A rare case of liner dissociation with ceramic-on-ceramic preassembled acetabular components: a case report.

IF 0.5 4区 医学 Q4 ORTHOPEDICS
J Vandenrijt, M Borstlap, E DE Smet, J Michielsen, C Heusdens, L Dossche
{"title":"A rare case of liner dissociation with ceramic-on-ceramic preassembled acetabular components: a case report.","authors":"J Vandenrijt, M Borstlap, E DE Smet, J Michielsen, C Heusdens, L Dossche","doi":"10.52628/90.1.12407","DOIUrl":null,"url":null,"abstract":"<p><p>Liner dissociations are rare but catastrophic complications after THA, requiring revision surgery. Although this complication has been well documented in THA with modular components, it has been rarely described in preassembled designs. In this report we present a rare case of liner dissociation in a ceramic-on-ceramic pre-assembled cup design. A 41-year-old man who received THA seven years ago, presented with sudden pain in the hip. Radiographic examination confirmed a small dissociation of the liner component in the acetabular shell, as well as radiolucency between the acetabular shell and the ceramic liner, and pneumarthrosis. Revision surgery was carried out six weeks following the liner dissociation. To make an accurate diagnosis, orthopaedic surgeons must be aware of the symptoms of liner dissociation.</p>","PeriodicalId":7018,"journal":{"name":"Acta orthopaedica Belgica","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta orthopaedica Belgica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.52628/90.1.12407","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Liner dissociations are rare but catastrophic complications after THA, requiring revision surgery. Although this complication has been well documented in THA with modular components, it has been rarely described in preassembled designs. In this report we present a rare case of liner dissociation in a ceramic-on-ceramic pre-assembled cup design. A 41-year-old man who received THA seven years ago, presented with sudden pain in the hip. Radiographic examination confirmed a small dissociation of the liner component in the acetabular shell, as well as radiolucency between the acetabular shell and the ceramic liner, and pneumarthrosis. Revision surgery was carried out six weeks following the liner dissociation. To make an accurate diagnosis, orthopaedic surgeons must be aware of the symptoms of liner dissociation.

陶瓷预组装髋臼组件衬垫分离的罕见病例:病例报告。
衬垫脱落是一种罕见但却严重的 THA 并发症,需要进行翻修手术。虽然这种并发症在使用模块化组件的 THA 中已有大量记录,但在预组装设计中却很少见。在本报告中,我们介绍了一例罕见的预组装陶瓷髋臼杯衬垫解离病例。一名 41 岁的男子七年前接受过 THA 手术,突然出现髋部疼痛。影像学检查证实,髋臼壳内的衬垫组件有小部分脱离,髋臼壳和陶瓷衬垫之间有放射性渗出,并伴有气胸。在衬垫分离六周后,进行了翻修手术。为了做出准确的诊断,矫形外科医生必须了解衬垫分离的症状。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Acta orthopaedica Belgica
Acta orthopaedica Belgica 医学-整形外科
CiteScore
0.70
自引率
0.00%
发文量
58
审稿时长
4-8 weeks
期刊介绍: Information not localized
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信