Ryu Konno, Ryo Yamada, Mika Hanayama, Takashi Masadome
{"title":"Optical fiber chemical sensing of anionic surfactants using a microfluidic polymer chip with embedded ion-selective fluorescence optode","authors":"Ryu Konno, Ryo Yamada, Mika Hanayama, Takashi Masadome","doi":"10.1007/s44211-024-00571-1","DOIUrl":null,"url":null,"abstract":"<div><p>This study introduces a novel microfluidic polymer chip system that employs an embedded anionic surfactant (AS) ion-selective fluorescence optode (AS fluorescence optode) as a detector for measuring AS. The AS fluorescent optode comprises a lactone form of rhodamine B (L-RB) embedded in 2-nitrophenyl octyl ether plasticized poly (vinyl chloride) membrane. The AS fluorescence optode demonstrated a linear correlation between fluorescence intensity peak heights and AS concentrations within the range of less than 20 µM under optimal flow conditions. The limit of detection for AS was approximately 0.06 µM. The microfluidic system was utilized to measure AS levels in environmental samples, such as river water and tap water.</p><h3>Graphical abstract</h3><p>Photography of the microfluidic polymer chip system for the determination of anionic surfactants.</p>\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>","PeriodicalId":7802,"journal":{"name":"Analytical Sciences","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2024-04-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Sciences","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s44211-024-00571-1","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
This study introduces a novel microfluidic polymer chip system that employs an embedded anionic surfactant (AS) ion-selective fluorescence optode (AS fluorescence optode) as a detector for measuring AS. The AS fluorescent optode comprises a lactone form of rhodamine B (L-RB) embedded in 2-nitrophenyl octyl ether plasticized poly (vinyl chloride) membrane. The AS fluorescence optode demonstrated a linear correlation between fluorescence intensity peak heights and AS concentrations within the range of less than 20 µM under optimal flow conditions. The limit of detection for AS was approximately 0.06 µM. The microfluidic system was utilized to measure AS levels in environmental samples, such as river water and tap water.
Graphical abstract
Photography of the microfluidic polymer chip system for the determination of anionic surfactants.
期刊介绍:
Analytical Sciences is an international journal published monthly by The Japan Society for Analytical Chemistry. The journal publishes papers on all aspects of the theory and practice of analytical sciences, including fundamental and applied, inorganic and organic, wet chemical and instrumental methods.
This publication is supported in part by the Grant-in-Aid for Publication of Scientific Research Result of the Japanese Ministry of Education, Culture, Sports, Science and Technology.