In vitro evaluation of a hybrid negative pressure system for wound therapy.

IF 1.3 2区 农林科学 Q2 VETERINARY SCIENCES
Veterinary Surgery Pub Date : 2024-08-01 Epub Date: 2024-05-15 DOI:10.1111/vsu.14101
Jack S Davey, Wye Li Chong, Jake Fountain, Jane Heller, Rui Sul, Kieri Jermyn, Jacob Michelsen, Louisa Ho Eckart
{"title":"In vitro evaluation of a hybrid negative pressure system for wound therapy.","authors":"Jack S Davey, Wye Li Chong, Jake Fountain, Jane Heller, Rui Sul, Kieri Jermyn, Jacob Michelsen, Louisa Ho Eckart","doi":"10.1111/vsu.14101","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The objective of this study was to assess whether negative pressure could be maintained accurately and repeatably with a wall-suction-based hybrid negative pressure wound therapy (h-NPWT) system by comparing it with a commercial negative pressure wound therapy (NPWT) device.</p><p><strong>Study design: </strong>In vitro experimental study.</p><p><strong>Methods: </strong>A commercial NPWT device (control) and three h-NPWT devices, with 0, 3, and 6 meters of additional tubing using the hospital-wall suction (groups 1, 2, and 3 respectively), were applied sequentially to a commercial NPWT dressing on a silicone skin substrate and set to run at a continuous pressure of -125 mmHg. The pressure within the wound space was monitored at 10 second intervals for 24 h. The process was repeated five times for each group.</p><p><strong>Results: </strong>The commercial NPWT device produced an average pressure variance of 3.02 mmHg, and the h-NPWT produced average variances of 4.38, 4.24 and 4.20 mmHg for groups 1, 2 and 3, respectively. All groups produced an average pressure within 0.15 mmHg of -125 mmHg over the 24-hour period, and the h-NPWT systems produced the smallest range with all values remaining within a ±5% variation from -125 mmHg.</p><p><strong>Conclusion: </strong>The h-NPWT system achieved negative pressures that were comparable to those of a commercial control NPWT device. The addition of tubing between the skin substrate and the canister did not affect the pressure applied at the wound site.</p><p><strong>Clinical significance: </strong>The h-NPWT device tested in this study can be considered as an alternative for negative wound therapy when a commercial device cannot be used.</p>","PeriodicalId":23667,"journal":{"name":"Veterinary Surgery","volume":" ","pages":"1093-1101"},"PeriodicalIF":1.3000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary Surgery","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1111/vsu.14101","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/15 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: The objective of this study was to assess whether negative pressure could be maintained accurately and repeatably with a wall-suction-based hybrid negative pressure wound therapy (h-NPWT) system by comparing it with a commercial negative pressure wound therapy (NPWT) device.

Study design: In vitro experimental study.

Methods: A commercial NPWT device (control) and three h-NPWT devices, with 0, 3, and 6 meters of additional tubing using the hospital-wall suction (groups 1, 2, and 3 respectively), were applied sequentially to a commercial NPWT dressing on a silicone skin substrate and set to run at a continuous pressure of -125 mmHg. The pressure within the wound space was monitored at 10 second intervals for 24 h. The process was repeated five times for each group.

Results: The commercial NPWT device produced an average pressure variance of 3.02 mmHg, and the h-NPWT produced average variances of 4.38, 4.24 and 4.20 mmHg for groups 1, 2 and 3, respectively. All groups produced an average pressure within 0.15 mmHg of -125 mmHg over the 24-hour period, and the h-NPWT systems produced the smallest range with all values remaining within a ±5% variation from -125 mmHg.

Conclusion: The h-NPWT system achieved negative pressures that were comparable to those of a commercial control NPWT device. The addition of tubing between the skin substrate and the canister did not affect the pressure applied at the wound site.

Clinical significance: The h-NPWT device tested in this study can be considered as an alternative for negative wound therapy when a commercial device cannot be used.

对用于伤口治疗的混合负压系统进行体外评估。
研究目的本研究的目的是通过与商用负压伤口治疗(NPWT)设备进行比较,评估基于墙壁吸力的混合负压伤口治疗(h-NPWT)系统能否准确、重复地维持负压:研究设计:体外实验研究:将一个商用 NPWT 设备(对照组)和三个 h-NPWT 设备(组 1、组 2 和组 3)依次应用于硅胶皮肤基底上的商用 NPWT 敷料,并设置在 -125 mmHg 的持续压力下运行。每组重复该过程五次:结果:商用 NPWT 设备产生的平均压力差异为 3.02 mmHg,而 h-NPWT 在第 1、2 和 3 组产生的平均压力差异分别为 4.38、4.24 和 4.20 mmHg。在 24 小时内,所有组的平均压力都在 -125 mmHg 的 0.15 mmHg 范围内,而 h-NPWT 系统的范围最小,所有值都与 -125 mmHg 保持在 ±5% 的变化范围内:结论:h-NPWT 系统达到的负压与商用对照 NPWT 设备相当。在皮肤基底和滤毒罐之间增加管道不会影响施加在伤口部位的压力:临床意义:本研究中测试的 h-NPWT 设备可作为无法使用商用设备时伤口负压疗法的替代方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Veterinary Surgery
Veterinary Surgery 农林科学-兽医学
CiteScore
3.40
自引率
22.20%
发文量
162
审稿时长
8-16 weeks
期刊介绍: Veterinary Surgery, the official publication of the American College of Veterinary Surgeons and European College of Veterinary Surgeons, is a source of up-to-date coverage of surgical and anesthetic management of animals, addressing significant problems in veterinary surgery with relevant case histories and observations. It contains original, peer-reviewed articles that cover developments in veterinary surgery, and presents the most current review of the field, with timely articles on surgical techniques, diagnostic aims, care of infections, and advances in knowledge of metabolism as it affects the surgical patient. The journal places new developments in perspective, encompassing new concepts and peer commentary to help better understand and evaluate the surgical patient.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信