Differentiating Nylon Samples with Visually Indistinguishable Fluorescence Using Principal Component Analysis and Common Dimension Partial Least Squares Linear Discriminant Analysis with Synchronous Fluorescence Spectroscopy.

IF 2.2 3区 化学 Q2 INSTRUMENTS & INSTRUMENTATION
Applied Spectroscopy Pub Date : 2024-09-01 Epub Date: 2024-05-22 DOI:10.1177/00037028241255150
Noah M Froelich, Silvana M Azcarate, Héctor C Goicoechea, Andrés D Campiglia
{"title":"Differentiating Nylon Samples with Visually Indistinguishable Fluorescence Using Principal Component Analysis and Common Dimension Partial Least Squares Linear Discriminant Analysis with Synchronous Fluorescence Spectroscopy.","authors":"Noah M Froelich, Silvana M Azcarate, Héctor C Goicoechea, Andrés D Campiglia","doi":"10.1177/00037028241255150","DOIUrl":null,"url":null,"abstract":"<p><p>Fluorescence spectroscopy is an attractive candidate for analyzing samples of nylon. Impurities within the polymers formed during the synthesis and processing of nylons give rise to the observed fluorescence, allowing for nylons to be analyzed based on their impurities. Nylons from the same source are expected to display similar fluorescence profiles, and nylons with different fluorescence are expected to be from different sources. This paper investigates an important case where different nylons displayed similar fluorescence, preventing easy discrimination. Samples of Nylon 6 and Nylon 6/12 had visually indistinguishable excitation-emission matrices (EEM), excitation spectra, fluorescence spectra, and synchronous fluorescence spectra at larger Δλ. By collecting synchronous fluorescence spectra at smaller Δλ, additional features in the fluorescence profiles were identified that allowed for some discrimination between the two nylons. Combining the EEM and synchronous fluorescence data with chemometric algorithms provided a clearer differentiation between the two nylons. parallel factor analysis, principal component analysis, and common dimension partial least squares (ComDim-PLS) showed two distinct clusters in the data, with ComDim-PLS providing the greatest distinction between the clusters. The loadings revealed the variables of interest to the ComDim-PLS were the 400 nm and 335 nm bands for all synchronous fluorescence spectra, the 460 nm and 310 nm bands for the Δλ = 20 nm and Δλ = 30 nm synchronous fluorescence spectra, and the 440 nm band for the Δλ = 20 nm synchronous fluorescence spectra. The linear discriminant analysis performed with the PLS data yielded a classification accuracy of 95% with the EEM data and 100% with the synchronous fluorescence data, displaying the power of this technique to differentiate two different nylons with visually indistinguishable fluorescence spectra.</p>","PeriodicalId":8253,"journal":{"name":"Applied Spectroscopy","volume":" ","pages":"962-973"},"PeriodicalIF":2.2000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Spectroscopy","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1177/00037028241255150","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/22 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

Fluorescence spectroscopy is an attractive candidate for analyzing samples of nylon. Impurities within the polymers formed during the synthesis and processing of nylons give rise to the observed fluorescence, allowing for nylons to be analyzed based on their impurities. Nylons from the same source are expected to display similar fluorescence profiles, and nylons with different fluorescence are expected to be from different sources. This paper investigates an important case where different nylons displayed similar fluorescence, preventing easy discrimination. Samples of Nylon 6 and Nylon 6/12 had visually indistinguishable excitation-emission matrices (EEM), excitation spectra, fluorescence spectra, and synchronous fluorescence spectra at larger Δλ. By collecting synchronous fluorescence spectra at smaller Δλ, additional features in the fluorescence profiles were identified that allowed for some discrimination between the two nylons. Combining the EEM and synchronous fluorescence data with chemometric algorithms provided a clearer differentiation between the two nylons. parallel factor analysis, principal component analysis, and common dimension partial least squares (ComDim-PLS) showed two distinct clusters in the data, with ComDim-PLS providing the greatest distinction between the clusters. The loadings revealed the variables of interest to the ComDim-PLS were the 400 nm and 335 nm bands for all synchronous fluorescence spectra, the 460 nm and 310 nm bands for the Δλ = 20 nm and Δλ = 30 nm synchronous fluorescence spectra, and the 440 nm band for the Δλ = 20 nm synchronous fluorescence spectra. The linear discriminant analysis performed with the PLS data yielded a classification accuracy of 95% with the EEM data and 100% with the synchronous fluorescence data, displaying the power of this technique to differentiate two different nylons with visually indistinguishable fluorescence spectra.

利用主成分分析和共维偏最小二乘法线性判别分析与同步荧光光谱法区分具有肉眼难以区分的荧光的尼龙样品。
荧光光谱法是分析尼龙样品的一种极具吸引力的方法。尼龙合成和加工过程中形成的聚合物中的杂质会产生荧光,因此可以根据杂质对尼龙进行分析。来自同一来源的尼龙预计会显示出相似的荧光曲线,而荧光不同的尼龙预计来自不同的来源。本文研究了一个重要案例,在该案例中,不同的尼龙显示出相似的荧光,因此不易区分。尼龙 6 和尼龙 6/12 样品的激发-发射矩阵 (EEM)、激发光谱、荧光光谱和较大 Δλ 时的同步荧光光谱在视觉上难以区分。通过收集较小Δλ时的同步荧光光谱,可以发现荧光曲线中的其他特征,从而在一定程度上区分两种尼龙。并行因子分析、主成分分析和共维偏最小二乘法(ComDim-PLS)显示数据中有两个不同的群组,其中共维偏最小二乘法在群组间的区分度最大。载荷显示,ComDim-PLS 所关注的变量是所有同步荧光光谱的 400 nm 和 335 nm 波段,Δλ = 20 nm 和 Δλ = 30 nm 同步荧光光谱的 460 nm 和 310 nm 波段,以及 Δλ = 20 nm 同步荧光光谱的 440 nm 波段。利用 PLS 数据进行的线性判别分析得出,EEM 数据的分类准确率为 95%,同步荧光数据的分类准确率为 100%,这表明该技术能够区分两种荧光光谱在视觉上无法区分的不同尼龙。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Applied Spectroscopy
Applied Spectroscopy 工程技术-光谱学
CiteScore
6.60
自引率
5.70%
发文量
139
审稿时长
3.5 months
期刊介绍: Applied Spectroscopy is one of the world''s leading spectroscopy journals, publishing high-quality peer-reviewed articles, both fundamental and applied, covering all aspects of spectroscopy. Established in 1951, the journal is owned by the Society for Applied Spectroscopy and is published monthly. The journal is dedicated to fulfilling the mission of the Society to “…advance and disseminate knowledge and information concerning the art and science of spectroscopy and other allied sciences.”
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信