Enhancing biomarker detection in human serum for lung cancer diagnosis: Aqueous biphasic systems for simultaneous depletion of high-abundance proteins and efficient extraction of CYFRA 21–1

IF 5.2 Q1 CHEMISTRY, ANALYTICAL
Marguerita E. Rosa, Maria S.M. Mendes, Diana C.V. Belchior, João A.P. Coutinho, Francisca A. e Silva, Mara G. Freire
{"title":"Enhancing biomarker detection in human serum for lung cancer diagnosis: Aqueous biphasic systems for simultaneous depletion of high-abundance proteins and efficient extraction of CYFRA 21–1","authors":"Marguerita E. Rosa,&nbsp;Maria S.M. Mendes,&nbsp;Diana C.V. Belchior,&nbsp;João A.P. Coutinho,&nbsp;Francisca A. e Silva,&nbsp;Mara G. Freire","doi":"10.1016/j.sampre.2024.100116","DOIUrl":null,"url":null,"abstract":"<div><p>Analysing biomarkers in human serum could be used as an effective and less invasive approach for the diagnosis of lung cancer; however, biomarker detection reliability is highly limited due to matrix effects. Herein, aqueous biphasic systems (ABS) are studied as platforms for human serum pretreatment, allowing the simultaneous depletion of high abundant proteins and biomarker extraction. By using ABS varying the polyethylene glycol (PEG) molecular weight between 400 and 6000 g·mol<sup>−1</sup> and adopting phosphate buffer as the other phase-forming component, the depletion of the high abundance serum proteins immunoglobulin G (IgG) and human serum albumin (HSA) is induced at the ABS interphase, through precipitation, forming a three-phase partitioning system (ABS-TPP). Maximum depletion efficiencies of 99 % for IgG and 70 % for HSA were achieved in one step using PEG 1500-based ABS-TPP. On the other hand, lung cancer biomarkers, such as CYFRA 21–1, are extracted to the PEG-rich phase of the same ABS-TPP with recovery yields of 91 %. This work shows that a proper selection of the PEG molecular weight in the ABS composition leads to the efficient depletion of high-abundance proteins and extraction of cancer biomarkers from human serum, in a single step, confirming the potential of ABS for sample pretreatment to improve biomarker analysis.</p></div>","PeriodicalId":100052,"journal":{"name":"Advances in Sample Preparation","volume":"10 ","pages":"Article 100116"},"PeriodicalIF":5.2000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2772582024000159/pdfft?md5=cc952288acd7046329196162d433f14a&pid=1-s2.0-S2772582024000159-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Sample Preparation","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772582024000159","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Analysing biomarkers in human serum could be used as an effective and less invasive approach for the diagnosis of lung cancer; however, biomarker detection reliability is highly limited due to matrix effects. Herein, aqueous biphasic systems (ABS) are studied as platforms for human serum pretreatment, allowing the simultaneous depletion of high abundant proteins and biomarker extraction. By using ABS varying the polyethylene glycol (PEG) molecular weight between 400 and 6000 g·mol−1 and adopting phosphate buffer as the other phase-forming component, the depletion of the high abundance serum proteins immunoglobulin G (IgG) and human serum albumin (HSA) is induced at the ABS interphase, through precipitation, forming a three-phase partitioning system (ABS-TPP). Maximum depletion efficiencies of 99 % for IgG and 70 % for HSA were achieved in one step using PEG 1500-based ABS-TPP. On the other hand, lung cancer biomarkers, such as CYFRA 21–1, are extracted to the PEG-rich phase of the same ABS-TPP with recovery yields of 91 %. This work shows that a proper selection of the PEG molecular weight in the ABS composition leads to the efficient depletion of high-abundance proteins and extraction of cancer biomarkers from human serum, in a single step, confirming the potential of ABS for sample pretreatment to improve biomarker analysis.

Abstract Image

加强人血清中生物标记物的检测,用于肺癌诊断:同时去除高丰度蛋白质和高效提取 CYFRA 21-1 的双相水溶液系统
分析人血清中的生物标记物可作为诊断肺癌的一种有效且创伤较小的方法;然而,由于基质效应,生物标记物检测的可靠性受到很大限制。本文研究了水性双相系统(ABS)作为人血清预处理平台,可同时去除高含量蛋白质和提取生物标记物。利用聚乙二醇(PEG)分子量在 400 和 6000 g-mol-1 之间变化的 ABS,并采用磷酸盐缓冲液作为另一种成相成分,在 ABS 相间通过沉淀诱导高丰度血清蛋白免疫球蛋白 G(IgG)和人血清白蛋白(HSA)的耗竭,形成三相分配体系(ABS-TPP)。使用基于 PEG 1500 的 ABS-TPP 一步即可实现最高 99% 的 IgG 去除率和 70% 的 HSA 去除率。另一方面,肺癌生物标记物(如 CYFRA 21-1)被提取到同一 ABS-TPP 的富含 PEG 的相中,回收率达到 91%。这项工作表明,适当选择 ABS 成分中的 PEG 分子重量,可在一个步骤中高效去除高丰度蛋白质并提取人血清中的癌症生物标记物,从而证实了 ABS 用于样品预处理以改进生物标记物分析的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.50
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信