{"title":"Enhanced 1D photonic crystal biosensor for blood components and blood infection detection","authors":"Donia M. Nasr,&nbsp;Samia I. Mostafa,&nbsp;Mona A. El Naggar","doi":"10.1140/epjd/s10053-024-00838-2","DOIUrl":null,"url":null,"abstract":"<div><p>The present work proposes a unidimensional asymmetric photonic crystal (1D PhC) sensor suitable for detecting blood components for both healthy and infected conditions. The proposed design is an enhanced efficient biosensor that distinguishes <i>five</i> blood components, namely; platelets, plasma, haemoglobin, RBCs and WBCs. The present work biosensor is designed as N binary nanostructured layers of SiO<sub>2</sub> and PbS, with a defect layer, <i>D</i>, to form an asymmetric (<i>P</i>|<i>Q</i>)<sup><i>N</i>/2</sup><i>D</i> (<i>P</i>|<i>Q</i>)<sup><i>N</i>/2</sup> model. Infrared radiation is directed on the PhC in two cases: (i) normal incidence and (ii) oblique incidence with transverse electric mode (TEM) and transverse magnetic mode (TMM). The EMW propagation through the PhC layers is simulated using the well-established transfer matrix that is implemented using MATLAB software. The present work PhC design produces output transmission pulse peaks for all samples under investigation, both healthy and infected. The sensitivity, <i>S</i>, FoM, FWHM and <i>Q</i><sub>f</sub> are calculated to assess the proposed biosensor performance. The presented biosensor exhibits better sensitivity (<i>S</i>), in the case of oblique incidence (TEM) than the normal incidence. Moreover, the performance of the proposed biosensor is validated by calculating another type of sensitivity (<i>S</i>′) for the five infected blood-component samples when related to their corresponding healthy ones. Furthermore, the variation of sensitivity with the angle of incidence is investigated showing a significant rise in the sensitivity with the increase in the incident angle. The proposed biosensor exhibits maximum sensitivity; <i>S</i><sub>max</sub> = 625.0 nm/RIU for infected plasma in the case of normal incidence, while <i>S</i><sub>max</sub> = 1025.4 nm/RIU for infected Hb (TEM) and <i>S</i><sub>max</sub> = 675.0 nm/RIU for infected WBCs (TMM). The proposed PhC biosensor is capable of early detection of some diseases such as leukaemia, dengue virus and malaria. The proposed biosensor performance is compared to recent literature exhibiting higher sensitivity, thus presenting an accurate method of further blood disease detection.</p><h3>Graphical abstract</h3>\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>","PeriodicalId":789,"journal":{"name":"The European Physical Journal D","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2024-05-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The European Physical Journal D","FirstCategoryId":"4","ListUrlMain":"https://link.springer.com/article/10.1140/epjd/s10053-024-00838-2","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPTICS","Score":null,"Total":0}
引用次数: 0

Abstract

The present work proposes a unidimensional asymmetric photonic crystal (1D PhC) sensor suitable for detecting blood components for both healthy and infected conditions. The proposed design is an enhanced efficient biosensor that distinguishes five blood components, namely; platelets, plasma, haemoglobin, RBCs and WBCs. The present work biosensor is designed as N binary nanostructured layers of SiO2 and PbS, with a defect layer, D, to form an asymmetric (P|Q)N/2D (P|Q)N/2 model. Infrared radiation is directed on the PhC in two cases: (i) normal incidence and (ii) oblique incidence with transverse electric mode (TEM) and transverse magnetic mode (TMM). The EMW propagation through the PhC layers is simulated using the well-established transfer matrix that is implemented using MATLAB software. The present work PhC design produces output transmission pulse peaks for all samples under investigation, both healthy and infected. The sensitivity, S, FoM, FWHM and Qf are calculated to assess the proposed biosensor performance. The presented biosensor exhibits better sensitivity (S), in the case of oblique incidence (TEM) than the normal incidence. Moreover, the performance of the proposed biosensor is validated by calculating another type of sensitivity (S′) for the five infected blood-component samples when related to their corresponding healthy ones. Furthermore, the variation of sensitivity with the angle of incidence is investigated showing a significant rise in the sensitivity with the increase in the incident angle. The proposed biosensor exhibits maximum sensitivity; Smax = 625.0 nm/RIU for infected plasma in the case of normal incidence, while Smax = 1025.4 nm/RIU for infected Hb (TEM) and Smax = 675.0 nm/RIU for infected WBCs (TMM). The proposed PhC biosensor is capable of early detection of some diseases such as leukaemia, dengue virus and malaria. The proposed biosensor performance is compared to recent literature exhibiting higher sensitivity, thus presenting an accurate method of further blood disease detection.

Graphical abstract

Abstract Image

Abstract Image

用于检测血液成分和血液感染的增强型一维光子晶体生物传感器
本研究提出了一种单维非对称光子晶体(1D PhC)传感器,适用于检测健康和感染情况下的血液成分。所提出的设计是一种增强型高效生物传感器,可区分五种血液成分,即血小板、血浆、血红蛋白、红细胞和白细胞。本作品中的生物传感器设计为 N 个二元纳米结构的二氧化硅层和碳化铅层,再加上一个缺陷层 D,形成一个不对称的 (P|Q)N/2D (P|Q)N/2 模型。红外辐射在两种情况下照射 PhC:(i) 正常入射和 (ii) 具有横向电模(TEM)和横向磁模(TMM)的斜入射。电磁波在 PhC 层中的传播是通过使用 MATLAB 软件实现的成熟传递矩阵进行模拟的。本研究的 PhC 设计可为所有被研究样本(包括健康样本和感染样本)产生输出传输脉冲峰值。通过计算灵敏度、S、FoM、FWHM 和 Qf 来评估所提出的生物传感器的性能。所提出的生物传感器在斜入射(TEM)情况下比正常入射情况下表现出更好的灵敏度(S)。此外,通过计算五种受感染血液成分样本与相应健康样本的另一种灵敏度(S′),验证了所提出的生物传感器的性能。此外,还研究了灵敏度随入射角度的变化,结果表明,随着入射角度的增加,灵敏度也显著提高。在正常入射情况下,拟议的生物传感器显示出最大灵敏度;受感染血浆的 Smax = 625.0 nm/RIU,受感染血红蛋白(TEM)的 Smax = 1025.4 nm/RIU,受感染白细胞(TMM)的 Smax = 675.0 nm/RIU。拟议的 PhC 生物传感器能够早期检测一些疾病,如白血病、登革热病毒和疟疾。与最近的文献相比,所提出的生物传感器具有更高的灵敏度,从而为进一步检测血液疾病提供了一种准确的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
The European Physical Journal D
The European Physical Journal D 物理-物理:原子、分子和化学物理
CiteScore
3.10
自引率
11.10%
发文量
213
审稿时长
3 months
期刊介绍: The European Physical Journal D (EPJ D) presents new and original research results in: Atomic Physics; Molecular Physics and Chemical Physics; Atomic and Molecular Collisions; Clusters and Nanostructures; Plasma Physics; Laser Cooling and Quantum Gas; Nonlinear Dynamics; Optical Physics; Quantum Optics and Quantum Information; Ultraintense and Ultrashort Laser Fields. The range of topics covered in these areas is extensive, from Molecular Interaction and Reactivity to Spectroscopy and Thermodynamics of Clusters, from Atomic Optics to Bose-Einstein Condensation to Femtochemistry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信