Endothelial dysfunction in breast cancer survivors on aromatase inhibitors: changes over time.

IF 3.2 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Adnan Shaaban, Ashley Petersen, Heather Beckwith, Natalia Florea, David A Potter, Douglas Yee, Rachel I Vogel, Daniel Duprez, Anne H Blaes
{"title":"Endothelial dysfunction in breast cancer survivors on aromatase inhibitors: changes over time.","authors":"Adnan Shaaban, Ashley Petersen, Heather Beckwith, Natalia Florea, David A Potter, Douglas Yee, Rachel I Vogel, Daniel Duprez, Anne H Blaes","doi":"10.1186/s40959-024-00227-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Breast cancer is estimated to comprise about 290,560 new cases in 2022. Aromatase inhibitors (AIs) are recommended as adjuvant treatment for estrogen-receptor positive (ER+) breast carcinoma in postmenopausal women, which includes approximately two-thirds of all women with breast cancer. AIs inhibit the peripheral conversion of androgens to estrogen by deactivation of the aromatase enzyme, leading to a reduction in serum estrogen level in postmenopausal women with ER+ breast carcinoma. Estrogen is known for its cardiovascular (CV) protective properties through a variety of mechanisms including vasodilation of blood vessels and inhibition of vascular injury resulting in the prevention of atherosclerosis. In clinical trials and prospective cohorts, the long-term use of AIs can increase the risk for hypertension and hyperlipidemia. Studies demonstrate mixed results as to the impact of AIs on actual CV events and overall survival.</p><p><strong>Methods: </strong>A single arm longitudinal study of 14 postmenopausal women with ER+ breast cancer prescribed adjuvant AIs at the University of Minnesota (UMN). Subjects with a history of known tobacco use, hypertension, hyperlipidemia, and diabetes were excluded to eliminate potential confounding factors. Participants underwent routine labs, blood pressure assessments, and vascular testing at baseline (prior to starting AIs) and at six months. Vascular assessment was performed using the EndoPAT 2000 and HDI/PulseWave CR-2000 Cardiovascular Profiling System and pulse contour analysis on two occasions as previously described. Vascular measurements were conducted by one trained vascular technician. Assessments were performed in triplicate, and the mean indices were used for analyses. All subjects were on an AI at the follow-up visit. The protocol was approved by the UMN Institutional Review Board and all participants were provided written informed consent. Baseline and follow-up characteristics were compared using Wilcoxon signed-rank tests. Analyses were performed using R version 3.6.1 (R Foundation for Statistical Computing, Vienna, Austria).</p><p><strong>Results: </strong>After six months of AI treatment, EndoPAT® ratio declined to a median 1.12 (Q1: 0.85, Q3: 1.86; p = 0.045; Figure 1) and median estradiol levels decreased to 2 pg/mL (Q1: 2, Q3: 3; p=0.052). There was no evidence of association between change in EndoPAT® and change in estradiol level (p = 0.91). There were no statistically significant changes in small or large arterial elasticity.</p><p><strong>Conclusions: </strong>We hypothesize that long-term use of AI can lead to persistent endothelial dysfunction, and further investigation is necessary. In our study, patients were on AI for approximately 5-10 years. As a result, we do not have data on whether these changes, such as EndoPAT® ratio and the elasticity of small and large arterial, are reversible with discontinuation of AI. These findings set the stage for a larger study to more conclusively determine the association between AI exposure and cardiovascular outcomes. Further studies should evaluate for multivariate associations withmodifiable risk factors for CV disease.</p>","PeriodicalId":9804,"journal":{"name":"Cardio-oncology","volume":null,"pages":null},"PeriodicalIF":3.2000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11062002/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardio-oncology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s40959-024-00227-z","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Breast cancer is estimated to comprise about 290,560 new cases in 2022. Aromatase inhibitors (AIs) are recommended as adjuvant treatment for estrogen-receptor positive (ER+) breast carcinoma in postmenopausal women, which includes approximately two-thirds of all women with breast cancer. AIs inhibit the peripheral conversion of androgens to estrogen by deactivation of the aromatase enzyme, leading to a reduction in serum estrogen level in postmenopausal women with ER+ breast carcinoma. Estrogen is known for its cardiovascular (CV) protective properties through a variety of mechanisms including vasodilation of blood vessels and inhibition of vascular injury resulting in the prevention of atherosclerosis. In clinical trials and prospective cohorts, the long-term use of AIs can increase the risk for hypertension and hyperlipidemia. Studies demonstrate mixed results as to the impact of AIs on actual CV events and overall survival.

Methods: A single arm longitudinal study of 14 postmenopausal women with ER+ breast cancer prescribed adjuvant AIs at the University of Minnesota (UMN). Subjects with a history of known tobacco use, hypertension, hyperlipidemia, and diabetes were excluded to eliminate potential confounding factors. Participants underwent routine labs, blood pressure assessments, and vascular testing at baseline (prior to starting AIs) and at six months. Vascular assessment was performed using the EndoPAT 2000 and HDI/PulseWave CR-2000 Cardiovascular Profiling System and pulse contour analysis on two occasions as previously described. Vascular measurements were conducted by one trained vascular technician. Assessments were performed in triplicate, and the mean indices were used for analyses. All subjects were on an AI at the follow-up visit. The protocol was approved by the UMN Institutional Review Board and all participants were provided written informed consent. Baseline and follow-up characteristics were compared using Wilcoxon signed-rank tests. Analyses were performed using R version 3.6.1 (R Foundation for Statistical Computing, Vienna, Austria).

Results: After six months of AI treatment, EndoPAT® ratio declined to a median 1.12 (Q1: 0.85, Q3: 1.86; p = 0.045; Figure 1) and median estradiol levels decreased to 2 pg/mL (Q1: 2, Q3: 3; p=0.052). There was no evidence of association between change in EndoPAT® and change in estradiol level (p = 0.91). There were no statistically significant changes in small or large arterial elasticity.

Conclusions: We hypothesize that long-term use of AI can lead to persistent endothelial dysfunction, and further investigation is necessary. In our study, patients were on AI for approximately 5-10 years. As a result, we do not have data on whether these changes, such as EndoPAT® ratio and the elasticity of small and large arterial, are reversible with discontinuation of AI. These findings set the stage for a larger study to more conclusively determine the association between AI exposure and cardiovascular outcomes. Further studies should evaluate for multivariate associations withmodifiable risk factors for CV disease.

使用芳香化酶抑制剂的乳腺癌幸存者的内皮功能障碍:随时间的变化。
背景:据估计,2022 年新增乳腺癌病例约为 290,560 例。芳香化酶抑制剂(AIs)被推荐作为绝经后妇女雌激素受体阳性(ER+)乳腺癌的辅助治疗药物,绝经后妇女约占乳腺癌患者总数的三分之二。雌激素受体抑制剂通过使芳香化酶失活来抑制雄激素向雌激素的外周转化,从而降低患有ER+乳腺癌的绝经后妇女的血清雌激素水平。众所周知,雌激素通过多种机制具有保护心血管(CV)的作用,包括扩张血管和抑制血管损伤,从而预防动脉粥样硬化。在临床试验和前瞻性队列中,长期使用人工合成雌激素会增加高血压和高脂血症的风险。关于人工合成药物对实际心血管事件和总生存期的影响,研究结果不一:方法:明尼苏达大学(UMN)对 14 名患有 ER+ 乳腺癌的绝经后妇女进行了单臂纵向研究。为消除潜在的混杂因素,排除了已知有吸烟史、高血压、高脂血症和糖尿病的受试者。受试者在基线(开始使用人工合成药物之前)和六个月时接受了常规化验、血压评估和血管检测。血管评估是使用 EndoPAT 2000 和 HDI/PulseWave CR-2000 心血管轮廓分析系统以及脉搏轮廓分析进行的,具体方法如前所述。血管测量由一名训练有素的血管技师进行。评估一式三份,平均指数用于分析。所有受试者在随访时都服用了 AI。该方案获得了 UMN 机构审查委员会的批准,所有受试者都获得了书面知情同意。使用 Wilcoxon 符号秩检验比较基线和随访特征。分析使用 R 3.6.1 版(奥地利维也纳 R 统计计算基金会)进行:经过 6 个月的人工授精治疗后,EndoPAT® 比率下降到中位数 1.12(第一季度:0.85,第三季度:1.86;p=0.045;图 1),雌二醇水平中位数下降到 2 pg/mL(第一季度:2,第三季度:3;p=0.052)。没有证据表明 EndoPAT® 的变化与雌二醇水平的变化有关(p = 0.91)。小动脉和大动脉弹性的变化没有统计学意义:我们推测,长期服用 AI 可导致持续性内皮功能障碍,因此有必要进行进一步研究。在我们的研究中,患者服用人工血管生成素的时间约为 5-10 年。因此,我们没有数据说明这些变化(如 EndoPAT® 比率和大小动脉弹性)是否会随着停用 AI 而逆转。这些研究结果为开展更大规模的研究奠定了基础,以便更确凿地确定 AI 暴露与心血管后果之间的关联。进一步的研究应评估与心血管疾病可调节风险因素之间的多变量关联。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Cardio-oncology
Cardio-oncology Medicine-Cardiology and Cardiovascular Medicine
CiteScore
5.00
自引率
3.00%
发文量
17
审稿时长
7 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信