Arian Vistamehr , Richard R. Neptune , Christy L. Conroy , Paul A. Freeborn , Gina M. Brunetti , Emily J. Fox
{"title":"Articulated ankle-foot-orthosis improves inter-limb propulsion symmetry during walking adaptability task post-stroke","authors":"Arian Vistamehr , Richard R. Neptune , Christy L. Conroy , Paul A. Freeborn , Gina M. Brunetti , Emily J. Fox","doi":"10.1016/j.clinbiomech.2024.106268","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Community ambulation involves complex walking adaptability tasks such as stepping over obstacles or taking long steps, which require adequate propulsion generation by the trailing leg. Individuals post-stroke often have an increased reliance on their trailing nonparetic leg and favor leading with their paretic leg, which can limit mobility. Ankle-foot-orthoses are prescribed to address common deficits post-stroke such as foot drop and ankle instability. However, it is not clear if walking with an ankle-foot-orthosis improves inter-limb propulsion symmetry during adaptability tasks. This study sought to examine this hypothesis.</p></div><div><h3>Methods</h3><p>Individuals post-stroke (<em>n</em> = 9) that were previously prescribed a custom fabricated plantarflexion-stop articulated ankle-foot-orthosis participated. Participants performed steady-state walking and adaptability tasks overground with and without their orthosis. The adaptability tasks included obstacle crossing and long-step tasks, leading with both their paretic and nonparetic leg. Inter-limb propulsion symmetry was calculated using trailing limb ground-reaction-forces.</p></div><div><h3>Findings</h3><p>During the obstacle crossing task, ankle-foot-orthosis use resulted in a significant improvement in inter-limb propulsion symmetry. The orthosis also improved ankle dorsiflexion during stance, reduced knee hyperextension, increased gastrocnemius muscle activity, and increased peak paretic leg ankle plantarflexor moment. In contrast, there were no differences in propulsion symmetry during steady-state walking and taking a long-step when using the orthosis.</p></div><div><h3>Interpretation</h3><p>Plantarflexion-stop articulated ankle-foot-orthoses can improve propulsion symmetry during obstacle crossing tasks in individuals post-stroke, promoting paretic leg use and reduced reliance on the nonparetic leg.</p></div>","PeriodicalId":50992,"journal":{"name":"Clinical Biomechanics","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-05-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Biomechanics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0268003324001001","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Background
Community ambulation involves complex walking adaptability tasks such as stepping over obstacles or taking long steps, which require adequate propulsion generation by the trailing leg. Individuals post-stroke often have an increased reliance on their trailing nonparetic leg and favor leading with their paretic leg, which can limit mobility. Ankle-foot-orthoses are prescribed to address common deficits post-stroke such as foot drop and ankle instability. However, it is not clear if walking with an ankle-foot-orthosis improves inter-limb propulsion symmetry during adaptability tasks. This study sought to examine this hypothesis.
Methods
Individuals post-stroke (n = 9) that were previously prescribed a custom fabricated plantarflexion-stop articulated ankle-foot-orthosis participated. Participants performed steady-state walking and adaptability tasks overground with and without their orthosis. The adaptability tasks included obstacle crossing and long-step tasks, leading with both their paretic and nonparetic leg. Inter-limb propulsion symmetry was calculated using trailing limb ground-reaction-forces.
Findings
During the obstacle crossing task, ankle-foot-orthosis use resulted in a significant improvement in inter-limb propulsion symmetry. The orthosis also improved ankle dorsiflexion during stance, reduced knee hyperextension, increased gastrocnemius muscle activity, and increased peak paretic leg ankle plantarflexor moment. In contrast, there were no differences in propulsion symmetry during steady-state walking and taking a long-step when using the orthosis.
Interpretation
Plantarflexion-stop articulated ankle-foot-orthoses can improve propulsion symmetry during obstacle crossing tasks in individuals post-stroke, promoting paretic leg use and reduced reliance on the nonparetic leg.
期刊介绍:
Clinical Biomechanics is an international multidisciplinary journal of biomechanics with a focus on medical and clinical applications of new knowledge in the field.
The science of biomechanics helps explain the causes of cell, tissue, organ and body system disorders, and supports clinicians in the diagnosis, prognosis and evaluation of treatment methods and technologies. Clinical Biomechanics aims to strengthen the links between laboratory and clinic by publishing cutting-edge biomechanics research which helps to explain the causes of injury and disease, and which provides evidence contributing to improved clinical management.
A rigorous peer review system is employed and every attempt is made to process and publish top-quality papers promptly.
Clinical Biomechanics explores all facets of body system, organ, tissue and cell biomechanics, with an emphasis on medical and clinical applications of the basic science aspects. The role of basic science is therefore recognized in a medical or clinical context. The readership of the journal closely reflects its multi-disciplinary contents, being a balance of scientists, engineers and clinicians.
The contents are in the form of research papers, brief reports, review papers and correspondence, whilst special interest issues and supplements are published from time to time.
Disciplines covered include biomechanics and mechanobiology at all scales, bioengineering and use of tissue engineering and biomaterials for clinical applications, biophysics, as well as biomechanical aspects of medical robotics, ergonomics, physical and occupational therapeutics and rehabilitation.