Analysis After Posterior Chamber Phakic Intraocular Lens Implantation: A 17 to 19-Year Follow-up Study

Álvaro Sánchez-Ventosa, Antonio Cano-Ortiz, Timoteo González Cruces, Marta Villalba González, Alberto Membrillo, Alberto Villarrubia
{"title":"Analysis After Posterior Chamber Phakic Intraocular Lens Implantation: A 17 to 19-Year Follow-up Study","authors":"Álvaro Sánchez-Ventosa, Antonio Cano-Ortiz, Timoteo González Cruces, Marta Villalba González, Alberto Membrillo, Alberto Villarrubia","doi":"10.1097/j.jcrs.0000000000001469","DOIUrl":null,"url":null,"abstract":"Purpose: To evaluate the clinical outcomes of the Visian implantable collamer lens (ICL) in eyes with≥17 years of follow-up. Methods: Seventy eyes from 38 patients who underwent surgery between 2002-2006 with V4 ICL implantation were analyzed. Pre-intervention data included corrected distance visual acuity (CDVA), refraction, and intraocular pressure (IOP). At the 19-year mark, CDVA, refraction, IOP, endothelial count, and vault were measured using Tomey Casia 2 anterior pole tomography, along with recording long-term events. Setting: Single-center. Design: Retrospective observational study Results: The operated patients had a spherical correction between -4 and -21D and a cylinder up to 7.5D. The mean CDVA (decimal) at the 17-year check-up was 0.89±0.18, with a spherical equivalent of -1.05±1.36D. Intraocular pressure has remained stable, as mean measurements prior to surgery and currently, was 15.16 ± 2.54mmHg and 16.19 ± 3.29 mmHg respectively. The endothelial cell count showed values of 2191 ± 386 cells/mm2, with a maximum of 2804 cells and a minimum of 1125 cells. Finally, the vault obtained was 348.53 ± 234.58mm. Over the years, 2 eyes developed angle closure glaucoma, and 9 eyes were operated on for the development of anterior subcapsular cataracts. Conclusions: Visian ICL implantation demonstrated long-term visual and refractive stability, indicating it as a low-risk procedure. The ICL V4 model yielded satisfactory results for myopia and astigmatism correction after 17 years.","PeriodicalId":15233,"journal":{"name":"Journal of Cataract & Refractive Surgery","volume":"189 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-05-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cataract & Refractive Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/j.jcrs.0000000000001469","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To evaluate the clinical outcomes of the Visian implantable collamer lens (ICL) in eyes with≥17 years of follow-up. Methods: Seventy eyes from 38 patients who underwent surgery between 2002-2006 with V4 ICL implantation were analyzed. Pre-intervention data included corrected distance visual acuity (CDVA), refraction, and intraocular pressure (IOP). At the 19-year mark, CDVA, refraction, IOP, endothelial count, and vault were measured using Tomey Casia 2 anterior pole tomography, along with recording long-term events. Setting: Single-center. Design: Retrospective observational study Results: The operated patients had a spherical correction between -4 and -21D and a cylinder up to 7.5D. The mean CDVA (decimal) at the 17-year check-up was 0.89±0.18, with a spherical equivalent of -1.05±1.36D. Intraocular pressure has remained stable, as mean measurements prior to surgery and currently, was 15.16 ± 2.54mmHg and 16.19 ± 3.29 mmHg respectively. The endothelial cell count showed values of 2191 ± 386 cells/mm2, with a maximum of 2804 cells and a minimum of 1125 cells. Finally, the vault obtained was 348.53 ± 234.58mm. Over the years, 2 eyes developed angle closure glaucoma, and 9 eyes were operated on for the development of anterior subcapsular cataracts. Conclusions: Visian ICL implantation demonstrated long-term visual and refractive stability, indicating it as a low-risk procedure. The ICL V4 model yielded satisfactory results for myopia and astigmatism correction after 17 years.
后房型法康眼内透镜植入术后分析:17 至 19 年随访研究
目的:评估随访≥17 年的 Visian 可植入型有晶体眼人工晶体(ICL)的临床疗效。方法:对 2002-2006 年间接受 V4 ICL 植入手术的 38 名患者的 70 只眼睛进行分析。干预前的数据包括矫正远视力(CDVA)、屈光度和眼压(IOP)。19 年后,使用 Tomey Casia 2 前极断层扫描测量 CDVA、屈光度、眼压、内皮计数和穹窿,并记录长期事件。地点:单中心单中心。设计:回顾性观察研究回顾性观察研究 结果:手术患者的球面校正度数在-4到-21D之间,柱面校正度数达到7.5D。17 年检查时的平均 CDVA(十进制)为 0.89±0.18,球面等效度数为-1.05±1.36D。眼压保持稳定,手术前和目前的平均测量值分别为 15.16±2.54 mmHg 和 16.19±3.29 mmHg。内皮细胞计数显示值为 2191 ± 386 个细胞/平方毫米,最大值为 2804 个细胞,最小值为 1125 个细胞。最后,获得的穹隆值为 348.53 ± 234.58 毫米。多年来,有 2 只眼睛患上了闭角型青光眼,9 只眼睛因患前囊下白内障而接受了手术。结论:Visian ICL 植入术具有长期的视觉和屈光稳定性,是一种低风险手术。17 年后,ICL V4 型近视和散光矫正效果令人满意。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信