Evaluation of different body temperature measurement methods for patients in the intraoperative period.

IF 1.5 4区 医学 Q3 NURSING
Revista Latino-Americana De Enfermagem Pub Date : 2024-04-12 eCollection Date: 2024-01-01 DOI:10.1590/1518-8345.6873.4143
Ariane Souza do Nascimento, Cassiane de Santana Lemos, Fernanda Baratojo Biachi, Fernanda Ribeiro Silva de Lyra, Juliana Rizzo Gnatta, Vanessa de Brito Poveda
{"title":"Evaluation of different body temperature measurement methods for patients in the intraoperative period.","authors":"Ariane Souza do Nascimento, Cassiane de Santana Lemos, Fernanda Baratojo Biachi, Fernanda Ribeiro Silva de Lyra, Juliana Rizzo Gnatta, Vanessa de Brito Poveda","doi":"10.1590/1518-8345.6873.4143","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>this study aimed at estimating and comparing the reliability of temperature measurements obtained using a peripheral infrared temporal thermometer, a central cutaneous thermometer (\"Zero-Heat-Flux Cutaneous thermometer\") and an esophageal or nasopharyngeal thermometer among elective surgical patients in the intraoperative period.</p><p><strong>Method: </strong>a longitudinal study with repeated measures carried out by convenience sampling of 99 patients, aged at least 18 years old, undergoing elective abdominal cancer surgeries, with anesthesia lasting at least one hour, with each patient having their temperature measured by all three methods.</p><p><strong>Results: </strong>the intraclass correlation coefficient showed a low correlation between the measurements using the peripheral temporal thermometer and the central cutaneous (0.0324) and esophageal/nasopharyngeal (-0.138) thermometers. There was a high correlation (0.744) between the central thermometers evaluated.</p><p><strong>Conclusion: </strong>the data from the current study do not recommend using infrared temporal thermometers as a strategy for measuring the body temperature of patients undergoing anesthetic-surgical procedures. Central cutaneous thermometers and esophageal/nasopharyngeal thermometers are equivalent for detecting intraoperative hypothermia.</p>","PeriodicalId":48692,"journal":{"name":"Revista Latino-Americana De Enfermagem","volume":"32 ","pages":"e4143"},"PeriodicalIF":1.5000,"publicationDate":"2024-04-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Latino-Americana De Enfermagem","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1590/1518-8345.6873.4143","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"NURSING","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: this study aimed at estimating and comparing the reliability of temperature measurements obtained using a peripheral infrared temporal thermometer, a central cutaneous thermometer ("Zero-Heat-Flux Cutaneous thermometer") and an esophageal or nasopharyngeal thermometer among elective surgical patients in the intraoperative period.

Method: a longitudinal study with repeated measures carried out by convenience sampling of 99 patients, aged at least 18 years old, undergoing elective abdominal cancer surgeries, with anesthesia lasting at least one hour, with each patient having their temperature measured by all three methods.

Results: the intraclass correlation coefficient showed a low correlation between the measurements using the peripheral temporal thermometer and the central cutaneous (0.0324) and esophageal/nasopharyngeal (-0.138) thermometers. There was a high correlation (0.744) between the central thermometers evaluated.

Conclusion: the data from the current study do not recommend using infrared temporal thermometers as a strategy for measuring the body temperature of patients undergoing anesthetic-surgical procedures. Central cutaneous thermometers and esophageal/nasopharyngeal thermometers are equivalent for detecting intraoperative hypothermia.

对术中患者不同体温测量方法的评估。
目的:本研究旨在估计和比较择期手术患者在术中使用外周红外颞温计、中心皮肤温度计("零热流皮肤温度计")和食道或鼻咽温度计测量体温的可靠性。结果:类内相关系数显示,使用外周颞部温度计和中央皮肤温度计(0.0324)及食道/鼻咽温度计(-0.138)测量的体温之间的相关性较低。结论:本研究的数据不建议使用红外颞温计作为测量麻醉手术患者体温的策略。中心皮肤温度计和食道/鼻咽温度计在检测术中体温过低方面效果相当。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
11.10%
发文量
142
期刊介绍: A Revista Latino-Americana de Enfermagem constitui-se no órgão oficial de divulgação científica da Escola de Enfermagem de Ribeirão Preto da Universidade de São Paulo e do Centro Colaborador da OMS para o Desenvolvimento da Pesquisa em Enfermagem. Foi criada em abril de 1992 sendo sua primeira edição publicada em janeiro de 1993. No período de 1993 a 1997 tinha periodicidade semestral, de 1997 a 2000 trimestral e, a partir de janeiro de 2001, tem periodicidade bimestral. Caracteriza-se como periódico de circulação internacional, abrangendo predominantemente os países da América Latina e Caribe, embora seja também divulgado para assinantes dos Estados Unidos, Portugal e Espanha.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信