Comparison of Dentinal Defects Induced by Rotary, Reciprocating, and Hand Files in Oval Shaped Root Canal - An In-Vitro Study.

Q3 Dentistry
Indian Journal of Dental Research Pub Date : 2023-10-01 Epub Date: 2024-04-19 DOI:10.4103/ijdr.ijdr_132_23
Harakh Chand Branawal, Neelam Mittal, Prachi Rani, Aiyman Ayubi, Silviya Samad
{"title":"Comparison of Dentinal Defects Induced by Rotary, Reciprocating, and Hand Files in Oval Shaped Root Canal - An In-Vitro Study.","authors":"Harakh Chand Branawal, Neelam Mittal, Prachi Rani, Aiyman Ayubi, Silviya Samad","doi":"10.4103/ijdr.ijdr_132_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>To evaluate and compare the formation of dentinal defects using hand Hedstrom files, XP-Shaper, TruNatomy, and Reciproc Blue file systems when used for oval shaped root canals.</p><p><strong>Materials and methods: </strong>One hundred and five extracted human mandibular premolars with single root and oval canals were selected for the study. Twenty-one teeth were unprepared (control), and the remaining teeth were divided into the prepared groups (n = 21), that is, Group H-Files, Group XP-Shaper, Group TruNatomy, and Group Reciproc Blue. All selected teeth were de-coronated perpendicular to the long axis of the tooth by using a diamond-coated disk with water cooling, leaving root segments approximately 16 mm in length. Each group was prepared according to the above file system. Then all roots were sectioned perpendicular to their long axes at 3, 6, and 9 mm from the apex using a diamond-coated disk under a continuous water stream. Each specimen was then checked for the presence of dentinal defects/microcracks.</p><p><strong>Result: </strong>The XP-Endo shaper group had the lowest number of defects (01/21 roots) 4.7%; TN (04/21) 19%, H-Files (04/21) 19%, and RC Blue (05/21) 23.8% had the highest incidence of defects. However, no significant difference was detected among these groups (P > 0.05).</p><p><strong>Conclusion: </strong>The motor-driven root canal instrumentation with rotary and reciprocating files and hand files may create microcracks in the radicular dentine, whereas the XP-Shaper file system produces minimal or less cracks compared to other tested rotary file systems and H-file instrumentation.</p>","PeriodicalId":13311,"journal":{"name":"Indian Journal of Dental Research","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Dental Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ijdr.ijdr_132_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/4/19 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: To evaluate and compare the formation of dentinal defects using hand Hedstrom files, XP-Shaper, TruNatomy, and Reciproc Blue file systems when used for oval shaped root canals.

Materials and methods: One hundred and five extracted human mandibular premolars with single root and oval canals were selected for the study. Twenty-one teeth were unprepared (control), and the remaining teeth were divided into the prepared groups (n = 21), that is, Group H-Files, Group XP-Shaper, Group TruNatomy, and Group Reciproc Blue. All selected teeth were de-coronated perpendicular to the long axis of the tooth by using a diamond-coated disk with water cooling, leaving root segments approximately 16 mm in length. Each group was prepared according to the above file system. Then all roots were sectioned perpendicular to their long axes at 3, 6, and 9 mm from the apex using a diamond-coated disk under a continuous water stream. Each specimen was then checked for the presence of dentinal defects/microcracks.

Result: The XP-Endo shaper group had the lowest number of defects (01/21 roots) 4.7%; TN (04/21) 19%, H-Files (04/21) 19%, and RC Blue (05/21) 23.8% had the highest incidence of defects. However, no significant difference was detected among these groups (P > 0.05).

Conclusion: The motor-driven root canal instrumentation with rotary and reciprocating files and hand files may create microcracks in the radicular dentine, whereas the XP-Shaper file system produces minimal or less cracks compared to other tested rotary file systems and H-file instrumentation.

椭圆形根管中旋转式、往复式和手动锉造成的牙本质缺陷比较 - 体外研究
目的:评估和比较使用手工Hedstrom锉、XP-Shaper锉、TruNatomy锉和Reciproc Blue锉系统治疗椭圆形根管时牙本质缺损的形成情况:研究选择了 15 颗单根椭圆形根管的人类下颌前磨牙。其中 21 颗牙齿未经预备(对照组),其余牙齿分为预备组(n = 21),即 H 型锉组、XP-Shaper 组、TruNatomy 组和 Reciproc Blue 组。所有被选中的牙齿都在垂直于牙齿长轴的方向上使用带钻石涂层的圆盘进行去冠,并进行水冷,留下长度约为 16 毫米的根段。每组都按照上述文件系统进行准备。然后,在连续水流下使用金刚石涂层圆盘,在距顶点 3、6 和 9 毫米处对所有牙根进行垂直于长轴的切片。然后检查每个样本是否存在牙本质缺陷/微裂纹:XP-Endo修整器组的缺损数量最少(01/21根),为4.7%;TN组(04/21根)为19%,H-Files组(04/21根)为19%,RC Blue组(05/21根)为23.8%,缺损发生率最高。然而,这些组别之间没有发现明显差异(P>0.05):结论:使用旋转锉、往复锉和手动锉的电机驱动根管器械可能会在根尖牙本质中产生微裂缝,而与其他测试过的旋转锉系统和H锉器械相比,XP-Shaper锉系统产生的裂缝最小或更少。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Indian Journal of Dental Research
Indian Journal of Dental Research Dentistry-Dentistry (all)
CiteScore
1.80
自引率
0.00%
发文量
80
审稿时长
38 weeks
期刊介绍: Indian Journal of Dental Research (IJDR) is the official publication of the Indian Society for Dental Research (ISDR), India section of the International Association for Dental Research (IADR), published quarterly. IJDR publishes scientific papers on well designed and controlled original research involving orodental sciences. Papers may also include reports on unusual and interesting case presentations and invited review papers on significant topics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信