A Case of Coronary Artery Perforation Caused by Manual Cardiopulmonary Resuscitation in the Catheterization Laboratory

IF 1.2 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Kei Morishita, Takatoshi Unno, Takahiko Murakami, Kensuke Okada, Hiroshi Matsunaga, Kazuo Asada, Yasutoshi Omori, Akiko Ishihara, Yoshiro Kamoi, Takahiro Tanaka
{"title":"A Case of Coronary Artery Perforation Caused by Manual Cardiopulmonary Resuscitation in the Catheterization Laboratory","authors":"Kei Morishita, Takatoshi Unno, Takahiko Murakami, Kensuke Okada, Hiroshi Matsunaga, Kazuo Asada, Yasutoshi Omori, Akiko Ishihara, Yoshiro Kamoi, Takahiro Tanaka","doi":"10.1536/ihj.23-549","DOIUrl":null,"url":null,"abstract":"</p><p>Cardiopulmonary resuscitation (CPR) is essential for the survival of cardiac arrest patients, but it can cause severe traumatic complications. In the catheterization laboratory, various physical constraints complicate the appropriate performance of CPR. However, we are not aware of reports of CPR complications in this setting. Here, we report a case of coronary artery perforation (CAP) caused by manual CPR in the catheterization laboratory. The patient, a 68-year-old woman, initially underwent successful percutaneous coronary intervention (PCI) for unstable angina. Back in the ward, the patient experienced acute stent thrombosis, which resulted in cardiac arrest, and another PCI was performed under ongoing manual CPR. Although revascularization was successful, sudden CAP occurred, leading to cardiac tamponade. Despite extensive treatment efforts, the patient died 18 hours later.</p><p>Initially, the compression site of CPR was on the midline of the sternum; however, the compression site shifted to the left, to just above the left anterior descending artery, by the time that CAP was detected via angiography. This corresponded to the area where rib fractures were observed upon computed tomography, suggesting the possibility of traumatic CAP due to manual CPR. The physical constraints in the catheterization laboratory can lead to an inappropriate CPR technique and severe traumatic complications.</p>\n<p></p>","PeriodicalId":13711,"journal":{"name":"International heart journal","volume":"7 1","pages":""},"PeriodicalIF":1.2000,"publicationDate":"2024-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International heart journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1536/ihj.23-549","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Cardiopulmonary resuscitation (CPR) is essential for the survival of cardiac arrest patients, but it can cause severe traumatic complications. In the catheterization laboratory, various physical constraints complicate the appropriate performance of CPR. However, we are not aware of reports of CPR complications in this setting. Here, we report a case of coronary artery perforation (CAP) caused by manual CPR in the catheterization laboratory. The patient, a 68-year-old woman, initially underwent successful percutaneous coronary intervention (PCI) for unstable angina. Back in the ward, the patient experienced acute stent thrombosis, which resulted in cardiac arrest, and another PCI was performed under ongoing manual CPR. Although revascularization was successful, sudden CAP occurred, leading to cardiac tamponade. Despite extensive treatment efforts, the patient died 18 hours later.

Initially, the compression site of CPR was on the midline of the sternum; however, the compression site shifted to the left, to just above the left anterior descending artery, by the time that CAP was detected via angiography. This corresponded to the area where rib fractures were observed upon computed tomography, suggesting the possibility of traumatic CAP due to manual CPR. The physical constraints in the catheterization laboratory can lead to an inappropriate CPR technique and severe traumatic complications.

导管室人工心肺复苏术导致冠状动脉穿孔一例
心肺复苏术(CPR)对心脏骤停患者的存活至关重要,但它可能导致严重的创伤并发症。在导管室,各种物理限制使心肺复苏术的适当实施变得复杂。然而,我们还没有在这种情况下进行心肺复苏并发症的报道。在此,我们报告了一例在导管室手动心肺复苏术导致的冠状动脉穿孔(CAP)病例。患者是一名 68 岁的女性,最初因不稳定型心绞痛成功接受了经皮冠状动脉介入治疗(PCI)。回到病房后,患者出现急性支架血栓,导致心脏骤停,在持续的人工心肺复苏下又进行了一次 PCI。虽然血管再通手术取得了成功,但突然发生了 CAP,导致心脏填塞。最初,心肺复苏的压迫部位位于胸骨中线;然而,在通过血管造影检测到 CAP 时,压迫部位向左移动,位于左前降支动脉上方。这与计算机断层扫描中观察到的肋骨骨折区域相对应,表明人工心肺复苏可能导致创伤性 CAP。导管室的物理限制可能会导致不恰当的心肺复苏技术和严重的创伤性并发症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
International heart journal
International heart journal 医学-心血管系统
CiteScore
2.50
自引率
6.70%
发文量
148
审稿时长
6-12 weeks
期刊介绍: Authors of research articles should disclose at the time of submission any financial arrangement they may have with a company whose product figures prominently in the submitted manuscript or with a company making a competing product. Such information will be held in confidence while the paper is under review and will not influence the editorial decision, but if the article is accepted for publication, the editors will usually discuss with the authors the manner in which such information is to be communicated to the reader.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信