{"title":"Monitoring the venous circulation: novel techniques and applications.","authors":"August L Longino, Katharine Martin, Ivor J Douglas","doi":"10.1097/MCC.0000000000001155","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose of review: </strong>Venous pressure is an often-unrecognized cause of patient morbidity. However, bedside assessment of PV is challenging. We review the clinical significance of venous pressure measurement, existing techniques, and introduce the Venous Excess Ultrasound (VExUS) Score as a novel approach using doppler ultrasound to assess venous pressure.</p><p><strong>Recent findings: </strong>Studies show clear associations between elevated venous pressure and adverse outcomes in critically ill patients. Current venous pressure measurement techniques include physical examination, right heart catheterization (RHC), two-dimensional ultrasound, and a variety of labor-intensive research-focused physiological maneuvers. Each of these techniques have specific shortcomings, limiting their clinical utility. To address these gaps, Beaubien-Souligny et al. introduced the VExUS Score, a novel doppler ultrasound-based method that integrates IVC diameter with doppler measurements of the hepatic, portal, and renal veins to generate a venous congestion assesment. Studies show strong correlations between VExUS score and RHC measurements, and well as an association between VExUS score and improvement in cardiorenal acute kidney injury, diuretic response, and fluid status shifts. However, studies in noncardiac populations have been small, heterogenous, and inconclusive.</p><p><strong>Summary: </strong>Early studies evaluating the use of doppler ultrasound to assess venous congestion show promise, but further research is needed in diverse patient populations and clinical settings.</p>","PeriodicalId":10851,"journal":{"name":"Current Opinion in Critical Care","volume":" ","pages":""},"PeriodicalIF":3.5000,"publicationDate":"2024-03-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Opinion in Critical Care","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MCC.0000000000001155","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose of review: Venous pressure is an often-unrecognized cause of patient morbidity. However, bedside assessment of PV is challenging. We review the clinical significance of venous pressure measurement, existing techniques, and introduce the Venous Excess Ultrasound (VExUS) Score as a novel approach using doppler ultrasound to assess venous pressure.

Recent findings: Studies show clear associations between elevated venous pressure and adverse outcomes in critically ill patients. Current venous pressure measurement techniques include physical examination, right heart catheterization (RHC), two-dimensional ultrasound, and a variety of labor-intensive research-focused physiological maneuvers. Each of these techniques have specific shortcomings, limiting their clinical utility. To address these gaps, Beaubien-Souligny et al. introduced the VExUS Score, a novel doppler ultrasound-based method that integrates IVC diameter with doppler measurements of the hepatic, portal, and renal veins to generate a venous congestion assesment. Studies show strong correlations between VExUS score and RHC measurements, and well as an association between VExUS score and improvement in cardiorenal acute kidney injury, diuretic response, and fluid status shifts. However, studies in noncardiac populations have been small, heterogenous, and inconclusive.

Summary: Early studies evaluating the use of doppler ultrasound to assess venous congestion show promise, but further research is needed in diverse patient populations and clinical settings.

监测静脉循环:新技术与应用。
审查目的:静脉压是导致患者发病的一个常被忽略的原因。然而,床旁评估静脉压具有挑战性。我们回顾了静脉压测量的临床意义、现有技术,并介绍了静脉超负荷超声(VExUS)评分,这是一种使用多普勒超声评估静脉压的新方法:研究表明,静脉压升高与危重病人的不良预后之间存在明显关联。目前的静脉压测量技术包括体格检查、右心导管检查(RHC)、二维超声和各种劳动密集型研究重点生理操作。这些技术都有各自的缺陷,限制了它们在临床上的应用。为了弥补这些不足,Beaubien-Souligny 等人推出了 VExUS 评分,这是一种基于多普勒超声的新型方法,它将 IVC 直径与肝静脉、门静脉和肾静脉的多普勒测量结果相结合,生成静脉充血评估结果。研究表明,VExUS 评分与 RHC 测量值之间存在很强的相关性,VExUS 评分与心肾急性肾损伤的改善、利尿剂反应和体液状态改变之间也存在关联。小结:评估使用多普勒超声评估静脉充血的早期研究显示了前景,但还需要在不同的患者群体和临床环境中开展进一步研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Current Opinion in Critical Care
Current Opinion in Critical Care 医学-危重病医学
CiteScore
5.90
自引率
3.00%
发文量
172
审稿时长
6-12 weeks
期刊介绍: ​​​​​​​​​Current Opinion in Critical Care delivers a broad-based perspective on the most recent and most exciting developments in critical care from across the world. Published bimonthly and featuring thirteen key topics – including the respiratory system, neuroscience, trauma and infectious diseases – the journal’s renowned team of guest editors ensure a balanced, expert assessment of the recently published literature in each respective field with insightful editorials and on-the-mark invited reviews.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信