Water Quality and the First-Flush Effect in Roof-Based Rainwater Harvesting, Part II: First Flush

Water Pub Date : 2024-05-16 DOI:10.3390/w16101421
Jessica J. Lay, Jason R. Vogel, Jason B. Belden, Glenn O. Brown, Daniel E. Storm
{"title":"Water Quality and the First-Flush Effect in Roof-Based Rainwater Harvesting, Part II: First Flush","authors":"Jessica J. Lay, Jason R. Vogel, Jason B. Belden, Glenn O. Brown, Daniel E. Storm","doi":"10.3390/w16101421","DOIUrl":null,"url":null,"abstract":"Rainwater runoff samples from a range of roofing materials were temporally collected from 19 small-scale roof structures and two commercial buildings through simulated and actual storm events, and the concentrations of polycyclic aromatic hydrocarbons (PAHs), phosphorus flame retardants (PFLs), and pyrethroid insecticides and other water quality parameters were analyzed. In Part I of this research, the concentrations of these contaminants in roof runoff and soils receiving runoff from a range of roofing materials were evaluated. In Part II, recommendations have been developed for a first-flush exclusion to improve the quality of water harvesting for nonpotable uses. Recommendations focus on a first-flush diversion based on mass removals of total suspended solids (TSS) and PAHs linked to conductivity measurements throughout a storm event. Additionally, an upper-confidence limit (UCL) was constructed to determine the minimum diversion required to obtain 50, 75, 90, and 95% mass removal of TSS and PAH contaminants. The majority of TSS were produced during the initial 1.2 mm of runoff. Likewise, the majority of PAHs were removed during the initial 1.2 mm of runoff, except for the asphalt shingle roofs, where high PAHs were observed after 6 mm of runoff. The Texas Water Development Board (TWDB)-recommended first-flush diversion of one gallon for every 100 square feet of rooftop was not always adequate for removing 50% of TSS and PAHs from the roofs. Rainwater runoff conductivity decreased drastically between 1.2 to 2.4 mm of rainwater runoff. Diverting the first flush based on conductivity has the potential to also divert the majority of TSS and PAHs in roof runoff.","PeriodicalId":509004,"journal":{"name":"Water","volume":"37 2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Water","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/w16101421","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Rainwater runoff samples from a range of roofing materials were temporally collected from 19 small-scale roof structures and two commercial buildings through simulated and actual storm events, and the concentrations of polycyclic aromatic hydrocarbons (PAHs), phosphorus flame retardants (PFLs), and pyrethroid insecticides and other water quality parameters were analyzed. In Part I of this research, the concentrations of these contaminants in roof runoff and soils receiving runoff from a range of roofing materials were evaluated. In Part II, recommendations have been developed for a first-flush exclusion to improve the quality of water harvesting for nonpotable uses. Recommendations focus on a first-flush diversion based on mass removals of total suspended solids (TSS) and PAHs linked to conductivity measurements throughout a storm event. Additionally, an upper-confidence limit (UCL) was constructed to determine the minimum diversion required to obtain 50, 75, 90, and 95% mass removal of TSS and PAH contaminants. The majority of TSS were produced during the initial 1.2 mm of runoff. Likewise, the majority of PAHs were removed during the initial 1.2 mm of runoff, except for the asphalt shingle roofs, where high PAHs were observed after 6 mm of runoff. The Texas Water Development Board (TWDB)-recommended first-flush diversion of one gallon for every 100 square feet of rooftop was not always adequate for removing 50% of TSS and PAHs from the roofs. Rainwater runoff conductivity decreased drastically between 1.2 to 2.4 mm of rainwater runoff. Diverting the first flush based on conductivity has the potential to also divert the majority of TSS and PAHs in roof runoff.
屋顶雨水收集的水质和首冲效应,第二部分:首冲
通过模拟和实际暴雨事件,从 19 个小型屋顶结构和两座商业建筑中收集了各种屋顶材料的雨水径流样本,并分析了多环芳烃 (PAH)、磷阻燃剂 (PFL) 和拟除虫菊酯杀虫剂的浓度以及其他水质参数。研究的第一部分评估了这些污染物在屋顶径流和接收各种屋顶材料径流的土壤中的浓度。在第二部分中,为改善非饮用水集水的水质,提出了首冲排除建议。建议的重点是根据总悬浮固体 (TSS) 和多环芳烃 (PAHs) 的质量去除率以及整个暴雨过程中的电导率测量结果进行首冲分流。此外,还构建了一个置信上限 (UCL),以确定获得 50%、75%、90% 和 95% 的总悬浮固体和 PAH 污染物质量去除率所需的最小分流量。大部分 TSS 是在最初 1.2 毫米的径流中产生的。同样,大部分 PAHs 也是在最初的 1.2 毫米径流中被去除的,但沥青瓦屋顶除外,在 6 毫米径流之后,PAHs 含量较高。得克萨斯州水资源开发委员会(TWDB)建议的每 100 平方英尺屋顶一加仑的首冲引水量并不总是足以去除屋顶上 50% 的 TSS 和 PAHs。在 1.2 至 2.4 毫米的雨水径流之间,雨水径流传导性急剧下降。根据电导率来分流第一股雨水也有可能分流屋顶径流中的大部分 TSS 和 PAHs。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书