The use of happy faces as visual stimuli improves the performance of the hybrid SSVEP+P300 brain computer interface

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS
Deepak D. Kapgate
{"title":"The use of happy faces as visual stimuli improves the performance of the hybrid SSVEP+P300 brain computer interface","authors":"Deepak D. Kapgate","doi":"10.1016/j.jneumeth.2024.110170","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>This study illustrates a hybrid brain-computer interface (BCI) in which steady-state visual evoked potentials (SSVEP) and event-related potentials (P300) are evoked simultaneously. The goal of this study was to improve the performance of the current hybrid SSVEP+P300 BCI systems by incorporating a happy face into visual stimuli.</p></div><div><h3>New method</h3><p>In this study, happy and sad faces were added to a visual stimulus to induce stronger cortical signals in a hybrid SSVEP+P300 BCI. Additionally, we developed a paradigm in which SSVEP responses were triggered by non-face stimuli, whereas P300 responses were triggered by face stimuli. We tested four paradigms: happy face paradigm (HF), sad face paradigm (SF), happy face and flicker paradigm (HFF), and sad face and flicker paradigm (SFF).</p></div><div><h3>Results and conclusions</h3><p>The results demonstrated that the HFF paradigm elicited more robust cortical responses, which resulted in enhanced system accuracy and information transfer rate (ITR). The HFF paradigm has a system communication rate of 25.9 bits per second and an average accuracy of 96.1%. Compared with other paradigms, the HFF paradigm is the best choice for BCI applications because it has the highest ITR and maximum level of comfort.</p></div>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0165027024001158","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

Abstract

Background

This study illustrates a hybrid brain-computer interface (BCI) in which steady-state visual evoked potentials (SSVEP) and event-related potentials (P300) are evoked simultaneously. The goal of this study was to improve the performance of the current hybrid SSVEP+P300 BCI systems by incorporating a happy face into visual stimuli.

New method

In this study, happy and sad faces were added to a visual stimulus to induce stronger cortical signals in a hybrid SSVEP+P300 BCI. Additionally, we developed a paradigm in which SSVEP responses were triggered by non-face stimuli, whereas P300 responses were triggered by face stimuli. We tested four paradigms: happy face paradigm (HF), sad face paradigm (SF), happy face and flicker paradigm (HFF), and sad face and flicker paradigm (SFF).

Results and conclusions

The results demonstrated that the HFF paradigm elicited more robust cortical responses, which resulted in enhanced system accuracy and information transfer rate (ITR). The HFF paradigm has a system communication rate of 25.9 bits per second and an average accuracy of 96.1%. Compared with other paradigms, the HFF paradigm is the best choice for BCI applications because it has the highest ITR and maximum level of comfort.

Abstract Image

使用快乐的面孔作为视觉刺激可提高混合 SSVEP+P300 脑机接口的性能
背景:本研究展示了一种混合型脑机接口(BCI),其中同时诱发稳态视觉诱发电位(SSVEP)和事件相关电位(P300)。本研究的目标是通过在视觉刺激中加入快乐的脸来提高当前混合 SSVEP+P300 BCI 系统的性能:在这项研究中,我们在视觉刺激中加入了快乐和悲伤的面孔,以在混合 SSVEP+P300 BCI 中诱发更强的皮层信号。此外,我们还开发了一种范式,其中SSVEP反应由非人脸刺激触发,而P300反应则由人脸刺激触发。我们测试了四种范式:快乐脸部范式(HF)、悲伤脸部范式(SF)、快乐脸部和闪烁范式(HFF)以及悲伤脸部和闪烁范式(SFF):结果表明,HFF范式能引起更强的皮层反应,从而提高系统的准确性和信息传递率(ITR)。HFF 范式的系统通信速率为每秒 25.9 比特,平均准确率为 96.1%。与其他范式相比,HFF 范式具有最高的信息传输率和最大程度的舒适性,因此是 BCI 应用的最佳选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信