Minimum Shear Reinforcement for Reactive Powder Concrete Beams

Eng Pub Date : 2024-05-08 DOI:10.3390/eng5020043
Hussein Kareem Sultan, Ghasan Fahim Huseien
{"title":"Minimum Shear Reinforcement for Reactive Powder Concrete Beams","authors":"Hussein Kareem Sultan, Ghasan Fahim Huseien","doi":"10.3390/eng5020043","DOIUrl":null,"url":null,"abstract":"The aim of this research was to determine the minimal requirements for shear reinforcement for reactive powder concrete (RPC) rectangular cross-sectional beams with a compressive strength of 157 MPa and a steel fiber volume content of 2.0% that remained constant for all the tested beams. Additionally, the recommendations of KCI-2012 and AFGC-2013 for the design of RPC beams as well as the shear design requirements of ACI 314-2014 when applied to RPC beams were studied. Utilizing a three-dimensional finite element program, a computational model was designed for forecasting the deformations and shear strength of the examined RPC beams. Both the shear-span-to-depth relationship (a/d) and the minimal reinforcement web ratio, represented by the distance between stirrups and the diameter of the stirrup bars, are the key study parameters in this regard. According to this study’s experimental findings, increasing the given reinforcement of the web ratio has little influence on both the ultimate shear strength as well as the diagonal cracking strength of the beams. Additionally, the findings demonstrated that the ACI 318-2014 maximum stirrup spacing requirement of 0.5 d can safely be extended to 0.75 d for beams that are relatively short. Compared to what ACI 318-2014 mandates, the suggestions of AFGC-2013 and KCI-2012 are more cautious and safe. According to the AFGC-2013 criteria, the mean proportion of Vfb to projected Vu,AFGC is roughly 58.3%, whereas the mean proportion of vs. and Vc is just 41.7%. The deformation response and ultimate shear strength of the examined RPC beams were well predicted by the designed model using finite elements when metal fibers were taken into account.","PeriodicalId":502660,"journal":{"name":"Eng","volume":" 12","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-05-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eng","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/eng5020043","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The aim of this research was to determine the minimal requirements for shear reinforcement for reactive powder concrete (RPC) rectangular cross-sectional beams with a compressive strength of 157 MPa and a steel fiber volume content of 2.0% that remained constant for all the tested beams. Additionally, the recommendations of KCI-2012 and AFGC-2013 for the design of RPC beams as well as the shear design requirements of ACI 314-2014 when applied to RPC beams were studied. Utilizing a three-dimensional finite element program, a computational model was designed for forecasting the deformations and shear strength of the examined RPC beams. Both the shear-span-to-depth relationship (a/d) and the minimal reinforcement web ratio, represented by the distance between stirrups and the diameter of the stirrup bars, are the key study parameters in this regard. According to this study’s experimental findings, increasing the given reinforcement of the web ratio has little influence on both the ultimate shear strength as well as the diagonal cracking strength of the beams. Additionally, the findings demonstrated that the ACI 318-2014 maximum stirrup spacing requirement of 0.5 d can safely be extended to 0.75 d for beams that are relatively short. Compared to what ACI 318-2014 mandates, the suggestions of AFGC-2013 and KCI-2012 are more cautious and safe. According to the AFGC-2013 criteria, the mean proportion of Vfb to projected Vu,AFGC is roughly 58.3%, whereas the mean proportion of vs. and Vc is just 41.7%. The deformation response and ultimate shear strength of the examined RPC beams were well predicted by the designed model using finite elements when metal fibers were taken into account.
反应粉末混凝土梁的最小抗剪钢筋
本研究旨在确定抗压强度为 157 兆帕、钢纤维体积含量为 2.0%(所有测试梁均保持不变)的活性粉末混凝土(RPC)矩形截面梁对剪力配筋的最低要求。此外,还研究了 KCI-2012 和 AFGC-2013 对 RPC 梁设计的建议,以及 ACI 314-2014 中适用于 RPC 梁的剪力设计要求。利用三维有限元程序设计了一个计算模型,用于预测受检 RPC 梁的变形和抗剪强度。剪切跨度与深度关系(a/d)和最小钢筋腹板比(由箍筋间距和箍筋直径表示)是这方面的关键研究参数。根据本研究的实验结果,增加腹板配筋率对梁的极限剪切强度和斜向开裂强度影响不大。此外,研究结果表明,对于相对较短的梁,ACI 318-2014 的最大箍筋间距要求 0.5 d 可以安全地扩展到 0.75 d。与 ACI 318-2014 的规定相比,AFGC-2013 和 KCI-2012 的建议更为谨慎和安全。根据 AFGC-2013 标准,Vfb 与预计 Vu 的平均比例约为 58.3%,而 vs. 与 Vc 的平均比例仅为 41.7%。在考虑金属纤维的情况下,使用有限元设计的模型可以很好地预测受检 RPC 梁的变形响应和极限抗剪强度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Eng
Eng
CiteScore
2.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信