U. K. Maity, Namitha Janardhanan, Manoravi Periasamy
{"title":"Quantification of Zr in simulated dissolver solution of U–Zr fuel by laser-induced breakdown spectroscopy","authors":"U. K. Maity, Namitha Janardhanan, Manoravi Periasamy","doi":"10.1515/ract-2023-0208","DOIUrl":null,"url":null,"abstract":"\n Estimation of Zr in fresh and irradiated metal alloy fuel is important. The homogeneous dissolver solution represents the fuel composition better compared to a highly heterogeneous solid pellet. The present study employs LIBS to determine Zr in the simulated dissolver solution. Four different compositions of U–Zr samples where the Zr/U ratio varies from 0.04 to 0.18 % are analyzed by LIBS with an in-house designed liquid sample cell. A good correlation coefficient is achieved for the measurements in the calibration plot. The results for identifying non-overlapping peaks, calibration plot, precision, deviation, and detection limit are discussed in detail. Two set of solid samples, an oxide pellet and metal alloy with similar Zr/U composition, are also analyzed by LIBS. The results obtained from these three set of samples are inter-compared, and the reason for getting a better Zr/U intensity ratio for a dried coating of sample on aluminium for a given composition is explained.","PeriodicalId":21167,"journal":{"name":"Radiochimica Acta","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiochimica Acta","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1515/ract-2023-0208","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, INORGANIC & NUCLEAR","Score":null,"Total":0}
引用次数: 0
Abstract
Estimation of Zr in fresh and irradiated metal alloy fuel is important. The homogeneous dissolver solution represents the fuel composition better compared to a highly heterogeneous solid pellet. The present study employs LIBS to determine Zr in the simulated dissolver solution. Four different compositions of U–Zr samples where the Zr/U ratio varies from 0.04 to 0.18 % are analyzed by LIBS with an in-house designed liquid sample cell. A good correlation coefficient is achieved for the measurements in the calibration plot. The results for identifying non-overlapping peaks, calibration plot, precision, deviation, and detection limit are discussed in detail. Two set of solid samples, an oxide pellet and metal alloy with similar Zr/U composition, are also analyzed by LIBS. The results obtained from these three set of samples are inter-compared, and the reason for getting a better Zr/U intensity ratio for a dried coating of sample on aluminium for a given composition is explained.