{"title":"Five-Year Transcatheter Aortic Valve Replacement Outcomes in Chronic Hemodialysis vs. Non-Hemodialysis Patients Using Balloon-Expandable Devices.","authors":"Isamu Mizote, Daisuke Nakamura, Koichi Maeda, Tomoharu Dohi, Kazuo Shimamura, Ai Kawamura, Kizuku Yamashita, Yutaka Matsuhiro, Shumpei Kosugi, Hiroki Sugae, Yasuharu Takeda, Yasushi Sakata","doi":"10.1253/circj.CJ-24-0050","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Based on the results of a clinical trial in Japan, transcatheter aortic valve replacement (TAVR) for hemodialysis (HD) patients gained approval; however, mid-term TAVR outcomes and transcatheter aortic valve (TAV) durability in HD patients remain unexplored.</p><p><strong>Methods and results: </strong>We analyzed background, procedural, in-hospital outcome, and follow-up data for 101 HD patients and 494 non-HD patients who underwent TAVR using balloon-expandable valves (SAPIEN XT or SAPIEN 3) retrieved from Osaka University Hospital TAVR database. Periprocedural mortality and TAVR-related complications were comparable between HD and non-HD patients. However, Kaplan-Meier analysis revealed that HD patients had significantly lower survival rates (log-rank test, P<0.001). In addition, HD patients had significantly higher rates of severe structural valve deterioration (SVD) than non-HD patients (Gray test, P=0.038).</p><p><strong>Conclusions: </strong>TAVR in HD patients had comparable periprocedural mortality but inferior mid-term survival and TAV durability than in non-HD patients. Indications for TAVR in younger HD patients should be carefully determined, considering the possibility of a TAV-in-TAV procedure when early SVD occurs.</p>","PeriodicalId":50691,"journal":{"name":"Circulation Journal","volume":" ","pages":"1937-1945"},"PeriodicalIF":3.1000,"publicationDate":"2024-11-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Circulation Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1253/circj.CJ-24-0050","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/11 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Based on the results of a clinical trial in Japan, transcatheter aortic valve replacement (TAVR) for hemodialysis (HD) patients gained approval; however, mid-term TAVR outcomes and transcatheter aortic valve (TAV) durability in HD patients remain unexplored.
Methods and results: We analyzed background, procedural, in-hospital outcome, and follow-up data for 101 HD patients and 494 non-HD patients who underwent TAVR using balloon-expandable valves (SAPIEN XT or SAPIEN 3) retrieved from Osaka University Hospital TAVR database. Periprocedural mortality and TAVR-related complications were comparable between HD and non-HD patients. However, Kaplan-Meier analysis revealed that HD patients had significantly lower survival rates (log-rank test, P<0.001). In addition, HD patients had significantly higher rates of severe structural valve deterioration (SVD) than non-HD patients (Gray test, P=0.038).
Conclusions: TAVR in HD patients had comparable periprocedural mortality but inferior mid-term survival and TAV durability than in non-HD patients. Indications for TAVR in younger HD patients should be carefully determined, considering the possibility of a TAV-in-TAV procedure when early SVD occurs.
期刊介绍:
Circulation publishes original research manuscripts, review articles, and other content related to cardiovascular health and disease, including observational studies, clinical trials, epidemiology, health services and outcomes studies, and advances in basic and translational research.