Development and Validation of a Simple High-Pressure Liquid Chromatography-Ultraviolet Detection Method for Simultaneous Quantitation of First-Line Anti-Tuberculosis Drugs in Formulations of Fixed-Dose Combination.
{"title":"Development and Validation of a Simple High-Pressure Liquid Chromatography-Ultraviolet Detection Method for Simultaneous Quantitation of First-Line Anti-Tuberculosis Drugs in Formulations of Fixed-Dose Combination.","authors":"Sudha Vilvamani, Santhanamahalingam Mahalingam, Sruthi Nhavilthodi, Dharman Murugesan, Shanmugam Murugaiha Jeyakumar","doi":"10.1093/chromsci/bmae023","DOIUrl":null,"url":null,"abstract":"<p><p>The current treatment protocol for drug-sensitive tuberculosis involves all four first-line anti-tuberculosis drugs: rifampicin, isoniazid, pyrazinamide and ethambutol hydrochloride in a single tablet, known as fixed-dose combination tablets. However, the analytical methods are scanty to test all these drugs simultaneously in a single run without any pre-sample process or using a simple method suitable for resource-limited settings. In this method, 50 mM potassium phosphate buffer containing 0.2% triethylamine (without pH adjustment) added with acetonitrile (98:2, v/v) was served as mobile phase A, while mobile phase B was 100% acetonitrile. All four drugs were separated within 10.3 min using a gradient mobile phase program in a C18 column (150 mm × 4.6 mm; 5 μm) and detected at two ultraviolet wavelengths (238 nm for rifampicin, isoniazid and pyrazinamide, and 210 nm for ethambutol hydrochloride). The method was selective, sensitive and linear with a correlation coefficient >0.999 with the acceptable precision and accuracy (<2% relative standard deviation) for all four drugs. In conclusion, the method is simple and it does not require any pH adjustment of the buffer/mobile phase, and within 11 min, the separation of all four drugs can be achieved. Overall, the method is suitable for quality testing of fixed-dose combination tablets in limited-resource settings.</p>","PeriodicalId":15430,"journal":{"name":"Journal of chromatographic science","volume":" ","pages":"821-828"},"PeriodicalIF":1.5000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of chromatographic science","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1093/chromsci/bmae023","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
The current treatment protocol for drug-sensitive tuberculosis involves all four first-line anti-tuberculosis drugs: rifampicin, isoniazid, pyrazinamide and ethambutol hydrochloride in a single tablet, known as fixed-dose combination tablets. However, the analytical methods are scanty to test all these drugs simultaneously in a single run without any pre-sample process or using a simple method suitable for resource-limited settings. In this method, 50 mM potassium phosphate buffer containing 0.2% triethylamine (without pH adjustment) added with acetonitrile (98:2, v/v) was served as mobile phase A, while mobile phase B was 100% acetonitrile. All four drugs were separated within 10.3 min using a gradient mobile phase program in a C18 column (150 mm × 4.6 mm; 5 μm) and detected at two ultraviolet wavelengths (238 nm for rifampicin, isoniazid and pyrazinamide, and 210 nm for ethambutol hydrochloride). The method was selective, sensitive and linear with a correlation coefficient >0.999 with the acceptable precision and accuracy (<2% relative standard deviation) for all four drugs. In conclusion, the method is simple and it does not require any pH adjustment of the buffer/mobile phase, and within 11 min, the separation of all four drugs can be achieved. Overall, the method is suitable for quality testing of fixed-dose combination tablets in limited-resource settings.
期刊介绍:
The Journal of Chromatographic Science is devoted to the dissemination of information concerning all methods of chromatographic analysis. The standard manuscript is a description of recent original research that covers any or all phases of a specific separation problem, principle, or method. Manuscripts which have a high degree of novelty and fundamental significance to the field of separation science are particularly encouraged. It is expected the authors will clearly state in the Introduction how their method compares in some markedly new and improved way to previous published related methods. Analytical performance characteristics of new methods including sensitivity, tested limits of detection or quantification, accuracy, precision, and specificity should be provided. Manuscripts which describe a straightforward extension of a known analytical method or an application to a previously analyzed and/or uncomplicated sample matrix will not normally be reviewed favorably. Manuscripts in which mass spectrometry is the dominant analytical method and chromatography is of marked secondary importance may be declined.