A comparison of gelatine surrogates for wound track assessment.

IF 2.2 3区 医学 Q1 MEDICINE, LEGAL
International Journal of Legal Medicine Pub Date : 2024-09-01 Epub Date: 2024-05-22 DOI:10.1007/s00414-024-03221-3
Cynthia Bir, Adam Menkara, Rodrigo Villalta, Michele Bodo, Sebastien Roth, Don Sherman
{"title":"A comparison of gelatine surrogates for wound track assessment.","authors":"Cynthia Bir, Adam Menkara, Rodrigo Villalta, Michele Bodo, Sebastien Roth, Don Sherman","doi":"10.1007/s00414-024-03221-3","DOIUrl":null,"url":null,"abstract":"<p><p>The use of ordnance gelatine has been widespread in the field of ballistics as a simulant for soft tissue when assessing ballistic threats. However, the traditional method of preparing ordnance gelatine is time-consuming and requires precision to ensure that the final mold meets the required specifications. Furthermore, temperature control is necessary post-production, and there are limitations on its usage duration. To address these issues, manufacturers have developed pre-mixed, gelatine-like products that are stable at room temperature and require less preparation time. Nonetheless, it is uncertain whether these new products can perform in the same manner as the gold standard of ordnance gelatine. This study used five types of blocks, including ordnance gelatine (10% and 20%), Clear Ballistics (10% and 20%) and Perma-Gel (10%) and subjected them to 9 mm, 0.380 Auto fired from a universal receiver and a 5.56 × 45 mm ammunition fired by a certified firearms instructor. Delta-V and total energy dissipation were measured after each test using data collected from ballistic chronographs placed in front of and behind each block. High-speed video was recorded, and a cut-down analysis conducted. The findings revealed variations in energy dissipation and fissure formation within the block, with greater energy based on fissure formation observed in the ordnance gelatine. Additionally, the high-speed video showed the occurrence of secondary combustions occurring in the premixed gelatines.</p>","PeriodicalId":14071,"journal":{"name":"International Journal of Legal Medicine","volume":null,"pages":null},"PeriodicalIF":2.2000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Legal Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00414-024-03221-3","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/22 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"MEDICINE, LEGAL","Score":null,"Total":0}
引用次数: 0

Abstract

The use of ordnance gelatine has been widespread in the field of ballistics as a simulant for soft tissue when assessing ballistic threats. However, the traditional method of preparing ordnance gelatine is time-consuming and requires precision to ensure that the final mold meets the required specifications. Furthermore, temperature control is necessary post-production, and there are limitations on its usage duration. To address these issues, manufacturers have developed pre-mixed, gelatine-like products that are stable at room temperature and require less preparation time. Nonetheless, it is uncertain whether these new products can perform in the same manner as the gold standard of ordnance gelatine. This study used five types of blocks, including ordnance gelatine (10% and 20%), Clear Ballistics (10% and 20%) and Perma-Gel (10%) and subjected them to 9 mm, 0.380 Auto fired from a universal receiver and a 5.56 × 45 mm ammunition fired by a certified firearms instructor. Delta-V and total energy dissipation were measured after each test using data collected from ballistic chronographs placed in front of and behind each block. High-speed video was recorded, and a cut-down analysis conducted. The findings revealed variations in energy dissipation and fissure formation within the block, with greater energy based on fissure formation observed in the ordnance gelatine. Additionally, the high-speed video showed the occurrence of secondary combustions occurring in the premixed gelatines.

Abstract Image

用于评估伤口痕迹的明胶替代物比较。
在弹道学领域,军械明胶作为评估弹道威胁时的软组织模拟物已被广泛使用。然而,传统的军械明胶制备方法非常耗时,而且要求精确,以确保最终模具符合所需的规格。此外,生产后还必须进行温度控制,而且使用时间也有限制。为了解决这些问题,制造商开发了预混合的类似明胶的产品,这些产品在室温下稳定,所需的准备时间也较短。然而,这些新产品的性能是否能与军械明胶的黄金标准相媲美,目前尚不确定。这项研究使用了五种类型的试块,包括军械明胶(10% 和 20%)、Clear Ballistics(10% 和 20%)和 Perma-Gel(10%),并对它们进行了测试,测试对象是通用接收器发射的 9 毫米、0.380 自动手枪弹,以及经认证的枪械教练发射的 5.56 × 45 毫米弹药。每次测试后,都会使用放置在每个弹块前后的弹道计时器收集的数据测量 Delta-V 和总能量消耗。还录制了高速视频,并进行了缩减分析。研究结果表明,能量耗散和弹块内部裂缝的形成存在差异,在军械明胶中观察到的裂缝形成所产生的能量更大。此外,高速视频还显示预混合明胶发生了二次燃烧。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.80
自引率
9.50%
发文量
165
审稿时长
1 months
期刊介绍: The International Journal of Legal Medicine aims to improve the scientific resources used in the elucidation of crime and related forensic applications at a high level of evidential proof. The journal offers review articles tracing development in specific areas, with up-to-date analysis; original articles discussing significant recent research results; case reports describing interesting and exceptional examples; population data; letters to the editors; and technical notes, which appear in a section originally created for rapid publication of data in the dynamic field of DNA analysis.
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信