[Surgical Stabilization of Traumatic Multiple Rib Fractures Using Absorbable Osteosynthesis Agent(u-HA/PLLA Composite Material)].

Q4 Medicine
Hiroaki Harada, Koichi Akayama, Risa Kuboi, Satoshi Shibata
{"title":"[Surgical Stabilization of Traumatic Multiple Rib Fractures Using Absorbable Osteosynthesis Agent(u-HA/PLLA Composite Material)].","authors":"Hiroaki Harada, Koichi Akayama, Risa Kuboi, Satoshi Shibata","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>In case that met several indication criteria with 4 or more rib fractures, we performed surgical stabilization of multiple fractured ribs using a plate and screw system( Super FIXORB MX) that was made of uncalcined hydroxyapatite (u-HA)/poly-L-lactic acid (PLLA) composite material with excellent bioactivity and absorbability. We report our clinical experience of 7 cases in which this device was used. Although there is still room for further consideration of the technique and the strength of the device itself, computed tomography( CT) images taken 9 months after surgery showed that the fixative device was almost assimilated with the bone at the fracture repair site in cases where fixation was successful.</p>","PeriodicalId":17841,"journal":{"name":"Kyobu geka. The Japanese journal of thoracic surgery","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Kyobu geka. The Japanese journal of thoracic surgery","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

In case that met several indication criteria with 4 or more rib fractures, we performed surgical stabilization of multiple fractured ribs using a plate and screw system( Super FIXORB MX) that was made of uncalcined hydroxyapatite (u-HA)/poly-L-lactic acid (PLLA) composite material with excellent bioactivity and absorbability. We report our clinical experience of 7 cases in which this device was used. Although there is still room for further consideration of the technique and the strength of the device itself, computed tomography( CT) images taken 9 months after surgery showed that the fixative device was almost assimilated with the bone at the fracture repair site in cases where fixation was successful.

[利用可吸收骨合成剂(u-HA/PLLA 复合材料)对外伤性多发性肋骨骨折进行手术稳定]。
对于符合多项适应症标准且有 4 根或 4 根以上肋骨骨折的病例,我们使用一种由未煅烧羟基磷灰石(u-HA)/聚左旋乳酸(PLLA)复合材料制成的具有良好生物活性和可吸收性的钢板和螺钉系统(Super FIXORB MX)对多根骨折的肋骨进行了手术稳定。我们报告了使用该装置的 7 个病例的临床经验。尽管该技术和装置本身的强度仍有待进一步考量,但术后 9 个月的计算机断层扫描(CT)图像显示,在固定成功的病例中,固定装置几乎与骨折修复部位的骨质同化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
213
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信