Evaluation of early bacterial adhesion on CAD/CAM dental materials: an in situ study.

IF 1.9 3区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Odontology Pub Date : 2025-01-01 Epub Date: 2024-05-05 DOI:10.1007/s10266-024-00944-y
Stefan Vulović, Aleksandar Todorović, Boško Toljić, Nataša Nikolić-Jakoba, Tamara Vlajić Tovilović, Aleksandra Milić-Lemić
{"title":"Evaluation of early bacterial adhesion on CAD/CAM dental materials: an in situ study.","authors":"Stefan Vulović, Aleksandar Todorović, Boško Toljić, Nataša Nikolić-Jakoba, Tamara Vlajić Tovilović, Aleksandra Milić-Lemić","doi":"10.1007/s10266-024-00944-y","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this research was to determine if there are differences in early bacterial adhesion among CAD/CAM dental materials after 24 h exposure in the oral environment. One hundred twenty specimens were prepared according to the manufacturer's recommendations and divided into six groups: RBC (resin-based composite), PMMA (polymethyl methacrylate), PEEK (polyether ether ketone), ZP (zirconia polished), ZG (zirconia glazed), and cobalt-chromium alloy (CoCr alloy). Twenty healthy participants were instructed to carry an intraoral device with six specimens, one per group, for 24 h. Thereafter, real-time polymerase chain reaction (qPCR) and scanning electron microscopy (SEM) analyses enabled quantification and 2D view of biofilm formed on the specimens' surfaces. Kruskal-Wallis test and Dunn's post hoc analysis were used for inter-group comparison and data were presented as median (minimum-maximum). RBC specimens accumulated less bacteria, in comparison with ZG (p = 0.017) and PEEK specimens (p = 0.030), that dominated with the highest amount of adhered bacterial biofilm. PMMA, CoCr, and ZP specimens adhered more bacteria than RBC (p > 0.05), and less than ZG (p > 0.05) and PEEK (p > 0.05). The bacterial number varied considerably among participants. The obtained results enable a closer view into the susceptibility of CAD/CAM materials to microorganisms during the presence in the oral environment, which can be beneficial for a proper selection of these materials for a variety of dental restorations.</p>","PeriodicalId":19390,"journal":{"name":"Odontology","volume":" ","pages":"101-110"},"PeriodicalIF":1.9000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Odontology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10266-024-00944-y","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/5 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

The aim of this research was to determine if there are differences in early bacterial adhesion among CAD/CAM dental materials after 24 h exposure in the oral environment. One hundred twenty specimens were prepared according to the manufacturer's recommendations and divided into six groups: RBC (resin-based composite), PMMA (polymethyl methacrylate), PEEK (polyether ether ketone), ZP (zirconia polished), ZG (zirconia glazed), and cobalt-chromium alloy (CoCr alloy). Twenty healthy participants were instructed to carry an intraoral device with six specimens, one per group, for 24 h. Thereafter, real-time polymerase chain reaction (qPCR) and scanning electron microscopy (SEM) analyses enabled quantification and 2D view of biofilm formed on the specimens' surfaces. Kruskal-Wallis test and Dunn's post hoc analysis were used for inter-group comparison and data were presented as median (minimum-maximum). RBC specimens accumulated less bacteria, in comparison with ZG (p = 0.017) and PEEK specimens (p = 0.030), that dominated with the highest amount of adhered bacterial biofilm. PMMA, CoCr, and ZP specimens adhered more bacteria than RBC (p > 0.05), and less than ZG (p > 0.05) and PEEK (p > 0.05). The bacterial number varied considerably among participants. The obtained results enable a closer view into the susceptibility of CAD/CAM materials to microorganisms during the presence in the oral environment, which can be beneficial for a proper selection of these materials for a variety of dental restorations.

Abstract Image

评估 CAD/CAM 牙科材料上的早期细菌附着情况:一项现场研究。
本研究的目的是确定 CAD/CAM 牙科材料在口腔环境中暴露 24 小时后的早期细菌粘附性是否存在差异。根据制造商的建议制备了 120 个试样,并将其分为六组:RBC(树脂基复合材料)、PMMA(聚甲基丙烯酸甲酯)、PEEK(聚醚醚酮)、ZP(氧化锆抛光)、ZG(氧化锆上釉)和钴铬合金(钴铬合金)。之后,通过实时聚合酶链反应(qPCR)和扫描电子显微镜(SEM)分析对试样表面形成的生物膜进行量化和二维观察。组间比较采用 Kruskal-Wallis 检验和 Dunn's post hoc 分析,数据以中位数(最小值-最大值)表示。与 ZG(p = 0.017)和 PEEK(p = 0.030)试样相比,RBC 试样积聚的细菌较少,而 ZG 和 PEEK 试样附着的细菌生物膜数量最多。PMMA、CoCr和ZP试样比RBC粘附的细菌多(p > 0.05),比ZG(p > 0.05)和PEEK(p > 0.05)少。不同参与者的细菌数量差异很大。所获得的结果有助于更深入地了解 CAD/CAM 材料在口腔环境中对微生物的易感性,从而有利于正确选择这些材料用于各种牙科修复。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Odontology
Odontology 医学-牙科与口腔外科
CiteScore
5.30
自引率
4.00%
发文量
91
审稿时长
>12 weeks
期刊介绍: The Journal Odontology covers all disciplines involved in the fields of dentistry and craniofacial research, including molecular studies related to oral health and disease. Peer-reviewed articles cover topics ranging from research on human dental pulp, to comparisons of analgesics in surgery, to analysis of biofilm properties of dental plaque.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信