Jack S Davey, Wye Li Chong, Jake Fountain, Jane Heller, Rui Sul, Kieri Jermyn, Jacob Michelsen, Louisa Ho Eckart
{"title":"In vitro evaluation of a hybrid negative pressure system for wound therapy.","authors":"Jack S Davey, Wye Li Chong, Jake Fountain, Jane Heller, Rui Sul, Kieri Jermyn, Jacob Michelsen, Louisa Ho Eckart","doi":"10.1111/vsu.14101","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The objective of this study was to assess whether negative pressure could be maintained accurately and repeatably with a wall-suction-based hybrid negative pressure wound therapy (h-NPWT) system by comparing it with a commercial negative pressure wound therapy (NPWT) device.</p><p><strong>Study design: </strong>In vitro experimental study.</p><p><strong>Methods: </strong>A commercial NPWT device (control) and three h-NPWT devices, with 0, 3, and 6 meters of additional tubing using the hospital-wall suction (groups 1, 2, and 3 respectively), were applied sequentially to a commercial NPWT dressing on a silicone skin substrate and set to run at a continuous pressure of -125 mmHg. The pressure within the wound space was monitored at 10 second intervals for 24 h. The process was repeated five times for each group.</p><p><strong>Results: </strong>The commercial NPWT device produced an average pressure variance of 3.02 mmHg, and the h-NPWT produced average variances of 4.38, 4.24 and 4.20 mmHg for groups 1, 2 and 3, respectively. All groups produced an average pressure within 0.15 mmHg of -125 mmHg over the 24-hour period, and the h-NPWT systems produced the smallest range with all values remaining within a ±5% variation from -125 mmHg.</p><p><strong>Conclusion: </strong>The h-NPWT system achieved negative pressures that were comparable to those of a commercial control NPWT device. The addition of tubing between the skin substrate and the canister did not affect the pressure applied at the wound site.</p><p><strong>Clinical significance: </strong>The h-NPWT device tested in this study can be considered as an alternative for negative wound therapy when a commercial device cannot be used.</p>","PeriodicalId":23667,"journal":{"name":"Veterinary Surgery","volume":" ","pages":"1093-1101"},"PeriodicalIF":1.3000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary Surgery","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1111/vsu.14101","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/15 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: The objective of this study was to assess whether negative pressure could be maintained accurately and repeatably with a wall-suction-based hybrid negative pressure wound therapy (h-NPWT) system by comparing it with a commercial negative pressure wound therapy (NPWT) device.
Study design: In vitro experimental study.
Methods: A commercial NPWT device (control) and three h-NPWT devices, with 0, 3, and 6 meters of additional tubing using the hospital-wall suction (groups 1, 2, and 3 respectively), were applied sequentially to a commercial NPWT dressing on a silicone skin substrate and set to run at a continuous pressure of -125 mmHg. The pressure within the wound space was monitored at 10 second intervals for 24 h. The process was repeated five times for each group.
Results: The commercial NPWT device produced an average pressure variance of 3.02 mmHg, and the h-NPWT produced average variances of 4.38, 4.24 and 4.20 mmHg for groups 1, 2 and 3, respectively. All groups produced an average pressure within 0.15 mmHg of -125 mmHg over the 24-hour period, and the h-NPWT systems produced the smallest range with all values remaining within a ±5% variation from -125 mmHg.
Conclusion: The h-NPWT system achieved negative pressures that were comparable to those of a commercial control NPWT device. The addition of tubing between the skin substrate and the canister did not affect the pressure applied at the wound site.
Clinical significance: The h-NPWT device tested in this study can be considered as an alternative for negative wound therapy when a commercial device cannot be used.
期刊介绍:
Veterinary Surgery, the official publication of the American College of Veterinary Surgeons and European College of Veterinary Surgeons, is a source of up-to-date coverage of surgical and anesthetic management of animals, addressing significant problems in veterinary surgery with relevant case histories and observations.
It contains original, peer-reviewed articles that cover developments in veterinary surgery, and presents the most current review of the field, with timely articles on surgical techniques, diagnostic aims, care of infections, and advances in knowledge of metabolism as it affects the surgical patient. The journal places new developments in perspective, encompassing new concepts and peer commentary to help better understand and evaluate the surgical patient.