Simultaneous sensing of carbidopa and levodopa by a novel strategy based on dual-emission ratiometric assay of modified carbon dots

IF 3.2 4区 生物学 Q2 BIOCHEMISTRY & MOLECULAR BIOLOGY
Sasan Abbasi Majd, Soheila Kashanian, Zahra Shekarbeygi, Mahsa Babaei
{"title":"Simultaneous sensing of carbidopa and levodopa by a novel strategy based on dual-emission ratiometric assay of modified carbon dots","authors":"Sasan Abbasi Majd,&nbsp;Soheila Kashanian,&nbsp;Zahra Shekarbeygi,&nbsp;Mahsa Babaei","doi":"10.1002/bab.2595","DOIUrl":null,"url":null,"abstract":"<p>Rapid control of the content of Parkinson's drugs in biological fluids and pharmaceutical formulations is of great importance because changes in the concentration of these drugs affect their bioavailability and biopharmaceutical properties. Therefore, we presented a simple and convenient method for the ratiometric detection of carbidopa and levodopa for carbon dots (CDs) dual-fluorescent emission. Dual-emission CDs were prepared from chitosan using a microwave method, following which the surface was chemically modified with terephthalaldehyde. CDs had two strong well-separated peaks at 445 and 510 nm. The relative measurement of carbidopa and levodopa was based on the static extinction of CDs at 445 nm and increase at 510 nm, respectively. The linear range for carbidopa measurement was 2.5–300 nM, with a limit of detection (LOD) of 2.1 nM, and a relative standard deviation (RSD) of 1.68%. Further, the linear range for levodopa measurement was equal to 3.0–400 nM, with LOD and RSD% of 2.8 nM and 3.5%, respectively. Also, selectivity of ratiometric sensor in the presence of interferences was investigated, which showed that the recovery of carbidopa and levodopa in serum and urine samples has changed between 96.80% and 116.24% with RSD% 0.11–0.77. CDs also provided good results for the determination of carbidopa and levodopa in real samples, and had high selectivity in the presence of possible interferences.</p>","PeriodicalId":9274,"journal":{"name":"Biotechnology and applied biochemistry","volume":"71 5","pages":"1032-1043"},"PeriodicalIF":3.2000,"publicationDate":"2024-05-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biotechnology and applied biochemistry","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/bab.2595","RegionNum":4,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMISTRY & MOLECULAR BIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Rapid control of the content of Parkinson's drugs in biological fluids and pharmaceutical formulations is of great importance because changes in the concentration of these drugs affect their bioavailability and biopharmaceutical properties. Therefore, we presented a simple and convenient method for the ratiometric detection of carbidopa and levodopa for carbon dots (CDs) dual-fluorescent emission. Dual-emission CDs were prepared from chitosan using a microwave method, following which the surface was chemically modified with terephthalaldehyde. CDs had two strong well-separated peaks at 445 and 510 nm. The relative measurement of carbidopa and levodopa was based on the static extinction of CDs at 445 nm and increase at 510 nm, respectively. The linear range for carbidopa measurement was 2.5–300 nM, with a limit of detection (LOD) of 2.1 nM, and a relative standard deviation (RSD) of 1.68%. Further, the linear range for levodopa measurement was equal to 3.0–400 nM, with LOD and RSD% of 2.8 nM and 3.5%, respectively. Also, selectivity of ratiometric sensor in the presence of interferences was investigated, which showed that the recovery of carbidopa and levodopa in serum and urine samples has changed between 96.80% and 116.24% with RSD% 0.11–0.77. CDs also provided good results for the determination of carbidopa and levodopa in real samples, and had high selectivity in the presence of possible interferences.

基于改性碳点双发射比率测定法的新策略同时检测卡比多巴和左旋多巴
快速控制生物液体和药物制剂中帕金森氏症药物的含量非常重要,因为这些药物浓度的变化会影响其生物利用度和生物制药特性。因此,我们提出了一种简单方便的方法,利用碳点(CD)双荧光发射对卡比多巴和左旋多巴进行比率检测。双发射 CD 由壳聚糖通过微波法制备而成,然后用对苯二甲醛对其表面进行化学修饰。CD 在 445 纳米和 510 纳米波长处有两个强弱分明的峰值。卡比多巴和左旋多巴的相对测量分别基于 CD 在 445 纳米波长处的静态消光和在 510 纳米波长处的增加。卡比多巴的线性范围为 2.5-300 nM,检出限(LOD)为 2.1 nM,相对标准偏差(RSD)为 1.68%。此外,左旋多巴测量的线性范围为 3.0-400 nM,检出限和相对标准偏差分别为 2.8 nM 和 3.5%。此外,还研究了存在干扰时比率传感器的选择性,结果表明血清和尿液样品中卡比多巴和左旋多巴的回收率在 96.80% 和 116.24% 之间变化,RSD% 为 0.11-0.77。CD 还为实际样品中卡比多巴和左旋多巴的测定提供了良好的结果,并且在可能存在干扰的情况下具有较高的选择性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Biotechnology and applied biochemistry
Biotechnology and applied biochemistry 工程技术-生化与分子生物学
CiteScore
6.00
自引率
7.10%
发文量
117
审稿时长
3 months
期刊介绍: Published since 1979, Biotechnology and Applied Biochemistry is dedicated to the rapid publication of high quality, significant research at the interface between life sciences and their technological exploitation. The Editors will consider papers for publication based on their novelty and impact as well as their contribution to the advancement of medical biotechnology and industrial biotechnology, covering cutting-edge research in synthetic biology, systems biology, metabolic engineering, bioengineering, biomaterials, biosensing, and nano-biotechnology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信