Vesa Vuorinen, Reijo Kouhia, Mauno Könönen, Jorma K. Kivilahti
{"title":"Bonding of ceramics to silver-coated titanium—A combined theoretical and experimental study","authors":"Vesa Vuorinen, Reijo Kouhia, Mauno Könönen, Jorma K. Kivilahti","doi":"10.1002/jbm.b.35407","DOIUrl":null,"url":null,"abstract":"<p>It would be very beneficial to have a method for joining of ceramics to titanium reliably. Although several techniques have been developed and tested to prevent extensive interfacial chemical reactions in titanium-ceramic systems, the main problem of the inherent brittleness of interfaces was still unsolved. To overcome this problem also in dental applications, we decided to make use of an interlayer material that needs to meet the following requirements: First, it has to be biocompatible, second, it should not melt below the bonding temperatures, and third, it should not react too strongly with titanium, so that its plasticity will be maintained. Considering possible material options only the metals: gold, platinum, palladium, and silver, fulfill the first and second requirements. To find out—without an extensive experimental testing program—which of the four metals fulfills the third requirement best, the combined thermodynamic and reaction kinetic modeling was employed to evaluate how many and how thick reaction layers are formed between the interlayer metals and titanium. With the help of theoretical modeling, it was shown that silver fulfills the last requirement best. However, before starting to test experimentally the effect of the silver layer on the mechanical integrity of dental ceramic/Ag/Ti joints it was decided to make use of mechanical analysis of the three-point bending test, the result of which indicated that the silver layer increases significantly the bond strength of the joints. This result encouraged us to develop a new technique for plating silver on titanium. Subsequently, we executed numerous three-point bending tests, which demonstrated that silver-plated titanium-ceramic joints are much stronger than conventional titanium-ceramic joints. Hence, it can be concluded that the combined thermodynamic, reaction kinetic, and mechanical modeling method can also be a very valuable tool in medical research and development work.</p>","PeriodicalId":15269,"journal":{"name":"Journal of biomedical materials research. Part B, Applied biomaterials","volume":null,"pages":null},"PeriodicalIF":3.2000,"publicationDate":"2024-04-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/jbm.b.35407","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of biomedical materials research. Part B, Applied biomaterials","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jbm.b.35407","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
It would be very beneficial to have a method for joining of ceramics to titanium reliably. Although several techniques have been developed and tested to prevent extensive interfacial chemical reactions in titanium-ceramic systems, the main problem of the inherent brittleness of interfaces was still unsolved. To overcome this problem also in dental applications, we decided to make use of an interlayer material that needs to meet the following requirements: First, it has to be biocompatible, second, it should not melt below the bonding temperatures, and third, it should not react too strongly with titanium, so that its plasticity will be maintained. Considering possible material options only the metals: gold, platinum, palladium, and silver, fulfill the first and second requirements. To find out—without an extensive experimental testing program—which of the four metals fulfills the third requirement best, the combined thermodynamic and reaction kinetic modeling was employed to evaluate how many and how thick reaction layers are formed between the interlayer metals and titanium. With the help of theoretical modeling, it was shown that silver fulfills the last requirement best. However, before starting to test experimentally the effect of the silver layer on the mechanical integrity of dental ceramic/Ag/Ti joints it was decided to make use of mechanical analysis of the three-point bending test, the result of which indicated that the silver layer increases significantly the bond strength of the joints. This result encouraged us to develop a new technique for plating silver on titanium. Subsequently, we executed numerous three-point bending tests, which demonstrated that silver-plated titanium-ceramic joints are much stronger than conventional titanium-ceramic joints. Hence, it can be concluded that the combined thermodynamic, reaction kinetic, and mechanical modeling method can also be a very valuable tool in medical research and development work.
期刊介绍:
Journal of Biomedical Materials Research – Part B: Applied Biomaterials is a highly interdisciplinary peer-reviewed journal serving the needs of biomaterials professionals who design, develop, produce and apply biomaterials and medical devices. It has the common focus of biomaterials applied to the human body and covers all disciplines where medical devices are used. Papers are published on biomaterials related to medical device development and manufacture, degradation in the body, nano- and biomimetic- biomaterials interactions, mechanics of biomaterials, implant retrieval and analysis, tissue-biomaterial surface interactions, wound healing, infection, drug delivery, standards and regulation of devices, animal and pre-clinical studies of biomaterials and medical devices, and tissue-biopolymer-material combination products. Manuscripts are published in one of six formats:
• original research reports
• short research and development reports
• scientific reviews
• current concepts articles
• special reports
• editorials
Journal of Biomedical Materials Research – Part B: Applied Biomaterials is an official journal of the Society for Biomaterials, Japanese Society for Biomaterials, the Australasian Society for Biomaterials, and the Korean Society for Biomaterials. Manuscripts from all countries are invited but must be in English. Authors are not required to be members of the affiliated Societies, but members of these societies are encouraged to submit their work to the journal for consideration.