The Estimated Fick Method Systematically Over-Estimates Cardiac Index Compared to Thermodilution in Children.

IF 1.5 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Pediatric Cardiology Pub Date : 2025-03-01 Epub Date: 2024-05-18 DOI:10.1007/s00246-024-03491-z
Andrew A Lawson, Paul Tannous, Christina Laternser, Karl Migally
{"title":"The Estimated Fick Method Systematically Over-Estimates Cardiac Index Compared to Thermodilution in Children.","authors":"Andrew A Lawson, Paul Tannous, Christina Laternser, Karl Migally","doi":"10.1007/s00246-024-03491-z","DOIUrl":null,"url":null,"abstract":"<p><p>Cardiac index (CI) may be derived from the Fick method, using measured or estimated oxygen consumption (VO<sub>2</sub>), or from thermodilution. In children, LaFarge VO<sub>2</sub> estimates correlate poorly with measured VO<sub>2</sub> values. In a large adult cohort, there was only modest correlation between estimated Fick CI (eFick CI) and thermodilution CI (TDCI). We evaluated the extent of agreement between eFick CI using LaFarge estimates of VO<sub>2</sub> and TDCI in a pediatric cohort. A retrospective, single-center chart review of patients 3-18 years of age who underwent cardiac catheterization with documented eFick CI and TDCI from 2004 to 2020 included 201 catheterizations from 161 unique patients. The mean patient age at catheterization was 12.2y (SD 4.4y). The most frequent diagnosis was cardiomyopathy, followed by congenital heart disease and pulmonary hypertension. TDCI and eFick CI differed by > 20% in 49% of catheterizations. eFick CI systematically exceeded TDCI by a mean percentage difference of 24% (SD 31%). Higher mean CI ((eFick CI + TDCI)/2) and older age were predictive of greater percent difference between eFick CI and TDCI. For each increase in mean CI by 1.0 L/min/m<sup>2</sup>, the expected percent difference in CI increased by 9.9% (p < 0.001). In pediatric patients undergoing cardiac catheterization, eFick CI with LaFarge VO<sub>2</sub> systematically exceeds TDCI. The difference between methods is frequently > 20%, which may have clinically significant implications. Discrepancies between eFick CI and TDCI increase at higher mean CI.</p>","PeriodicalId":19814,"journal":{"name":"Pediatric Cardiology","volume":" ","pages":"713-718"},"PeriodicalIF":1.5000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pediatric Cardiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00246-024-03491-z","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/18 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Cardiac index (CI) may be derived from the Fick method, using measured or estimated oxygen consumption (VO2), or from thermodilution. In children, LaFarge VO2 estimates correlate poorly with measured VO2 values. In a large adult cohort, there was only modest correlation between estimated Fick CI (eFick CI) and thermodilution CI (TDCI). We evaluated the extent of agreement between eFick CI using LaFarge estimates of VO2 and TDCI in a pediatric cohort. A retrospective, single-center chart review of patients 3-18 years of age who underwent cardiac catheterization with documented eFick CI and TDCI from 2004 to 2020 included 201 catheterizations from 161 unique patients. The mean patient age at catheterization was 12.2y (SD 4.4y). The most frequent diagnosis was cardiomyopathy, followed by congenital heart disease and pulmonary hypertension. TDCI and eFick CI differed by > 20% in 49% of catheterizations. eFick CI systematically exceeded TDCI by a mean percentage difference of 24% (SD 31%). Higher mean CI ((eFick CI + TDCI)/2) and older age were predictive of greater percent difference between eFick CI and TDCI. For each increase in mean CI by 1.0 L/min/m2, the expected percent difference in CI increased by 9.9% (p < 0.001). In pediatric patients undergoing cardiac catheterization, eFick CI with LaFarge VO2 systematically exceeds TDCI. The difference between methods is frequently > 20%, which may have clinically significant implications. Discrepancies between eFick CI and TDCI increase at higher mean CI.

Abstract Image

与热稀释法相比,估计菲克法系统性地高估了儿童的心脏指数。
心脏指数(CI)可通过菲克法、测量或估算的耗氧量(VO2)或热稀释法得出。在儿童中,LaFarge VO2 估计值与测量的 VO2 值相关性较差。在一个大型成人队列中,估计的菲克 CI(eFick CI)与热稀释 CI(TDCI)之间的相关性不大。我们评估了儿科队列中使用 LaFarge 估算 VO2 的 eFick CI 与 TDCI 之间的一致程度。我们对 2004 年至 2020 年期间接受心导管检查并记录有 eFick CI 和 TDCI 的 3-18 岁患者进行了回顾性单中心病历审查,其中包括 161 名患者的 201 次心导管检查。患者接受导管检查时的平均年龄为 12.2 岁(标清 4.4 岁)。最常见的诊断是心肌病,其次是先天性心脏病和肺动脉高压。在 49% 的导管检查中,TDCI 和 eFick CI 的差异大于 20%。较高的平均 CI((eFick CI + TDCI)/2)和较大的年龄可预测 eFick CI 与 TDCI 之间较大的百分比差异。平均 CI 每增加 1.0 升/分钟/平方米,CI 的预期差异百分比就会增加 9.9%(p 2 系统性地超过 TDCI)。不同方法之间的差异经常大于 20%,这可能会对临床产生重大影响。平均 CI 越高,eFick CI 与 TDCI 之间的差异就越大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Pediatric Cardiology
Pediatric Cardiology 医学-小儿科
CiteScore
3.30
自引率
6.20%
发文量
258
审稿时长
12 months
期刊介绍: The editor of Pediatric Cardiology welcomes original manuscripts concerning all aspects of heart disease in infants, children, and adolescents, including embryology and anatomy, physiology and pharmacology, biochemistry, pathology, genetics, radiology, clinical aspects, investigative cardiology, electrophysiology and echocardiography, and cardiac surgery. Articles which may include original articles, review articles, letters to the editor etc., must be written in English and must be submitted solely to Pediatric Cardiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信