{"title":"Analysis of flow cytometry data from ultrasound-guided lymph node biopsies with two types of needles","authors":"Xin Jin, Huifang Jiang, Yuxia Jiang, Zhilu Chen, Wenfei Zhou, Qing Pan, Shuyuan Tian","doi":"10.1111/ijlh.14306","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>In this study, we combined two techniques, ultrasound-guided needle biopsy and flow cytometry (FCM), to explore their value in patients with enlarged lymph nodes.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>We compared the results of 198 needle biopsies on FCM and pathology. Forty-two were done by (fine needle aspiration, FNA), and the remaining 156 with (core needle biopsy, CNB), in 36 of 156 patients, a FNA was performed in the same lymph node after completion of the CNB. Except for five types of pathological entities, the rest were differentiated only detected or undetected tumours as the outcome distinction.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Among the 198 needle biopsies, 13 were inadequate specimens, while the remaining 185 had pathological findings, including 47 benign and 138 neoplastic findings. Thirty-six patients underwent puncture with both FNA and CNB, both needles produced identical results by FCM, but more cells were obtained by FNA. Among the pathologically positive results, there were 23 missed diagnoses in FCM, in contrast, evidence of tumours was observed in the FCM images of 15 needle biopsies that reported benign or findings that were inconsistent with pathology, and the final diagnosis was consistent with the FCM in 10 cases. FCM detected haematolymphoid tumours with a sensitivity of 87.8% and a specificity of 91.9%.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>The combination of FCM and ultrasound-guided lymph node needle biopsy can quickly provide guidance for clinical decision-making. We recommend that all lymph node needle biopsies be sent for FCM, the specimen can be obtained by the last puncture with FNA.</p>\n </section>\n </div>","PeriodicalId":14120,"journal":{"name":"International Journal of Laboratory Hematology","volume":"46 5","pages":"869-877"},"PeriodicalIF":2.2000,"publicationDate":"2024-05-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Laboratory Hematology","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/ijlh.14306","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background
In this study, we combined two techniques, ultrasound-guided needle biopsy and flow cytometry (FCM), to explore their value in patients with enlarged lymph nodes.
Methods
We compared the results of 198 needle biopsies on FCM and pathology. Forty-two were done by (fine needle aspiration, FNA), and the remaining 156 with (core needle biopsy, CNB), in 36 of 156 patients, a FNA was performed in the same lymph node after completion of the CNB. Except for five types of pathological entities, the rest were differentiated only detected or undetected tumours as the outcome distinction.
Results
Among the 198 needle biopsies, 13 were inadequate specimens, while the remaining 185 had pathological findings, including 47 benign and 138 neoplastic findings. Thirty-six patients underwent puncture with both FNA and CNB, both needles produced identical results by FCM, but more cells were obtained by FNA. Among the pathologically positive results, there were 23 missed diagnoses in FCM, in contrast, evidence of tumours was observed in the FCM images of 15 needle biopsies that reported benign or findings that were inconsistent with pathology, and the final diagnosis was consistent with the FCM in 10 cases. FCM detected haematolymphoid tumours with a sensitivity of 87.8% and a specificity of 91.9%.
Conclusion
The combination of FCM and ultrasound-guided lymph node needle biopsy can quickly provide guidance for clinical decision-making. We recommend that all lymph node needle biopsies be sent for FCM, the specimen can be obtained by the last puncture with FNA.
期刊介绍:
The International Journal of Laboratory Hematology provides a forum for the communication of new developments, research topics and the practice of laboratory haematology.
The journal publishes invited reviews, full length original articles, and correspondence.
The International Journal of Laboratory Hematology is the official journal of the International Society for Laboratory Hematology, which addresses the following sub-disciplines: cellular analysis, flow cytometry, haemostasis and thrombosis, molecular diagnostics, haematology informatics, haemoglobinopathies, point of care testing, standards and guidelines.
The journal was launched in 2006 as the successor to Clinical and Laboratory Hematology, which was first published in 1979. An active and positive editorial policy ensures that work of a high scientific standard is reported, in order to bridge the gap between practical and academic aspects of laboratory haematology.