Megan A Kuikman, Alannah K A McKay, Clare Minahan, Rachel Harris, Kirsty J Elliott-Sale, Trent Stellingwerff, Ella S Smith, Rachel McCormick, Nicolin Tee, Jessica Skinner, Kathryn E Ackerman, Louise M Burke
{"title":"Effect of Menstrual Cycle Phase and Hormonal Contraceptives on Resting Metabolic Rate and Body Composition.","authors":"Megan A Kuikman, Alannah K A McKay, Clare Minahan, Rachel Harris, Kirsty J Elliott-Sale, Trent Stellingwerff, Ella S Smith, Rachel McCormick, Nicolin Tee, Jessica Skinner, Kathryn E Ackerman, Louise M Burke","doi":"10.1123/ijsnem.2023-0193","DOIUrl":null,"url":null,"abstract":"<p><p>The cyclical changes in sex hormones across the menstrual cycle (MC) are associated with various biological changes that may alter resting metabolic rate (RMR) and body composition estimates. Hormonal contraceptive (HC) use must also be considered given their impact on endogenous sex hormone concentrations and synchronous exogenous profiles. The purpose of this study was to determine if RMR and dual-energy X-ray absorptiometry body composition estimates change across the MC and differ compared with HC users. This was accomplished during a 5-week training camp involving naturally cycling athletes (n = 11) and HC users (n = 7 subdermal progestin implant, n = 4 combined monophasic oral contraceptive pill, n = 1 injection) from the National Rugby League Indigenous Women's Academy. MC phase was retrospectively confirmed via serum estradiol and progesterone concentrations and a positive ovulation test. HC users had serum estradiol and progesterone concentrations assessed at the time point of testing. Results were analyzed using general linear mixed model. There was no effect of MC phase on absolute RMR (p = .877), relative RMR (p = .957), or dual-energy X-ray absorptiometry body composition estimates (p > .05). There was no effect of HC use on absolute RMR (p = .069), relative RMR (p = .679), or fat mass estimates (p = .766), but HC users had a greater fat-free mass and lean body mass than naturally cycling athletes (p = .028). Our findings suggest that RMR and dual-energy X-ray absorptiometry body composition estimates do not significantly differ due to changes in sex hormones in a group of athletes, and measurements can be compared between MC phases or with HC usage without variations in sex hormones causing additional noise.</p>","PeriodicalId":14334,"journal":{"name":"International journal of sport nutrition and exercise metabolism","volume":" ","pages":"207-217"},"PeriodicalIF":3.0000,"publicationDate":"2024-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of sport nutrition and exercise metabolism","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1123/ijsnem.2023-0193","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/1 0:00:00","PubModel":"Print","JCR":"Q2","JCRName":"NUTRITION & DIETETICS","Score":null,"Total":0}
引用次数: 0
Abstract
The cyclical changes in sex hormones across the menstrual cycle (MC) are associated with various biological changes that may alter resting metabolic rate (RMR) and body composition estimates. Hormonal contraceptive (HC) use must also be considered given their impact on endogenous sex hormone concentrations and synchronous exogenous profiles. The purpose of this study was to determine if RMR and dual-energy X-ray absorptiometry body composition estimates change across the MC and differ compared with HC users. This was accomplished during a 5-week training camp involving naturally cycling athletes (n = 11) and HC users (n = 7 subdermal progestin implant, n = 4 combined monophasic oral contraceptive pill, n = 1 injection) from the National Rugby League Indigenous Women's Academy. MC phase was retrospectively confirmed via serum estradiol and progesterone concentrations and a positive ovulation test. HC users had serum estradiol and progesterone concentrations assessed at the time point of testing. Results were analyzed using general linear mixed model. There was no effect of MC phase on absolute RMR (p = .877), relative RMR (p = .957), or dual-energy X-ray absorptiometry body composition estimates (p > .05). There was no effect of HC use on absolute RMR (p = .069), relative RMR (p = .679), or fat mass estimates (p = .766), but HC users had a greater fat-free mass and lean body mass than naturally cycling athletes (p = .028). Our findings suggest that RMR and dual-energy X-ray absorptiometry body composition estimates do not significantly differ due to changes in sex hormones in a group of athletes, and measurements can be compared between MC phases or with HC usage without variations in sex hormones causing additional noise.
期刊介绍:
The International Journal of Sport Nutrition and Exercise Metabolism (IJSNEM) publishes original scientific investigations and scholarly reviews offering new insights into sport nutrition and exercise metabolism, as well as articles focusing on the application of the principles of biochemistry, physiology, and nutrition to sport and exercise. The journal also offers editorials, digests of related articles from other fields, research notes, and reviews of books, videos, and other media releases.
To subscribe to either the print or e-version of IJSNEM, press the Subscribe or Renew button at the top of your screen.