIUrl":null,"url":null,"abstract":"<p>The purpose of this study was to assess the biomechanical contributions of the nail and the plate individually to a complete nail-plate construct in the setting of comminuted distal femur fractures. For this biomechanical study, comminuted extra-articular distal femur fractures were created in 24 synthetic osteoporotic femur models. These were then split into three groups: the nail-only group, the plate-only group, and the nail-plate group. After fixation, each specimen underwent sequential axial and torsional loading, and axial and torsional stiffness were calculated and compared. The addition of a nail to a plate-only construct increased axial stiffness by 19.7% and torsional stiffness by 59.4%. The plate-only group and nail-plate group both demonstrated significantly greater axial and torsional stiffness than the nail-only group at all levels of axial and torsional load. (<i>p</i> &lt; 0.001) At 1000 and 2000 N of cyclic loading, the nail-plate group demonstrated significantly greater axial stiffness than the plate-only group (<i>p</i> ≤ 0.018). The nail-plate group demonstrated greater torsional stiffness than the plate-only groups at all levels of torsional loading (<i>p</i> &lt; 0.001). In osteoporotic comminuted distal femur fracture models, most of the axial stiffness in a nail-plate construct comes from the plate. While the combination of the two constructs is not fully additive, the plate contributes the majority of the axial and torsional stiffness in a nail-plate construct. The supplementation of the plate with a nail primarily helps to increase resistance to rotational forces. Level of Evidence: III.</p>","PeriodicalId":16650,"journal":{"name":"Journal of Orthopaedic Research®","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2024-05-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Research®","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jor.25908","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

The purpose of this study was to assess the biomechanical contributions of the nail and the plate individually to a complete nail-plate construct in the setting of comminuted distal femur fractures. For this biomechanical study, comminuted extra-articular distal femur fractures were created in 24 synthetic osteoporotic femur models. These were then split into three groups: the nail-only group, the plate-only group, and the nail-plate group. After fixation, each specimen underwent sequential axial and torsional loading, and axial and torsional stiffness were calculated and compared. The addition of a nail to a plate-only construct increased axial stiffness by 19.7% and torsional stiffness by 59.4%. The plate-only group and nail-plate group both demonstrated significantly greater axial and torsional stiffness than the nail-only group at all levels of axial and torsional load. (p < 0.001) At 1000 and 2000 N of cyclic loading, the nail-plate group demonstrated significantly greater axial stiffness than the plate-only group (p ≤ 0.018). The nail-plate group demonstrated greater torsional stiffness than the plate-only groups at all levels of torsional loading (p < 0.001). In osteoporotic comminuted distal femur fracture models, most of the axial stiffness in a nail-plate construct comes from the plate. While the combination of the two constructs is not fully additive, the plate contributes the majority of the axial and torsional stiffness in a nail-plate construct. The supplementation of the plate with a nail primarily helps to increase resistance to rotational forces. Level of Evidence: III.

在治疗股骨远端粉碎性骨折的钉板结构中,钢钉和钢板的作用相对较大。
本研究的目的是评估在股骨远端粉碎性骨折的情况下,钢钉和钢板各自对完整的钢钉-钢板结构的生物力学贡献。在这项生物力学研究中,我们在 24 个合成骨质疏松股骨模型中制造了粉碎性关节外股骨远端骨折。然后将这些模型分为三组:纯钉组、纯钢板组和钉钢板组。固定后,每个试样依次承受轴向和扭转载荷,并计算和比较轴向和扭转刚度。在纯钢板结构中加入钢钉后,轴向刚度增加了19.7%,扭转刚度增加了59.4%。在所有水平的轴向和扭转载荷下,纯钢板组和钢钉钢板组的轴向和扭转刚度均明显高于纯钢钉组。(p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Orthopaedic Research®
Journal of Orthopaedic Research® 医学-整形外科
CiteScore
6.10
自引率
3.60%
发文量
261
审稿时长
3-6 weeks
期刊介绍: The Journal of Orthopaedic Research is the forum for the rapid publication of high quality reports of new information on the full spectrum of orthopaedic research, including life sciences, engineering, translational, and clinical studies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信